Watts Safety Valve Biasi Myto Condens 24
The Watts Baxi Roca Myto Condens 24 safety valve is a crucial component in your boiler. Its function is to release water when the circuit pressure exceeds the limit, usually 3 bar, thus preventing damage to the system. If you notice that the valve is continuously dripping or not discharging when it should, it is a sign that it is failing. This valve is compatible with models such as Myto Condens Inox 24, Myto Condens Inox 35, Midas 24E, Midas Eco 24E, Midas Eco 28E, and Bianca 24E, among others. It should be replaced when it shows leaks or malfunction.
VAT included
Consult via WhatsAppBoilers Biasi compatible with reference BI1441101
Safety valve with reference BI1441101. Six confirmed compatibilities: Myto Condens Inox 24 and Myto Condens Inox 35.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Biasi Myto Condens Inox 24 | Biasi Myto Condens Inox | Contrasted |
| Biasi Myto Condens Inox 35 | Biasi Myto Condens Inox | Contrasted |
| Biasi Midas 24E | Biasi Midas / Midas Eco | Contrasted |
| Biasi Midas Eco 24E | Biasi Midas / Midas Eco | Contrasted |
| Biasi Midas Eco 28E | Biasi Midas / Midas Eco | Contrasted |
| Biasi Bianca 24E | Biasi Bianca | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if the part number BI1441101 is the one for your boiler.
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference BI1441101. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the safety valve BI1441101 resolves.
The safety valve releases pressure when the circuit exceeds its setting. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
Water is continuously leaking from the discharge hose.
Cause: The valve seat does not close properly and allows water to pass even when the circuit is under normal pressure.
Check if the expansion vessel has the correct air pressure when cold; a discharged vessel can cause the circuit pressure to rise and lead to dripping.
- 02
The circuit is losing pressure gradually, day by day.
Cause: An internal leak in the valve allows water to escape in small amounts without any noticeable dripping.
Check for moisture or scale buildup under the gas valve or in the drain before declaring it faulty, and also rule out leaks at other points in the circuit.
- 03
After operating the bleed lever, the valve continues to drip and does not close properly.
Cause: The manual firing can leave a particle on the seat that prevents complete closure.
Bleed two or three times in a row; if the seat only had loose scale, it can seal again.
- 04
The circuit needs to be filled more frequently than usual.
Cause: If the valve does not close completely after each small excess of pressure, it gradually empties the circuit.
Note how long it takes for the pressure to drop after refilling; if it’s days instead of weeks, it’s more likely to be the gas valve and not a leak in a radiator.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the safety valve Biasi BI1441101
- Catalogue reference
- BI1441101
- Brand
- Biasi
- Type of part
- Safety valves
- Units in stock
- 5 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Component manufacturer
- Watts
- The part has a raised symbol (a five-pointed star with a circle at each vertex) without any associated text; it appears to be a mold mark and does not provide a useful code for identifying the model.
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Biasi Myto Condens Inox 24 Manual (PDF)Document © Biasi, provided as a technical reference.