3-Way Valve Actuator Motor Baxi Novanox 24 - Ref. 31650036.00
RefurbishedBaxi3-way valves

3-Way Valve Actuator Motor Baxi Novanox 24 - Ref. 31650036.00

Stock · 20 units

Three-way valve actuator motor that diverts the circuit between heating and domestic hot water in the boiler. Operates at 220V-240V, 50/60Hz, thermal class T70. It is replaced when the boiler does not switch between services, gets stuck in one position, or the motor does not respond. Compatible with boilers from the Altais, Bios, Deimos, Neodens, Novadens, Novamax, Novanox, Platinum, and Vega Plus ranges.

VAT included

Compatibility

Baxi boilers compatible with reference 125564734

3-way valve with reference 125564734. Nine confirmed compatibilities: NOVANOX 24/24F and NOVANOX 28/28F.

Proven compatibility

Boiler modelFamilyVerification
Baxi NOVANOX 24/24FNOVANOXContrasted
Baxi NOVANOX 28/28FNOVANOXContrasted
Baxi NEODENS 24/24FNEODENSContrasted
Baxi NEODENS 28/28FNEODENSContrasted
Baxi PLATINUM COMPACT 24/24FPLATINUMContrasted
Baxi PLATINUM 24 AFPLATINUMContrasted
Baxi PLATINUM 28 AFPLATINUMContrasted
Baxi ALTAIS 24/24ALTAISContrasted
Baxi ALTAIS 24/24FALTAISContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 125564734 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 125564734. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the 3-way valve 125564734 resolves.

The 3-way valve diverts water between heating and domestic hot water. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not switch between heating and domestic hot water when you open a tap.

    Cause: The actuator does not move the valve and it continues to distribute water to the circuit that it shouldn't.

    Check if the motor spins when requesting domestic hot water: if nothing moves, first check the power supply to the motor.

  • 02

    There is hot water at the tap but the radiators are not heating, or vice versa.

    Cause: The valve has become stuck in one of the two positions and does not switch to the other circuit.

    Note in which service the boiler remains fixed; if it is always the same, help to narrow it down to whether it is the motor or the gas valve.

  • 03

    There is moisture or dripping in the area where the 3-way valve is installed.

    Cause: A gasket or the body of the valve has lost tightness, which is different from a motor fault.

    Dry the area and check if the leak reappears with the boiler running before requesting the motor: it could just be a gasket.

  • 04

    The motor makes noise or struggles when trying to move the gas valve, but it does not turn.

    Cause: The motor is forcing against a jammed mechanism, usually due to limescale or dirt accumulated in the body of the gas valve.

    Try to move the mechanism by hand, if the model allows it, to distinguish a mechanical blockage from an electrical fault of the motor.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Baxi 125564734 three-way valve.

Catalogue reference
125564734
Brand
Baxi
Type of part
3-way valves
Units in stock
20 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Supply voltage
220V-240V
Frequency
50/60Hz
Thermal class
T70
Product code
31650036.00
Secondary code
7101883.01
Batch/date marking
0510
Before purchasing
  • The boiler brand (Baxi Roca) comes from the current catalog reference; the list of compatible models from the source material does not include the brand name next to each model.
Frequently Asked Questions

Frequently asked questions about the 3-way valve 125564734.

When should the actuator motor of the 3-way valve of the Baxi Roca Novanox 24 boiler be replaced?
When the boiler does not switch between heating and domestic hot water, it gets stuck in one position or the motor does not respond.
What voltage does the actuator motor of the Baxi Novanox 24 operate at?
A 220V-240V, 50/60 Hz, with thermal class T70, according to the part label.
Is this actuator motor compatible with other Baxi boilers?
This actuator motor is compatible with boilers from the NOVANOX, NEODENS, PLATINUM, and ALTAIS ranges, with a total of 9 confirmed models.
What is the reference for the actuator motor of the 3-way valve for the Baxi Novanox 24?
The reference for the actuator motor is MV3VNOVANOX24.
What symptoms indicate that the actuator motor of the 3-way valve needs to be replaced?
The symptoms include that the boiler does not switch between heating and domestic hot water or that the motor does not respond.
What are the ranges of boilers compatible with the actuator motor MV3VNOVANOX24?
The compatible ranges are NOVANOX, NEODENS, PLATINUM, and ALTAIS.