Anstoss ZAG 2V Ignition Transformer for Chaffoteaux Ref. 07000065
RefurbishedChaffoteauxTransformersAnstoss Control Devices GmbH

Anstoss ZAG 2V Ignition Transformer for Chaffoteaux Ref. 07000065

Stock · 5 units

Ignition transformer for Chaffoteaux gas boilers, with code ZAG 2V (Best-Nr. 07000065) printed on the label. It generates the high voltage that produces the spark at the burner's ignition electrode. It is replaced when the boiler does not ignite or the electrode does not generate a spark with the rest of the circuit functioning correctly. Compatible with Luna Duo Tec MP, Luna HT, Luna3 System HT, Nuvola HT, and Power HT.

VAT included

Compatibility

Chaffoteaux boilers compatible with reference 07000066

Ignition transformer with reference 07000066. Two confirmed compatibilities: Siam 2-23 E CF and Siam 2-23 E FF.

Proven compatibility

Boiler modelFamilyVerification
Chaffoteaux Siam 2-23 E CFChaffoteauxContrasted
Chaffoteaux Siam 2-23 E FFChaffoteauxContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 07000066 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 07000066. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the ignition transformer 07000066 resolves.

The ignition transformer generates the high voltage for the spark of the electrodes. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not ignite on the first attempt; it makes several attempts before starting or locking out.

    Cause: The transformer does not receive enough current in the first cycle and the unit retries before locking.

    Check the fault code on the display: if it indicates a ignition failure on the first attempts, the transformer is the first suspect.

  • 02

    The buzzing of the ignition attempt can be heard, but no spark is visible at the electrode.

    Cause: The transformer tries to generate high voltage, but it does not reach the electrode cleanly, usually due to the high voltage cable.

    Check the high voltage cable and its connection to the transformer and the electrode before replacing the part.

  • 03

    The spark jumps irregularly, sometimes at the tip of the electrode and other times it seems to disappear.

    Cause: The electrode has cracked porcelain or a worn tip and diverts part of the current.

    Check the ignition electrode, its porcelain, and the gap between the tips before declaring the transformer faulty.

  • 04

    The boiler locks on the display with a fault code for ignition after several attempts.

    Cause: The ground connection of the burner is loose or poorly connected, weakening the spark until the control board locks out for safety.

    Check that the cable or the grounding strip of the burner is properly connected before replacing the transformer.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Chaffoteaux Ignition Transformer Datasheet 07000066

Catalogue reference
07000066
Brand
Chaffoteaux
Type of part
Transformers
Units in stock
5 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Model
ZAG 2V
Code (Best-Nr.)
07000065
Voltage
220-240 V
Frequency
50-60 Hz
Power (Pzu)
3 VA
Maximum temperature
+85°C
Standard
DIN DVGW 93.02f142
Wiring
PE N L
Before purchasing
  • 07000066 is another item from the same ZAG 2V family (variant S3) and is NOT equivalent to this part (variant S2, 07000065); do not confuse them.
Frequently Asked Questions

Frequently asked questions about the ignition transformer 07000066

Is the Anstoss ZAG 2V ignition transformer with reference 07000065 compatible with other Chaffoteaux boiler models?
This transformer is compatible only with the Siam 2-23 E CF and Siam 2-23 E FF models.
What fault can the ZAG 2V transformer solve in compatible models?
It is replaced when the boiler does not ignite because the electrode does not generate a spark, as long as the rest of the ignition circuit is correct.
What is the supply voltage of the ZAG 2V transformer?
It operates at 220-240V and 50-60Hz, according to the product label.
What is the reference for the ZAG 2V transformer that should be looked for when purchasing?
The reference you need to look for is TE23ECF, which corresponds to the ignition transformer Anstoss ZAG 2V.
What does the code Best-Nr. 07000065 on the transformer label mean?
It is the manufacturer's reference code that identifies this unit as 07000065.
Are there documented fault codes for this transformer?
No, there are no documented fault codes for this product.

Spare parts related to Chaffoteaux Chaffoteaux

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Anstoss ZAG 2V Ignition Transformer for Chaffoteaux Ref. 07000065