Ignition Transformer Era - Junkers ZW20-1 AME KE - Ref. 87472012720
RefurbishedJunkersTransformersERA

Ignition Transformer Era - Junkers ZW20-1 AME KE - Ref. 87472012720

Stock · 5 units

In Junkers boilers, the Ignition Transformer - Junkers ZW20-1 AME KE - Ref. 87472012720 generates the spark needed to ignite the burner. If this part fails, you will notice that the boiler will attempt to start without achieving a flame, which will cause the reset button to blink at 1 Hz, indicating an ignition fault. It is compatible with models such as Novastar ZW20-1 AME, Novastar ZW20-1 KE, Novatherm ZW20-1 AME, among others. It is recommended to replace it when you observe these failure symptoms.

VAT included

Compatibility

Junkers boilers compatible with reference 87472012720

Ignition transformer with reference 87472012720. Seven verified compatibilities: Novastar ZW20-1 AME and Novastar ZW20-1 KE.

Proven compatibility

Boiler modelFamilyVerification
Junkers Novastar ZW20-1 AMEJunkersContrasted
Junkers Novastar ZW20-1 KEJunkersContrasted
Junkers Novatherm ZW20-1 AMEJunkersContrasted
Junkers Novatherm ZW20-1 KEJunkersContrasted
Junkers Novatherm ZW20-1 KDJunkersContrasted
Junkers Novastar ZW20 AMEJunkersContrasted
Junkers Novastar ZW20 KEJunkersContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 87472012720 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 87472012720. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the ignition transformer 87472012720 resolves.

The ignition transformer generates the high voltage for the spark of the electrodes. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler tries to ignite several times in a row but fails to produce a flame.

    Cause: The transformer does not generate the spark necessary to ignite the gas, so the boiler repeats the attempt.

    Look through the peephole to see if there is a visible spark at the electrode during the attempt; if there isn't, check the ignition wiring.

  • 02

    A weak or almost inaudible spark can be heard when starting.

    Cause: The transformer is damaged and does not provide enough power, which causes a weak spark.

    Check that the electrode is not covered in soot and that the tip is not worn, as this can also dampen the spark.

  • 03

    The boiler locks out due to ignition failure after attempts.

    Cause: The control unit cuts off the gas because it does not detect a flame within the established time, for safety reasons.

    Check the ground connection of the burner; a loose ground can cause the same lockout as a faulty coil.

  • 04

    The fault occurs more with the cold boiler than with the hot boiler, or vice versa.

    Cause: Humidity in the transformer affects more in cold conditions, causing spark leaks to ground.

    If the fault occurs more frequently during cold starts, check for condensation or damp dirt around the transformer before replacing it.

Fault codes from Junkers that this part resolves.

CodeFaultDiagnosis and solution
The reset button flashes at 1 Hz (once per second)Ignition fault.Ignition transformer fault: it does not supply high voltage to the spark plugs and there is no spark; the control exhausts the safety time without flame and locks out. Verification: check for spark at the electrodes; measure continuity/insulation of the transformer and check fuse/power supply according to the electrical test in the manual.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Junkers 87472012720 ignition transformer datasheet

Catalogue reference
87472012720
Brand
Junkers
Type of part
Transformers
Units in stock
5 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Actual manufacturer
was
Core type
Typ EI 60/30.5 (equivalent was BV 060-0285.0)
Before purchasing
  • The actual manufacturer of the transformer is era; Junkers/Bosch is the brand of the boiler that assigns the commercial reference 87472012720, not the manufacturer of the component.
Frequently Asked Questions

Frequently asked questions about the ignition transformer 87472012720

Who actually manufactures the transformer of the Junkers ZW20-1 AME KE?
It was about the photos; Junkers/Bosch only assigns the commercial reference 87472012720 to the part.
Does this transformer also work for a Junkers ZW20-2 KE23 S2895?
Yes, the ZW20-2KE23S2895 is on the list of compatible boilers for this part.
Why is the reference 87472012720 from Junkers if the transformer is manufactured by Era?
Junkers/Bosch assigns its own commercial reference to a component manufactured by Era.

Spare parts related to Junkers Junkers

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Ignition Transformer Era - Junkers ZW20-1 AME KE - Ref. 87472012720