Saunier Duval Pressure Sensor Ref. 0020016532

Saunier Duval Pressure Sensor Ref. 0020016532

The pressure sensor Saunier Duval is a sensor that measures the water pressure in the boiler circuit. Its function is to send the pressure reading to the control board. When it fails, you may notice blockages or incorrect readings, which can lead to a fault code F9: water pressure detector failure. This sensor is compatible with boilers from the ThemaClassic range, such as the model F 25 E, as well as with the model F 35 E from the Isofast range, among others. A technician must confirm through diagnosis whether replacement is necessary when the mentioned symptoms are detected.

Type of part
Pressure sensors
Catalogue reference
S5720500
Warranty
1 year
VAT included Stock · 1 unit
Compatibility

Saunier Duval boilers compatible with reference S5720500

Pressure sensor with reference S5720500. Six confirmed compatibilities: F 25 E and C 25 E.

Proven compatibility

Boiler modelFamilyVerification
Saunier Duval F 25 EThemaClassicContrasted
Saunier Duval C 25 EThemaClassicContrasted
Saunier Duval F 30 EThemaClassicContrasted
Saunier Duval C 24 E1ThemaClassicContrasted
Saunier Duval F 24 E1ThemaClassicContrasted
Saunier Duval F 35 EIsofastContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. S5720500 is the part for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference S5720500. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms that require diagnosis in the pressure switch S5720500

The pressure sensor measures the water pressure for the electronics. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler shuts down with a low pressure warning just after starting, even though the pressure gauge reads correctly.

    Cause: The sensor sends a low pressure signal to the PCB, which interrupts the ignition cycle.

    Note if the cut always occurs a few seconds after starting and compare it with the reading of the analog manometer before changing the part.

  • 02

    The pressure reading on the display changes by itself, unrelated to the filling or the use of the heating.

    Cause: The sensor has a degraded signal, sending erratic readings to the control board.

    Leave the boiler off for a few minutes and check if the reading remains stable; if it varies without reason, suspect the sensor.

  • 03

    The boiler gets locked due to pressure and does not respond to reset until it is turned off and back on again.

    Cause: A sensor that gets 'stuck' on an incorrect reading may require a reset of the PCB to attempt to read again.

    Before replacing it, try a complete reset (turn it off, wait, and turn it back on) and check if the fault reappears immediately.

  • 04

    The installer confirms that the installation is properly filled and bled, but the boiler continues to indicate a pressure fault.

    Cause: If the sensor does not provide accurate information to the PCB, the warning persists even though the actual pressure in the circuit is correct.

    Check the actual pressure of the circuit with an external manometer before ruling out a filling issue and focusing on the sensor.

Fault codes Saunier Duval that require diagnosis

CodeFaultTechnical checks
F9Water pressure sensor fault.The pressure transducer S5720500 delivers an absent/out-of-range signal or does not reach the PCB, the electronics interpret an abnormal pressure and lock with F9; verify by measuring the sensor signal and the harness/wiring and comparing with an external manometer.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for Saunier Duval pressure sensor S5720500

Catalogue reference
S5720500
Uniclima internal SKU
CPCSDTCFAS24
Brand
Saunier Duval
Type of part
Pressure sensors
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

Part code (label)
0020016532
Frequently Asked Questions

Frequently asked questions about the pressure sensor S5720500

Does this pressure sensor from Saunier Duval work for a boiler from the ThemaClassic range?
Yes, it is compatible with the models from the ThemaClassic range: F 25 E, C 25 E, F 30 E, C 24 E1, and F 24 E1.
What fault of the Isofast F 35 E does this pressure switch solve?
It should be checked when the boiler gives incorrect pressure readings or gets blocked for this reason; it measures the water circuit pressure and sends it to the PCB. Replacement requires a technical diagnosis.
Is it the same part for the ThemaClassic range and the Isofast?
Yes, the pressure sensor Saunier Duval with reference 0020016532 is compatible with the models of both mentioned ranges.
How many models are compatible with this pressure switch?
This pressure switch is compatible with a total of 6 models.
What fault code is documented for this pressure sensor?
The documented fault code for this product is F9.

Spare parts related to Saunier Duval ThemaClassic

Entrega calculada por destino Delivery time shown at checkout
1-year warranty reviewed and tested
14-day return uninstalled parts
Technical support we verify your model
Saunier Duval Pressure Sensor Ref. 0020016532