Hermann Micra 2 Ignition Transformer - Honeywell AC1A114 - Ref. 52004120

Hermann Micra 2 Ignition Transformer - Honeywell AC1A114 - Ref. 52004120

Stock · 5 units

Ignition transformer for Hermann boilers. It generates the high voltage necessary to produce the spark that ignites the burner. According to the label, it operates at 230V, 50-60Hz, with a working temperature range of -20 to 90 degrees C. It is replaced when the boiler fails to ignite due to lack of spark or an ignition fault occurs.

VAT included

Compatibility

Hermann boilers compatible with reference 52004120

Ignition transformer with reference 52004120. Seven verified compatibilities: 2 and Master.

Proven compatibility

Boiler modelFamilyVerification
Hermann 2HabitatContrasted
Hermann MasterMasterContrasted
Hermann 2MicraContrasted
Hermann OberonOberonContrasted
Hermann ThesiThesisContrasted
Hermann AtlasTiberisContrasted
Hermann TritonTritonContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 52004120 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 52004120. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the ignition transformer 52004120 resolves.

The ignition transformer generates the high voltage for the spark of the electrodes. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not ignite and there is no spark at the electrode, although the fan and gas are functioning normally.

    Cause: The transformer does not deliver the high voltage needed by the electrode to produce the spark.

    With the fan and gas operating, check the electrode and its cable.

  • 02

    There is a fault or ignition lockout while everything else is in order.

    Cause: If a flame is not detected within the safety time, the control unit cuts off the gas and displays the warning.

    Check the electrode tip spacing and ensure there is no soot; if it is fine, then suspect the transformer.

  • 03

    The spark is intermittent or weak at the electrode.

    Cause: A damaged winding in the transformer causes irregular discharges instead of a steady spark.

    Check the ground connection of the burner before replacing the coil: a poor ground can cause the same effect.

  • 04

    The ignition fault mainly occurs during cold starts, early in the morning.

    Cause: The condensation humidity accumulated overnight can cause the transformer to lose voltage or divert the spark to ground.

    If the fault occurs more frequently during the first start of the day, check for visible moisture in the area of the transformer and the electrode.

Fault codes Hermann that this part solves

CodeFaultDiagnosis and solution
01Ignition fault / incorrect combustion.Defective ignition transformer (accenditore): it does not supply high voltage to the electrodes, there is no spark, and the electronics do not detect a flame, resulting in a lockout with 01. Check for the presence of a spark at startup, power supply to the accenditore, and continuity of the HT cable/electrode.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Hermann 52004120 ignition transformer datasheet

Catalogue reference
52004120
Brand
Hermann
Type of part
Transformers
Units in stock
5 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Manufacturer
Honeywell
Model
AC1A114
Voltage
230V
Frequency
50-60Hz
Temperature range
-20/90°C
Before purchasing
  • The manufacturer of the transformer is Honeywell; Hermann is the manufacturer of the boiler, not the component.
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the ignition transformer 52004120

Who manufactures the ignition transformer for the Hermann Micra 2 boiler?
Honeywell, according to the printing on the part.
What voltage does the Honeywell AC1A114 transformer of the Hermann Micra 2 operate at?
A 230V, 50-60Hz, according to the label.
What is the operating temperature range of the transformer Ref. 52004120?
From -20 to 90 degrees C, according to the label.
In which Hermann boilers other than the Micra 2 is this transformer installed?
It is also installed in the Hermann Habitat 2, Master, Oberon, Thesi, Tiberis Atlas, and Triton boilers.
What fault indicates that the ignition transformer of the Hermann Thesi needs to be replaced?
It is replaced when the boiler does not ignite due to lack of spark or a fault code for ignition appears.