Safety Valve Ceraclass Excellence ZWC 35-3 MFA Ref. 8716010876
RefurbishedJunkersSafety valves

Safety Valve Ceraclass Excellence ZWC 35-3 MFA Ref. 8716010876

Stock · 5 units

The safety valve releases water if the pressure in the circuit of the Ceraclass Excellence ZWC 35-3 MFA boiler exceeds the usual limit of 3 bar. When it fails, it may drip continuously or not discharge when it should, which can cause problems in the system. This valve is compatible with other models in the Ceraclass Excellence range, such as the ZWC 35/35-3 MFA, ZWC 24/28-3 MFA, ZWC 28/28-3 MFA, and ZWC 30/30-3 MFA, among others. It should be replaced upon detecting these symptoms or if the fault code F9: Fault in the safety system appears.

VAT included

Compatibility

Junkers boilers compatible with reference 8716010876

Safety valve with reference 8716010876. Four confirmed compatibilities: ZWC 35/35-3 MFA and ZWC 24/28-3 MFA.

Proven compatibility

Boiler modelFamilyVerification
Junkers ZWC 35/35-3 MFACeraclass Excellence (ZWC)Contrasted
Junkers ZWC 24/28-3 MFACeraclass Excellence (ZWC)Contrasted
Junkers ZWC 28/28-3 MFACeraclass Excellence (ZWC)Contrasted
Junkers ZWC 30/30-3 MFACeraclass Excellence (ZWC)Contrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if the ref. 8716010876 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 8716010876. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the safety valve 8716010876 resolves.

The safety valve releases pressure when the circuit exceeds its setting. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The valve is continuously leaking from the discharge pipe, whether the boiler is stopped or running.

    Cause: The internal seat does not seal properly, usually due to limescale or wear, and allows water to pass through at normal pressure.

    Check the manometer to see that the cold pressure is normal: if it drips at normal pressure, the fault is in the seat.

  • 02

    The manometer shows a very high pressure and the gas valve does not activate to relieve it.

    Cause: The mechanism gets stuck due to lack of use, something common in valves that have never had to operate.

    Try the manual bleed, if it has one, a couple of times before replacing it: sometimes it's enough to clear the seat.

  • 03

    The pressure in the system gradually increases without anyone having refilled the circuit.

    Cause: If the valve does not bleed that excess in time, the pressure remains accumulated instead of being released in a controlled manner.

    First, rule out that the filling key is properly closed and not leaking before holding the safety valve responsible.

  • 04

    The puddle under the boiler appears and disappears depending on the days.

    Cause: It is typical of a seat that does not close completely: it drips more when the circuit pressure increases and less when it decreases.

    Compare the pressure on the manometer on the days it drips and on the days it doesn't to confirm that the pattern matches the valve.

Fault codes from Junkers that this part resolves.

CodeFaultDiagnosis and solution
F9Fault in the security systemThe boiler stops because the safety system has detected a problem. This may be due to a malfunction of the safety valve. It is advisable to check this valve to ensure it is functioning properly.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Junkers 8716010876 safety valve.

Catalogue reference
8716010876
Brand
Junkers
Type of part
Safety valves
Units in stock
5 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the safety valve 8716010876

Is the safety valve Ceraclass Excellence ZWC 35-3 MFA Ref. 8716010876 compatible with other models in the Ceraclass Excellence range?
Yes, it is compatible with the models ZWC 35/35-3 MFA, ZWC 24/28-3 MFA, ZWC 28/28-3 MFA, and ZWC 30/30-3 MFA.
What fault codes are documented for this gas valve?
The documented fault code for this gas valve is F9.
What is the reference for the safety valve Ceraclass Excellence ZWC 35-3 MFA?
The reference of the gas valve is VSCEZWC3535.
What should I do if my boiler shows fault code F9?
The fault code F9 may indicate a problem related to the safety valve. It is recommended to check the safety valve Ceraclass Excellence ZWC 35-3 MFA Ref. 8716010876.
Where can I find more information about the safety valve Ceraclass Excellence ZWC 35-3 MFA?
You can check the product's technical data sheet on our online store for more details about its installation and compatibility.

Spare parts related to Junkers Ceraclass Excellence (ZWC)

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Safety Valve Ceraclass Excellence ZWC 35-3 MFA Ref. 8716010876