Caleffi 3 Bar Safety Valve - Ferroli Domiproject F24 and Vokera HE - Ref. 10025055
Caleffi safety valve, set at 3 bar and with a maximum working temperature of 110°C. It protects the heating circuit by releasing water if the pressure rises above the set point. It carries the CE notified body marking 1116. Compatible with Ferroli Domiproject F24 and several Vokera models from the HE range.
VAT included
Consult via WhatsAppFerroli boilers compatible with reference 10025055
Safety valve with reference 10025055. Eight verified compatibilities: DOMIproject F24 and Compact 25 HE.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Ferroli DOMIproject F24 | Ferroli | Contrasted |
| Ferroli Compact 25 HE | Vokera | Contrasted |
| Ferroli Compact 29 HE | Vokera | Contrasted |
| Ferroli Compact 35 HE | Vokera | Contrasted |
| Ferroli Linea 25 HE | Vokera | Contrasted |
| Ferroli Procombi 85 HE | Vokera | Contrasted |
| Ferroli Sabre 25 HE | Vokera | Contrasted |
| Ferroli Sabre 29 HE | Vokera | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if the ref. 10025055 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 10025055. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the safety valve 10025055 resolves
The safety valve releases pressure when the circuit exceeds its setting. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The valve is leaking continuously from the discharge pipe, whether the boiler is cold or hot.
Cause: The valve seat does not seal properly, usually due to a particle of scale or dirt, or because the circuit is actually operating above 3 bar.
Check the pressure on the manometer with the boiler cold: if it already shows close to 3 bar, first check the expansion vessel and the filling valve.
- 02
When heating, the pressure gauge needle rises and the valve starts to bleed water.
Cause: If the expansion vessel does not absorb the expansion of the water, all that excess pressure has to be released by the safety valve.
Check the air pressure of the expansion vessel with the boiler cold and depressurized before declaring the valve faulty.
- 03
The test lever is activated and no water comes out.
Cause: The internal mechanism can seize up over time if it has never been tested, due to limescale or lack of use.
Try to activate it manually a couple of times; if it still doesn't bleed with high pressure, then it does need to be replaced.
- 04
The circuit gradually loses pressure and no leaks are visible on the floor or in the radiators.
Cause: The water comes out through the discharge pipe of the valve and goes directly to the drain, without leaving any puddle in sight.
Follow the discharge pipe to its outlet and look for signs of scale or recent moisture before concluding that it is the valve.
Fault codes for Ferroli that this part resolves.
| Code | Fault | Diagnosis and solution |
|---|---|---|
| AL 8 | Pressure below the limit | The boiler detects a pressure lower than the calibration limit of the pressure switch. This may affect the performance of the boiler. If the safety valve is not operational, the pressure will not be maintained correctly. Check the condition of the valve and the connections. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Ferroli safety valve 10025055
- Catalogue reference
- 10025055
- Brand
- Ferroli
- Type of part
- Safety valves
- Units in stock
- 5 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Manufacturer (engraved: "CALEFFI Hydronic Solutions")
- Caleffi
- Setpoint
- 3 bar
- Nominal Pressure (PN)
- PN 10
- Maximum temperature
- 110°C
- Notified body (CE marking)
- CE 1116
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Ferroli Linea 25 HE Manual (PDF)Document © Ferroli, provided as a technical reference.