Honeywell Ignition Transformer AC1A114 - Hermann Micra Condens 26 / Master / Spazio / Thesi 26-32 / Saunier Duval Acquaplus 32

Honeywell Ignition Transformer AC1A114 - Hermann Micra Condens 26 / Master / Spazio / Thesi 26-32 / Saunier Duval Acquaplus 32

Stock · 5 units

Honeywell ignition transformer, reference AC1A114, identified by the printed marking on the part. It operates at 50-60 Hz. It is installed in Hermann Micra Condens, Master, Spazio, and Thesi 26/32 boilers, as well as in the Saunier Duval Acquaplus Condensing 32. It is replaced when the burner ignition fails due to the absence of a spark. The store catalog listed a different reference (H052005087) that does not correspond to this part.

VAT included

Compatibility

Renova boilers compatible with reference H052005087

Ignition transformer with reference H052005087. A proven compatibility: Micra Condens 26.

Proven compatibility

Boiler modelFamilyVerification
Renova Micra Condens 26Micra CondensContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. H052005087 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference H052005087. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the ignition transformer H052005087 resolves.

The ignition transformer generates the high voltage for the spark of the electrodes. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not ignite the burner even though gas is arriving normally.

    Cause: The transformer has an open internal coil and does not generate the spark needed for the electrode.

    With the boiler in ignition cycle, check if there is a visible spark at the electrode before replacing the transformer.

  • 02

    The spark appears intermittently, sometimes yes and sometimes no, without a clear pattern.

    Cause: The connectors of the transformer or the electrode are oxidized and reduce the current reaching it without the part being broken.

    Check that the connectors of the transformer and the high voltage cable are not oxidized or loose.

  • 03

    The ignition fault appears after a period of humidity or after cleaning the combustion chamber.

    Cause: The condensation inherent to these boilers promotes that the high voltage is grounded before reaching the electrode.

    Check the combustion chamber and the area around the electrode for moisture or accumulated condensation before replacing the transformer.

  • 04

    There is a spark at the electrode, but the burner does not ignite.

    Cause: If there is a spark present, the transformer is likely functioning: the problem is in another part of the ignition circuit.

    If you confirm a visible and constant spark, check the gas supply and the gas valve before replacing the transformer.

Fault codes for Renova that this spare part resolves.

CodeFaultDiagnosis and solution
01Ignition fault: the burner does not ignite normally or the flame does not form/extinguishes unexpectedly (steady red LED, lockout after several attempts).The ignition transformer generates the spark that ignites the burner; if it is faulty, no spark occurs and the boiler locks with Error 01. Check: with the boiler in demand, verify if there is a spark at the electrode and measure the high voltage output of the transformer; rule out the electrode, cable, connector, and gas supply first, as this same code can be caused by other components of the ignition group.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Renova H052005087 ignition transformer datasheet

Catalogue reference
H052005087
Brand
Renova
Type of part
Transformers
Units in stock
5 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Type
AC1A114
Frequency
50-60 Hz
Manufacturing date
89/18 (uninterpreted format)
Frequently Asked Questions

Frequently asked questions about the ignition transformer H052005087

What is the correct reference for the transformer of the Hermann Micra Condens 26, AC1A114 or H052005087?
AC1A114, engraved on the part itself; the old catalog showed H052005087, which does not correspond to this unit.
Is the AC1A114 transformer an original part from Hermann?
No, it is manufactured by Honeywell and is used as a spare part in several Hermann boilers and in the Saunier Duval Acquaplus Condensing 32.
Is this Honeywell AC1A114 transformer suitable for the Hermann Micra Condens 26?
Yes, it is one of the compatible models according to the list for this part.
Does this transformer AC1A114 also work for the Saunier Duval Acquaplus Condensing 32?
Yes, the Acquaplus Condensing 32 is on the list of compatible boilers for this part.
When should the AC1A114 transformer be replaced in a Hermann Spazio Condensing 26?
When the burner ignition fails due to lack of spark.

Spare parts related to Renova Micra Condens

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Honeywell Ignition Transformer AC1A114 - Hermann Micra Condens 26 / Master / Spazio / Thesi 26-32 / Saunier Duval Acquaplus 32