Air Pressure Switch Boiler Ferroli - Ref. 605.99618
When you turn on the tap or the heating, the air pressure switch of the Ferroli boiler - Ref. 605.99618 is responsible for checking the necessary air pressure for its operation. This part is crucial for the boiler to start correctly; if it fails, you will notice that the boiler does not ignite or gets locked, even if the actual pressure is adequate. It is compatible with Ferroli models such as Nef Vent CE, Innox B CE, and Era F 32 BS 60, among others. A technician must confirm through diagnosis whether it is necessary to replace it when you experience these symptoms or if the part shows visible damage.
- Type of part
- Pressure switches
- Status
- Refurbished
- Catalogue reference
- I39800140
- Warranty
- 1 year
Huba boilers compatible with reference I39800140
Pressure switch with reference I39800140. Five confirmed compatibilities: Nef Vent CE and Nef Vent E CE.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Huba Nef Vent CE | Ferroli | Contrasted |
| Huba Nef Vent E CE | Ferroli | Contrasted |
| Huba Innox B CE | Ferroli | Contrasted |
| Huba Era F 32 BS 60 | Ferroli | Contrasted |
| Huba Master Vent | Ferroli | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if the reference I39800140 is the part for your boiler.
The part reference, model, and equipment revision must be verified against the manufacturer's documentation.
- Find the reference printed on the installed part and check whether it matches the catalogue reference I39800140. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms that require diagnosis in the pressure switch I39800140
The pressure switch controls the air or water pressure to authorize operation. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler does not ignite and remains on standby, as if it does not finish starting up.
Cause: The pressure switch acts as a safety device: if it does not detect the correct air pressure difference, it does not allow ignition.
Check that the flue outlet to the outside is not obstructed by dirt, snow, or any object, and that the intake pipe is not crushed.
- 02
The fan starts normally, but the ignition cycle does not continue.
Cause: The electrical contact of the pressure switch does not change even though the air pressure generated by the fan is correct.
Measure with a multimeter that the pressure switch changes state when the fan is running.
- 03
The startup faults are intermittent; they do not occur all the time.
Cause: An air pressure at the switching limit can cause the pressure switch to fail intermittently depending on the conditions.
Check that the intake and exhaust ducts do not have long sections, added elbows, or dirty grilles that reduce the draft.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Huba I39800140 pressure switch data sheet
- Catalogue reference
- I39800140
- Uniclima internal SKU
- PCRR20F
- Brand
- Huba
- Type of part
- Pressure switches
- Units in stock
- 3 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Part data and available documentation
Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.
- Component code
- 605.99618
- Setpoint
- 47 Pa
- Differential
- Δ12 Pa
- Contact electric charge
- 1(0.5)A / 250V~
- Test gas
- G20
- Batch code
- FNMFAF