3 Bar Safety Valve Cointra ED 21 I - Ref. 9158449

3 Bar Safety Valve Cointra ED 21 I - Ref. 9158449

Safety valve set at 3 bar, with the code 9158449 engraved on the body, matching the catalog reference. Compatible with Cointra boilers from the ED 21, SP 21, SP 24, SP 27, SPA 27, SPI 21, and Supra Compact 21 ranges. Releases water from the circuit if the pressure exceeds the setting, preventing overpressure. The replacement requires first confirming the fault of the part through technical diagnosis, even when it drips continuously or loses calibration.

Type of part
Safety valves
Catalogue reference
9158449
Warranty
1 year
VAT included Stock · 3 units
Compatibility

Cointra boilers compatible with reference 9158449

Safety valve with reference 9158449. 11 verified compatibilities: ED 21 I and ED 21 EI.

Proven compatibility

Boiler modelFamilyVerification
Cointra ED 21 IEdycoContrasted
Cointra ED 21 EIEdycoContrasted
Cointra SP 21 ISupraContrasted
Cointra SP 21 EISupraContrasted
Cointra SP 24 ISupraContrasted
Cointra SP 27 EISupraContrasted
Cointra SPA 27 EISupraContrasted
Cointra SPC 21 EI / Supra Compact 21 EISupraContrasted
Cointra SPI 21 IEuropeContrasted
Cointra SPI 21 EIEuropeContrasted
Cointra SPI 27 EIEuropeContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if the ref. 9158449 is the part for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 9158449. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms that require diagnosis in the safety valve 9158449

The safety valve releases pressure when the circuit exceeds its setting. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    It continuously drips from the discharge pipe, even when the boiler is off.

    Cause: The valve is set to 3 bar; if the circuit pressure is lower and it continues to drip, the seat is not sealing properly.

    Measure the cold pressure: if it is below 2.5 bar and the dripping persists, it is not a system pressure issue.

  • 02

    After bleeding or activating the test lever, it continues to lose water.

    Cause: Dirt or limescale on the seat can prevent it from closing completely.

    Repeat the bleeding, letting the water run a couple of times before changing the gas valve.

  • 03

    The circuit is losing pressure and no leaks are visible in the radiators or pipes.

    Cause: A valve that drips intermittently can release pressure without leaving visible puddles.

    Check the expansion vessel: if it has lost air, the pressure rises too much when heating and it may open the valve without being damaged.

  • 04

    The pressure needs to be topped up more frequently than usual.

    Cause: Every time the valve is opened, even briefly, water is lost and the pressure drops.

    Note if the pressure loss coincides with moments of greater heating; this suggests a problem with the expansion vessel rather than with the valve.

Fault codes Cointra that require diagnosis

CodeFaultTechnical checks
E09High pressure alarmAn alarm has been triggered due to high pressure in the system. This can be dangerous and requires immediate attention. Check the valves and the condition of the system to determine if the safety valve is failing.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Cointra safety valve 9158449

Catalogue reference
9158449
Uniclima internal SKU
VSCED21I
Brand
Cointra
Type of part
Safety valves
Units in stock
3 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

Setpoint
3 bar
Code engraved on the part
9158449
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the safety valve 9158449

Is this valve suitable for a Cointra SP 24 I?
Yes, it is listed as compatible with SP 24 I, as well as ED 21, SP 21, SP 27, SPA 27, SPI 21, and Supra Compact 21.
What pressure is the valve of the Cointra SPA 27 EI set to?
A 3 bar, read on the dial of the red cover.
Does reference 9158449 match the code engraved on the part?
Yes, the same code is engraved on the body and matches the catalog.
When should this valve be replaced in a Cointra Supra Compact 21 EI?
The technical diagnosis must confirm that it is necessary to replace it, even when it is leaking continuously or losing calibration.
Entrega calculada por destino Delivery time shown at checkout
1-year warranty reviewed and tested
14-day return uninstalled parts
Technical support we verify your model
3 Bar Safety Valve Cointra ED 21 I - Ref. 9158449