Ignition Transformer ERA BV 0660 86 Junkers ZWE24-2KP and Compatible Ref. 8747201176
RefurbishedJunkersTransformersERA

Ignition Transformer ERA BV 0660 86 Junkers ZWE24-2KP and Compatible Ref. 8747201176

Stock · 5 units

Ignition transformer manufactured by ERA (code BV 0660 86), installed in Junkers boilers of the ZE24 and ZWE24-2K series. It operates with a primary of 220 V-50/60 Hz and a secondary of 31 V-28 VA; it withstands up to 40°C ambient and 125°C in the winding. It is replaced when the boiler ignition fails and the component is ruled out as the cause.

VAT included

Compatibility

Junkers boilers compatible with reference 87472011760

Ignition transformer with reference 87472011760. Three confirmed compatibilities: Eurostar ZWE 24-2 KDP and Eurostar ZWE 24-2 KP.

Proven compatibility

Boiler modelFamilyVerification
Junkers Eurostar ZWE 24-2 KDPJunkersContrasted
Junkers Eurostar ZWE 24-2 KPJunkersContrasted
Junkers Novatherm ZWE 24-2 KDGJunkersContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 87472011760 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 87472011760. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the ignition transformer 87472011760 resolves.

The ignition transformer generates the high voltage for the spark of the electrodes. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not ignite and no spark is visible at the electrode.

    Cause: The transformer does not deliver the high voltage needed by the electrode to generate the spark.

    Before changing it, check that 230V is reaching the boiler and that the fuse is not blown; without input power, it won't spark even if it's functioning properly.

  • 02

    The boiler is locking out with an ignition fault code.

    Cause: No flame detected at startup, the control board interrupts the gas supply for safety.

    Check the condition of the electrode and its cable before replacing the transformer: a crack in the ceramic causes the same blockage.

  • 03

    The spark sounds weak or intermittent when starting the boiler.

    Cause: A partially damaged winding in the transformer produces an irregular discharge instead of a firm and continuous spark.

    Check the gap between the electrode tips; if it is not correct, fix that first because it mimics the same fault.

  • 04

    The ignition fault comes and goes; it doesn't happen every time during the same start-up.

    Cause: A transformer that starts to fail due to overheating can produce a good spark when cold and fail after a while of operation.

    Note if the fault occurs more often with the boiler already hot from previous starts; this helps to differentiate it from a dirty electrode.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Junkers ignition transformer 87472011760

Catalogue reference
87472011760
Brand
Junkers
Type of part
Transformers
Units in stock
5 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Component manufacturer
ERA
Component code
BV 0660 86
Primary (pins 5-7)
220 V, 50/60 Hz
Secondary (pins 1-2)
31 V, 28 VA
Ambient temperature (ta)
40°C/E
Winding temperature (TS)
125°C
Bosch/Junkers code printed on label
8747201176
Frequently Asked Questions

Frequently asked questions about the ignition transformer 87472011760

Is the ignition transformer ERA BV 0660 86 original from Junkers for the ZWE24-2KP?
The manufacturer listed on the label is ERA, not Junkers. Bosch/Junkers markets it under its own reference.
Is this transformer ERA BV 0660 86 compatible with the boiler Eurostar ZWE 24-2 KDP?
Yes, the Eurostar ZWE 24-2 KDP is on the list of compatible boilers, along with the Eurostar ZWE 24-2 KP and the Novatherm ZWE 24-2 KDG.
What voltage does the transformer ERA BV 0660 86 of the Junkers ZWE24-2KP operate at?
The transformer operates at a primary voltage of 220 V-50/60 Hz and a secondary of 31 V-28 VA, withstanding up to 40 °C ambient and 125 °C in the winding.
When is it necessary to change the ERA transformer of the Junkers ZWE24-2KP?
It is advisable to replace it when the boiler does not ignite or the burner spark fails, as long as the transformer has been ruled out as the cause.
How many models are compatible with the transformer ERA BV 0660 86?
This transformer is compatible with a total of 3 models: Eurostar ZWE 24-2 KDP, Eurostar ZWE 24-2 KP, and Novatherm ZWE 24-2 KDG.
What is the reference for the ignition transformer for the Junkers ZWE24-2KP?
The reference for the ignition transformer is TCJZWE24.

Spare parts related to Junkers Junkers

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Ignition Transformer ERA BV 0660 86 Junkers ZWE24-2KP and Compatible Ref. 8747201176