Look for the warning of your Protherm.

Choose your model or search for the code on the screen. You will see what it indicates and to which family it belongs, without having to open the PDF.
Keep the letters and zeros. The same code can mean something different in another family. View models and guides · Download manuals
41 documented notices, grouped by family.
A warning does not confirm a faulty part by itself. Internal checks are the responsibility of a professional.
Protherm Puma Condens AS/2
18/24 MKV-AS/2 and 24/28 MKV-AS/2
Documented entries for this family. The coverage does not extend to other models or editions.
41 visible alerts
Code / warningF.00
Flow temperature sensor interruption
Protherm Puma Condens AS/2 18/24 MKV-AS/2 and 24/28 MKV-AS/2
Code / warningF.01
Return temperature sensor interruption
Protherm Puma Condens AS/2 18/24 MKV-AS/2 and 24/28 MKV-AS/2
Code / warningF.10
Short circuit of the supply temperature sensor.
Protherm Puma Condens AS/2 18/24 MKV-AS/2 and 24/28 MKV-AS/2
Code / warningF.11
Return temperature sensor short circuit
Protherm Puma Condens AS/2 18/24 MKV-AS/2 and 24/28 MKV-AS/2
Code / warningF.13
Short circuit in the accumulator temperature sensor.
Protherm Puma Condens AS/2 18/24 MKV-AS/2 and 24/28 MKV-AS/2
Code / warningF.20
Safety disconnection of the temperature limiter
Protherm Puma Condens AS/2 18/24 MKV-AS/2 and 24/28 MKV-AS/2
Code / warningF.22
Installation pressure too low
Protherm Puma Condens AS/2 18/24 MKV-AS/2 and 24/28 MKV-AS/2
Code / warningF.23
Safety shutdown: excessive temperature variation
Protherm Puma Condens AS/2 18/24 MKV-AS/2 and 24/28 MKV-AS/2
Code / warningF.24
Safety disconnection, temperature rise too fast
Protherm Puma Condens AS/2 18/24 MKV-AS/2 and 24/28 MKV-AS/2
Code / warningF.25
Safety disconnection: flue gas temperature very high
Protherm Puma Condens AS/2 18/24 MKV-AS/2 and 24/28 MKV-AS/2
Code / warningF.27
Safety disconnection, flame simulation
Protherm Puma Condens AS/2 18/24 MKV-AS/2 and 24/28 MKV-AS/2
Code / warningF.28
Failed ignition
Protherm Puma Condens AS/2 18/24 MKV-AS/2 and 24/28 MKV-AS/2
Code / warningF.29
Ignition and control error during operation, the flame is off.
Protherm Puma Condens AS/2 18/24 MKV-AS/2 and 24/28 MKV-AS/2
Code / warningF.32
Fault: fan
Protherm Puma Condens AS/2 18/24 MKV-AS/2 and 24/28 MKV-AS/2
Code / warningF.33
Excessive pressure losses in the air intake/exhaust gas system
Protherm Puma Condens AS/2 18/24 MKV-AS/2 and 24/28 MKV-AS/2
Code / warningF.46
Short circuit of the cold water sensor
Protherm Puma Condens AS/2 18/24 MKV-AS/2 and 24/28 MKV-AS/2
Code / warningF.49
Fault: eBUS
Protherm Puma Condens AS/2 18/24 MKV-AS/2 and 24/28 MKV-AS/2
Code / warningF.61
Fuel control valve error
Protherm Puma Condens AS/2 18/24 MKV-AS/2 and 24/28 MKV-AS/2
Code / warningF.62
Error, delayed disconnection of the fuel control valve
Protherm Puma Condens AS/2 18/24 MKV-AS/2 and 24/28 MKV-AS/2
Code / warningF.63
Fault: EEPROM
Protherm Puma Condens AS/2 18/24 MKV-AS/2 and 24/28 MKV-AS/2
Code / warningF.64
Fault, electronics/temperature sensor
Protherm Puma Condens AS/2 18/24 MKV-AS/2 and 24/28 MKV-AS/2
Code / warningF.65
Electronic temperature fault
Protherm Puma Condens AS/2 18/24 MKV-AS/2 and 24/28 MKV-AS/2
Code / warningF.67
Fault: electronics/flame
Protherm Puma Condens AS/2 18/24 MKV-AS/2 and 24/28 MKV-AS/2
Code / warningF.68
Fault: unstable flame signal
Protherm Puma Condens AS/2 18/24 MKV-AS/2 and 24/28 MKV-AS/2
Code / warningF.70
Invalid device identification (DSN: "Device Specific Number")
Protherm Puma Condens AS/2 18/24 MKV-AS/2 and 24/28 MKV-AS/2
Code / warningF.71
Fault in the supply temperature sensor
Protherm Puma Condens AS/2 18/24 MKV-AS/2 and 24/28 MKV-AS/2
Code / warningF.72
Fault, return temperature sensor
Protherm Puma Condens AS/2 18/24 MKV-AS/2 and 24/28 MKV-AS/2
Code / warningF.73
Water pressure sensor signal out of range (too low)
Protherm Puma Condens AS/2 18/24 MKV-AS/2 and 24/28 MKV-AS/2
Code / warningF.74
Water pressure sensor signal out of range (too high)
Protherm Puma Condens AS/2 18/24 MKV-AS/2 and 24/28 MKV-AS/2
Code / warningF.75
Pump fault/water shortage
Protherm Puma Condens AS/2 18/24 MKV-AS/2 and 24/28 MKV-AS/2
Code / warningF.76
Fault, thermal device lock
Protherm Puma Condens AS/2 18/24 MKV-AS/2 and 24/28 MKV-AS/2
Code / warningF.77
Fault, anti-return flap for combustion gases/condensate pump
Protherm Puma Condens AS/2 18/24 MKV-AS/2 and 24/28 MKV-AS/2
Code / warningF.78
Interruption of the domestic hot water outlet temperature sensor with external control
Protherm Puma Condens AS/2 18/24 MKV-AS/2 and 24/28 MKV-AS/2
Code / warningF.83
NTC temperature fluctuation fault
Protherm Puma Condens AS/2 18/24 MKV-AS/2 and 24/28 MKV-AS/2
Code / warningF.84
The NTC temperature difference is unbelievable.
Protherm Puma Condens AS/2 18/24 MKV-AS/2 and 24/28 MKV-AS/2
Code / warningF.85
Incorrectly mounted (swapped) supply and return temperature sensors
Protherm Puma Condens AS/2 18/24 MKV-AS/2 and 24/28 MKV-AS/2
Code / warningF.86
External safety disconnection
Protherm Puma Condens AS/2 18/24 MKV-AS/2 and 24/28 MKV-AS/2
Code / warningF.87
Ignition electrode fault
Protherm Puma Condens AS/2 18/24 MKV-AS/2 and 24/28 MKV-AS/2
Code / warningF.88
Fault in the gas valve
Protherm Puma Condens AS/2 18/24 MKV-AS/2 and 24/28 MKV-AS/2
Code / warningF.89
Fault in the pump
Protherm Puma Condens AS/2 18/24 MKV-AS/2 and 24/28 MKV-AS/2
Code / warningF.97
Main PCB self-check fault
Protherm Puma Condens AS/2 18/24 MKV-AS/2 and 24/28 MKV-AS/2
We cannot find that warning for the selection. Check the model and the complete code. If it still does not appear, consult its manual or request a diagnosis; do not use that of another family.
What to do with this information?
Note the warning and the exact model. Please indicate the pressure displayed on the screen and whether the fault affects the domestic hot water, heating, or both services.
Check the external checks in the user instructions for your equipment. Do not open the casing or interfere with gas, electricity, or combustion. If the fault persists or reappears, request professional diagnosis before repeating resets or changing spare parts.
Protherm models and specific guides

Check the complete reference.
Identify whether your Puma Condens corresponds to 18/24 MKV-AS/2 or 24/28 MKV-AS/2. These variants share the indicated manual; they do not extrapolate to other generations.
The inquiry covers the indicated families and documents, not all the boilers manufactured by the brand.
- Protherm Puma Condens AS/218/24 MKV-AS/2 and 24/28 MKV-AS/241 notices on this pageModel-specific guide
Do you need help with your Protherm boiler? Consult the Protherm boiler repair in Madrid.
Protherm PDF manuals by model
Choose the document of your reference and edition. PDFs can be downloaded from Uniclima without leaving this page. The language alone does not certify the country of marketing.