Thermomanometer for Vega 20 AIM/AIFM and 24 AIM/AIFM boiler
Analog thermometer with a copper bulb and threaded connector at the end of the cable, which is installed on the boiler panel. The dial shows the water temperature (up to approximately 140 °C, with markings every 20°) and the circuit pressure (0-4 bar, with a red mark at 3 bar). It should be checked or replaced if the needle does not respond, the glass is broken, or there is a leak at the connector.
VAT included
Consult via WhatsAppBaxi Roca boilers compatible with reference 122621983
Pressure gauge with reference 122621983. Four confirmed compatibilities: Vega 20 AIFM and Vega 20 AIM.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Baxi Roca Vega 20 AIFM | Baxi Roca Vega | Contrasted |
| Baxi Roca Vega 20 AIM | Baxi Roca Vega | Contrasted |
| Baxi Roca Vega 24 AIFM | Baxi Roca Vega | Contrasted |
| Baxi Roca Vega 24 AIM | Baxi Roca Vega | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if the reference 122621983 is the part for your boiler.
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 122621983. If it is not visible, do not identify the part by its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the manometer 122621983 resolves.
The manometer shows the pressure of the boiler circuit. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The pressure gauge remains fixed at a value and does not rise or fall even when the circuit pressure changes.
Cause: The internal mechanism of the thermomanometer gets stuck or loses tightness and stops transferring the actual pressure to the needle.
Gently tap the gauge and bleed a radiator to see if the needle reacts before declaring it faulty.
- 02
A ring of moisture or water droplets appears around the thread where the sensor is connected.
Cause: The threaded connector of the copper bulb loses tightness over time and the water from the circuit escapes from there.
Dry the area well, tighten the fitting carefully, and check again in a few hours to see if the leak reappears before replacing the part.
- 03
The gauge is scratched, fogged, or has a broken glass, making it impossible to read either pressure or temperature.
Cause: The glass is an exposed part, and a blow or the passage of time deteriorates it without affecting the rest of the installation.
Check if the damage is only to the glass by moving the needle by touch, or if it is also blocked inside.
- 04
The customer believes that the boiler has lost pressure, but it starts and heats normally.
Cause: A thermometer only provides information; it does not stop the operation of the boiler, so an incorrect reading does not necessarily indicate a real pressure fault.
If the rest of the boiler is working well, first suspect the pressure gauge before adjusting the system pressure.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Baxi Roca pressure gauge 122621983
- Catalogue reference
- 122621983
- Brand
- Baxi Roca
- Type of part
- Pressure gauges - Aquastats
- Units in stock
- 3 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Temperature scale (dial)
- 0-140 °C approx. (marks at 0, 20, 40, 60, 80, 100, 120)
- Pressure gauge (dial)
- 0-4 bar, red mark at 3 bar
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Baxi Roca Vega 24 AIFM Manual (PDF)Document © Baxi Roca, provided as a technical reference.