Honeywell Pressure Switch C6065FH1052:2 - Fondital Nias Dual BTFS Ref. 6PRESSAC00

Honeywell Pressure Switch C6065FH1052:2 - Fondital Nias Dual BTFS Ref. 6PRESSAC00

Stock · 5 units

Honeywell pressure switch (Yamatake-Honeywell) model C6065FH1052:2, with NC/NO microswitch and contact capacitor of 1.5(0.5) µF at 250V~. Set at 0.60 mbar with a maximum pressure of 6 mbar, CE-0063AP3085/1 certified. It is used in Fondital boilers of the Dual BTFS series and compatibles. It is replaced when it stops switching the contact or the boiler does not detect the pressure correctly.

VAT included

Compatibility

Fondital boilers compatible with reference 6PRESSAC00

Pressure switch with reference 6PRESSAC00. Ten confirmed compatibilities: BTFS 24 and BTFS 28.

Proven compatibility

Boiler modelFamilyVerification
Fondital BTFS 24Nias Dual Line TechContrasted
Fondital BTFS 28Nias Dual Line TechContrasted
Fondital BTFS 32Nias Dual Line TechContrasted
Fondital BTN 24Nias Dual Line TechContrasted
Fondital BTN 28Nias Dual Line TechContrasted
Fondital BTN 32Nias Dual Line TechContrasted
Fondital CTFS 24Tahiti Dual LineContrasted
Fondital CTFS 28Tahiti Dual LineContrasted
Fondital CTFS 32Tahiti Dual LineContrasted
Fondital RTFS 24Tahiti Dual LineContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 6PRESSAC00 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 6PRESSAC00. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the pressure switch 6PRESSAC00 resolves.

The pressure switch controls the air or water pressure to authorize operation. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler tries to ignite, you can hear the fan start, and after a few seconds, it stops without producing a flame.

    Cause: The air pressure switch does not close the contact that confirms there is sufficient draft, and the control board cuts the cycle before opening the gas.

    Start the boiler and listen to see if the fan reaches normal speed before suspecting the pressure switch.

  • 02

    The panel indicates a ventilation or air pressure fault as soon as you press reset.

    Cause: The pressure switch interprets that the vacuum generated by the fan does not reach the required minimum.

    Check the flue pipe outside for obstructions, nests, or blocked grilles before replacing the part.

  • 03

    The silicone tubes connecting the pressure switch to the air circuit are hanging down or cracked.

    Cause: Without a sealed pressure intake, the pressure switch cannot measure the actual depression and blocks the boiler even if the fan is working properly.

    Visually check that both silicone tubes are still connected and free of cracks before ordering the spare part.

  • 04

    The fault appears only when it's windy or raining, and disappears in calm weather.

    Cause: A gust of wind at the outlet terminal can alter the pressure seen by the pressure switch and simulate a fault.

    Note if the lockout coincides with strong wind; if so, check the external terminal before the pressure switch.

Fault codes from Fondital that this part resolves.

CodeFaultDiagnosis and solution
E04Lockout due to insufficient pressure in the installation (intervention of the water pressure switch).The pressure switch 6PRESSAC00 opens or does not switch when the circuit pressure drops or the switch itself is faulty; to verify, measure the actual system pressure and check with a multimeter the continuity/switching of the pressure switch during filling.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Fondital 6PRESSAC00 pressure switch datasheet

Catalogue reference
6PRESSAC00
Brand
Fondital
Type of part
Pressure switches
Units in stock
5 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Model
C6065FH1052:2
Voltage
250V~
Set pressure
0.60 mbar
Maximum pressure
6 mbar
Contact capacitor
1.5(0.5) µF 250V~
CE certification
CE-0063AP3085/1
Batch code/date
0020D
Manufacturer (literal marking)
Yamatake-Honeywell
Frequently Asked Questions

Frequently asked questions about the pressure switch 6PRESSAC00

Is the Honeywell C6065FH1052:2 pressure switch compatible with the Fondital Nias Dual BTFS 24-28-32?
Yes, it is compatible with the Nias Dual BTFS 24, BTFS 28, and BTFS 32 series.
Does this pressure switch work for the Fondital Flores Dual CTFS?
Yes, it is listed as compatible with the CTFS variant of Flores Dual.
What pressure is the Honeywell C6065FH1052:2 pressure switch set to?
It is set to 0.60 mbar, with an allowable maximum of 6 mbar.
What certification does the Honeywell C6065FH1052:2 pressure switch have?
It is CE certified-0063AP3085/1.
How many models are compatible with the Honeywell C6065FH1052:2 pressure switch?
This pressure switch is compatible with a total of 10 models.
What is the reference for the Honeywell C6065FH1052:2 pressure switch for the Fondital Nias Dual BTFS?
The reference is PCFNBTFS.

Spare parts related to Fondital Nias Dual Line Tech

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Honeywell Pressure Switch C6065FH1052:2 - Fondital Nias Dual BTFS Ref. 6PRESSAC00