Cointra E-20 I Honeywell (Yamatake) Air Pressure Switch Ref. CN76706664

Cointra E-20 I Honeywell (Yamatake) Air Pressure Switch Ref. CN76706664

Stock · 4 units

Air pressure switch for Cointra boilers E-20 I and E-20 L. Manufactured by Honeywell (Yamatake), code C6065A1473:2 printed on the part, different from the catalog reference CN76706664. Set to 0.95 mbar, maximum 6 mbar. It checks the air pressure before allowing ignition. It is replaced when the boiler locks due to draft failure or does not ignite with the fan running.

VAT included

Compatibility

Cointra boilers compatible with reference CN76706664

Pressure switch with reference CN76706664. Two confirmed compatibilities: E-20 I and E-20 L.

Proven compatibility

Boiler modelFamilyVerification
Cointra E-20 ICointraContrasted
Cointra E-20 LCointraContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. CN76706664 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference CN76706664. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the pressure switch CN76706664 resolves.

The pressure switch controls the air or water pressure to authorize operation. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler attempts to ignite, the fan starts, but it stops without lighting the burner.

    Cause: The pressure switch does not close the air contact, and the control unit interrupts the ignition cycle for safety.

    Check that the silicone tubes of the pressure switch are not disconnected, bent, or have condensed water inside.

  • 02

    The display shows a fault code related to the draft or the pressure switch.

    Cause: It's the typical warning when the control unit does not receive the air pressure signal within the expected time.

    Check that the fan rotates freely and without any unusual noise before assuming it is the pressure switch.

  • 03

    The boiler shuts off by itself during operation, with the fan still running.

    Cause: A pressure switch with an unstable contact can open during operation, and the control unit interprets this as a loss of draft.

    Check the flue for any external obstruction (nest, snow, dirt) that might reduce the draft.

  • 04

    Ignitions that sometimes work well and other times stop halfway, with no clear pattern.

    Cause: A microswitch with dirty or oxidized contacts switches irregularly depending on vibration or humidity.

    Try turning it on several times in a row and note if it always fails at the same point in the cycle before replacing the part.

Fault codes for Cointra that this part resolves.

CodeFaultDiagnosis and solution
ERROR2Fault due to issues related to the air pressure switch.The air pressure switch does not switch when the fan starts due to lack of depression/draught, obstruction, or fault/wiring of the pressure switch itself; verify that it switches (continuity/manometer) when the fan starts and check silicone tubes and K10 selection/wiring.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Datasheet for the Cointra CN76706664 pressure switch

Catalogue reference
CN76706664
Brand
Cointra
Type of part
Pressure switches
Units in stock
4 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

component code
C6065A1473:2
manufacturer
Honeywell (Yamatake)
voltage
250V~
capacitor
1.5(0.5) μF
set pressure
0.95 mbar
maximum pressure
6 mbar
batch code
0208F
CE code
CE-0063AP3085/1
manufacturing origin
Made in China
Before purchasing
  • The code printed on the part (C6065A1473:2) is different from the catalog reference (CN76706664); the latter is Cointra's own numbering, not Honeywell's code.
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the pressure switch CN76706664

Is the pressure switch of the Cointra E-20 I manufactured by Honeywell?
Yes, the part has the Honeywell (Yamatake) code C6065A1473:2 printed on the label.
Why does the part code C6065A1473:2 not match the reference CN76706664 for the Cointra E-20 I?
The printed code is Honeywell's manufacturing code; the reference CN76706664 is Cointra's own catalog numbering.
Is this pressure switch suitable for a Cointra E-20 L?
Yes, the Cointra E-20 L is on the list of compatible boilers along with the E-20 I.
At what air pressure does the pressure switch of the Cointra E-20 I switch?
It is set to 0.95 mbar and allows a maximum of 6 mbar.
What fault indicates that the pressure switch of the Cointra E-20 I needs to be replaced?
It is replaced when the boiler locks due to a draft fault or does not ignite with the fan running.

Spare parts related to Cointra Cointra

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model