Ignition Transformer ERA BV 0660 86 Junkers ZWE24-2KP and Compatible Ref. 8747201176
Ignition transformer manufactured by ERA (code BV 0660 86), installed in Junkers boilers of the ZE24 and ZWE24-2K series. It operates with a primary of 220 V-50/60 Hz and a secondary of 31 V-28 VA; it withstands up to 40°C ambient and 125°C in the winding. It is replaced when the boiler ignition fails and the component is ruled out as the cause.
VAT included
Consult via WhatsAppJunkers boilers compatible with reference 87472011760
Ignition transformer with reference 87472011760. Three confirmed compatibilities: Eurostar ZWE 24-2 KDP and Eurostar ZWE 24-2 KP.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Junkers Eurostar ZWE 24-2 KDP | Junkers | Contrasted |
| Junkers Eurostar ZWE 24-2 KP | Junkers | Contrasted |
| Junkers Novatherm ZWE 24-2 KDG | Junkers | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. 87472011760 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 87472011760. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the ignition transformer 87472011760 resolves.
The ignition transformer generates the high voltage for the spark of the electrodes. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler does not ignite and no spark is visible at the electrode.
Cause: The transformer does not deliver the high voltage needed by the electrode to generate the spark.
Before changing it, check that 230V is reaching the boiler and that the fuse is not blown; without input power, it won't spark even if it's functioning properly.
- 02
The boiler is locking out with an ignition fault code.
Cause: No flame detected at startup, the control board interrupts the gas supply for safety.
Check the condition of the electrode and its cable before replacing the transformer: a crack in the ceramic causes the same blockage.
- 03
The spark sounds weak or intermittent when starting the boiler.
Cause: A partially damaged winding in the transformer produces an irregular discharge instead of a firm and continuous spark.
Check the gap between the electrode tips; if it is not correct, fix that first because it mimics the same fault.
- 04
The ignition fault comes and goes; it doesn't happen every time during the same start-up.
Cause: A transformer that starts to fail due to overheating can produce a good spark when cold and fail after a while of operation.
Note if the fault occurs more often with the boiler already hot from previous starts; this helps to differentiate it from a dirty electrode.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Junkers ignition transformer 87472011760
- Catalogue reference
- 87472011760
- Brand
- Junkers
- Type of part
- Transformers
- Units in stock
- 5 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Component manufacturer
- ERA
- Component code
- BV 0660 86
- Primary (pins 5-7)
- 220 V, 50/60 Hz
- Secondary (pins 1-2)
- 31 V, 28 VA
- Ambient temperature (ta)
- 40°C/E
- Winding temperature (TS)
- 125°C
- Bosch/Junkers code printed on label
- 8747201176