Plate Heat Exchanger for Boiler ZWBC 30-2 C 23 Ref. 87161066850
The Junkers Cerapur Comfort ZWBC boilers use the heat exchanger for boiler ZWBC 30-2 C 23, which is responsible for transferring heat from the primary circuit to the domestic hot water instantly. When this part fails, you will notice that the water comes out lukewarm or with fluctuating temperature, and the flow of DHW decreases. It is compatible with models such as ZWBC24-2C, ZWBC28-2C, ZWBC30-2C, among others. It should be replaced when you start experiencing these symptoms.
VAT included
Consult via WhatsAppJunkers boilers compatible with reference 87161066850
Plate heat exchanger with reference 87161066850. 11 verified compatibilities: ZWBC24-2C and ZWBC28-2C.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Junkers ZWBC24-2C | Cerapur Comfort (ZWBC) | Contrasted |
| Junkers ZWBC28-2C | Cerapur Comfort (ZWBC) | Contrasted |
| Junkers ZWBC30-2C | Cerapur Comfort (ZWBC) | Contrasted |
| Junkers ZWB32-2A | Cerapur Comfort (ZWB/ZWBE) | Contrasted |
| Junkers ZWB32-2E | Cerapur Comfort (ZWB/ZWBE) | Contrasted |
| Junkers ZWB37-2E | Cerapur Comfort (ZWB/ZWBE) | Contrasted |
| Junkers ZWB42-2E | Cerapur Comfort (ZWB/ZWBE) | Contrasted |
| Junkers ZWBE30-3C | Cerapur Comfort (ZWB/ZWBE) | Contrasted |
| Junkers ZWBE37-2A | Cerapur Comfort (ZWB/ZWBE) | Contrasted |
| Junkers ZWBE42-2A | Cerapur Comfort (ZWB/ZWBE) | Contrasted |
| Junkers ZWN30-8MFA | Junkers ZWN | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if the ref. 87161066850 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 87161066850. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the heat exchanger 87161066850 resolves.
The plate heat exchanger transfers heat to the domestic hot water. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
There is a drip or moisture under the boiler that is not clear where it is coming from.
Cause: The heat exchanger plates are not sealed properly, allowing water to escape through the body of the part or its gasket.
Dry the area, leave paper underneath for a while with the boiler running, and check if the dripping originates right there.
- 02
The boiler is taking longer to provide hot water and it seems to be consuming more than before.
Cause: The plates with accumulated scale hinder heat exchange, causing the boiler to work harder.
Time how long it takes for hot water to come out and compare it with the boiler filter when it is clean, to rule out that the delay comes from there.
- 03
The hot water comes out in bursts, alternating between cold and hot without maintaining a stable temperature.
Cause: Partially clogged plates due to scale cause an irregular water flow, resulting in temperature fluctuations.
Open the tap to maximum flow and then to minimum: if the fluctuation improves with less flow, it indicates a partial obstruction in the plates.
- 04
The pressure in the system rises on its own over the days.
Cause: An internal micro-leak in the heat exchanger allows water to pass from one circuit to another, increasing the pressure.
Note the pressure before and after using hot water for a couple of days, without touching the filling valve.
Fault codes from Junkers that this part resolves.
| Code | Fault | Diagnosis and solution |
|---|---|---|
| E2 | Faulty supply temperature sensor | The supply temperature sensor is faulty. This may cause the boiler to malfunction. If you notice that the hot water does not reach the desired temperature, it could be that the plate heat exchanger is affecting the water circulation. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Plate heat exchanger data sheet Junkers 87161066850
- Catalogue reference
- 87161066850
- Brand
- Junkers
- Type of part
- Plate heat exchanger
- Units in stock
- 4 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- maximum pressure
- 10 bar
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Junkers ZWN30-8MFA manual (PDF)Document © Junkers, provided as a technical reference.