Ineco Ignition Transformer Fagor FEE20E/EIN Type 697250 64
Ignition transformer for Fagor boiler FEE20E/EIN. Manufactured by Ineco, in Oggiono (Italy), as stated on the piece's own marking: Type 697250 64, 220-240 V at 50-60 Hz, 0.7 VA, thermal class T80°. It is part of the ignition circuit; it is replaced when the system does not ignite and the electrode or the control unit has been ruled out.
VAT included
Consult via WhatsAppFagor boilers compatible with reference MU0813800
Ignition transformer with reference MU0813800. A proven compatibility: FEE20E/EIN.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Fagor FEE20E/EIN | FEE20E/EIN | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. MU0813800 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference MU0813800. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the ignition transformer MU0813800 resolves.
The ignition transformer generates the high voltage for the spark of the electrodes. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler does not ignite the burner on any attempt.
Cause: The transformer does not deliver the necessary voltage to produce the spark at the electrode.
Check the high voltage cable and the electrode before ruling out the transformer, a damaged cable causes the same fault.
- 02
The ignition spark is neither visible nor audible at the electrode.
Cause: Internal winding damaged or internal fuse blown that cuts the output current of the transformer.
With a multimeter, check for continuity in the primary of the transformer before replacing it.
- 03
The boiler locks out right after the start-up attempt due to ignition failure.
Cause: Without a spark, the PCB does not detect a flame through ionization and locks the system for safety.
First, rule out the ignition electrode and its cable, as a fault there causes the same lockout.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Fagor MU0813800 ignition transformer datasheet
- Catalogue reference
- MU0813800
- Brand
- Fagor
- Type of part
- Transformers
- Units in stock
- 5 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- manufacturer
- Ineco (Oggiono, Italy)
- type (code)
- 697250 64
- voltage
- 220-240 V, 50-60 Hz
- power
- 0.7 VA
- Temperature class
- T80°