Safety Valve 3 Bar Caleffi PN10 - Ref. 00200786
The safety valve releases water when the circuit pressure exceeds 3 bar, preventing damage to the boiler. If the safety valve fails, you will notice continuous dripping or that it does not discharge when it should. It is compatible with several boilers, including the ThemaClassic F24E, Themafast F30E, and Isomax F35E models, among others. You should replace it when it shows signs of leakage or does not function properly.
VAT included
Consult via WhatsAppSaunier Duval boilers compatible with reference 00200786
Safety valve with reference 00200786. 22 verified compatibilities: ThemaClassic F24E and ThemaClassic F25E.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Saunier Duval ThemaClassic F24E | ThemaClassic | Contrasted |
| Saunier Duval ThemaClassic F25E | ThemaClassic | Contrasted |
| Saunier Duval ThemaClassic C24E | ThemaClassic | Contrasted |
| Saunier Duval ThemaClassic C25E | ThemaClassic | Contrasted |
| Saunier Duval Themafast F24E | Themafast | Contrasted |
| Saunier Duval Themafast F25E | Themafast | Contrasted |
| Saunier Duval Themafast F28E | Themafast | Contrasted |
| Saunier Duval Themafast F30E | Themafast | Contrasted |
| Saunier Duval Themafast C24E | Themafast | Contrasted |
| Saunier Duval Themafast C25E | Themafast | Contrasted |
| Saunier Duval Thematek F24E | Thematek | Contrasted |
| Saunier Duval Thematek F25E | Thematek | Contrasted |
| Saunier Duval Thematek C24E | Thematek | Contrasted |
| Saunier Duval Thematek C25E | Thematek | Contrasted |
| Saunier Duval Thema NOx F25 | NOx Thema | Contrasted |
| Saunier Duval Isofast F35E | Isofast | Contrasted |
| Saunier Duval Isofast C35 E-A | Isofast | Contrasted |
| Saunier Duval Isofast F30E | Isofast | Contrasted |
| Saunier Duval Isomax F35E | Isomax | Contrasted |
| Saunier Duval Isomax C30 | Isomax | Contrasted |
| Saunier Duval Isotwin F30 | Isotwin | Contrasted |
| Saunier Duval Isotwin C30 | Isotwin | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if the reference 00200786 is the part for your boiler.
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 00200786. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the safety valve 00200786 resolves.
The safety valve releases pressure when the circuit exceeds its setting. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
Continuous dripping from the valve drain for no apparent reason.
Cause: The seat does not seal properly due to wear or limescale buildup.
Check the pre-charge pressure of the expansion vessel when cold: if it is low, the circuit rises faster and may cause dripping even if the valve is not broken.
- 02
Bleed water without the boiler forcing pressure.
Cause: An internal leak allows water to pass even below the setting of 3 bar.
Check the actual pressure of the circuit in cold and hot conditions with the manometer before replacing the gas valve.
- 03
Pressure loss in the circuit that requires frequent refilling.
Cause: If the seat does not close completely, the circuit loses water gradually without an obvious drip.
Note how many days it takes for the pressure to drop after refilling and rule out leaks in radiators or bleed valves before concluding that it is the gas valve.
- 04
It does not reset properly after bleeding: it continues to drip after activating the lever.
Cause: The manual firing can leave a limescale particle on the seat that prevents a tight seal.
Bleed two or three more times in a row to try to remove the dirt before considering the gas valve faulty.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Saunier Duval safety valve 00200786
- Catalogue reference
- 00200786
- Brand
- Saunier Duval
- Type of part
- Safety valves
- Units in stock
- 5 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Component manufacturer
- Caleffi
- fool
- 3 bar
- Maximum temperature
- 110°C
- Nominal pressure PN
- PN10
- Without contrast in independent external sources (0 sources).
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Saunier Duval Thematek F24E Manual (PDF)Document © Saunier Duval, provided as a technical reference.