Safety valve set to 3 bar, with the code 9158449 engraved on the body, matching the catalog reference. Compatible with Cointra boilers from the ED 21, SP 21, SP 24, SP 27, SPA 27, SPI 21, and Supra Compact 21 ranges. Releases water from the circuit if the pressure exceeds the setting, preventing overpressure. It should be replaced when it drips continuously or loses calibration.

VAT included

Compatibility

Cointra boilers compatible with reference 9158449

Safety valve with reference 9158449. 11 verified compatibilities: ED 21 I and ED 21 EI.

Proven compatibility

Boiler modelFamilyVerification
Cointra ED 21 IEdycoContrasted
Cointra ED 21 EIEdycoContrasted
Cointra SP 21 ISupraContrasted
Cointra SP 21 EISupraContrasted
Cointra SP 24 ISupraContrasted
Cointra SP 27 EISupraContrasted
Cointra SPA 27 EISupraContrasted
Cointra SPC 21 EI / Supra Compact 21 EISupraContrasted
Cointra SPI 21 IEuropeContrasted
Cointra SPI 21 EIEuropeContrasted
Cointra SPI 27 EIEuropeContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if the ref. 9158449 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 9158449. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the safety valve 9158449 resolves.

The safety valve releases pressure when the circuit exceeds its setting. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    It continuously drips from the discharge pipe, even when the boiler is off.

    Cause: The valve is set to 3 bar; if the circuit pressure is lower and it continues to drip, the seat is not sealing properly.

    Measure the cold pressure: if it is below 2.5 bar and the dripping persists, it is not a system pressure issue.

  • 02

    After bleeding or activating the test lever, it continues to lose water.

    Cause: Dirt or limescale on the seat can prevent it from closing completely.

    Repeat the bleeding, letting the water run a couple of times before changing the gas valve.

  • 03

    The circuit is losing pressure and no leaks are visible in the radiators or pipes.

    Cause: A valve that drips intermittently can release pressure without leaving visible puddles.

    Check the expansion vessel: if it has lost air, the pressure rises too much when heating and it may open the valve without being damaged.

  • 04

    The pressure needs to be topped up more frequently than usual.

    Cause: Every time the valve is opened, even briefly, water is lost and the pressure drops.

    Note if the pressure loss coincides with moments of greater heating; this suggests a problem with the expansion vessel rather than with the valve.

Fault codes for Cointra that this part resolves.

CodeFaultDiagnosis and solution
E09High pressure alarmAn alarm has been triggered due to high pressure in the system. This can be dangerous and requires immediate attention. Check the valves and the condition of the system to determine if the safety valve is failing.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Cointra safety valve 9158449

Catalogue reference
9158449
Brand
Cointra
Type of part
Safety valves
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Setpoint
3 bar
Code engraved on the part
9158449
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the safety valve 9158449

Is this valve suitable for a Cointra SP 24 I?
Yes, it is listed as compatible with SP 24 I, as well as ED 21, SP 21, SP 27, SPA 27, SPI 21, and Supra Compact 21.
What pressure is the valve of the Cointra SPA 27 EI set to?
A 3 bar, read on the dial of the red cover.
Does reference 9158449 match the code engraved on the part?
Yes, the same code is engraved on the body and matches the catalog.
When should this valve be replaced in a Cointra Supra Compact 21 EI?
When it drips continuously or loses calibration.