Expansion Vessel Sime Metropolis H25BF · 5183726
- Delivery to the EU in 2–6 working days · Depending on the country; cost shown at checkout
- Returns within 14 days, spare part not installed
- Inspected and tested, warranty 1 year
Is it compatible with your boiler?
Sime boilers compatible with reference 5183726
- Metropolis DGT 25 BFSime
- Metropolis DGT 25 OFSime
- Metropolis DGT 30 BFSime
- Metropolis Digito 25CSime
- Metropolis Digito 25VSime
- Metropolis Digito 30VSime
- Ecomfort Plus 25 HE-EVSime
- Ecomfort Plus 30 HE-EVSime
- Brava DGT-HE 12TSime
- Brava DGT-HE 25Sime
- Brava DGT-HE 30Sime
- Brava DGT-HE 35Sime
- Format DGT 25 BFSime
- Format GPL DGT 25 BFSime
- Format GPL DGT 30 BFSime
- Format MET DGT 25 BFSime
- Format MET DGT 30 BFSime
- Format Low Nox 25 BFSime
Can’t see your model? The printed reference takes priority. How to check it or send us a photo on WhatsApp.
How to check if Ref. 5183726 is the spare part for your boiler
-
Read the reference on your vessel
It must show 5 183 726 on the label or the screen print. If it is not legible, do not work it out from its shape.
-
Find the model of your boiler
It is on the rating plate. Look it up in the compatible list.
-
Compare connections and body
With the original spare part, before fitting.
-
If you are unsure, send us a photo
For the screen print: we will confirm it with you before you buy.
Send photo via WhatsApp
Symptoms that require diagnosis on this spare part (expansion vessel 5183726)
The boiler loses pressure every few days and the heating circuit needs to be refilled.
- Cause
- The expansion vessel has lost its air charge and no longer compensates for the expansion of the water when heated, causing the system to be short on pressure.
- What to do
- Check for visible leaks in radiators, bleed valves, or fittings before considering the expansion vessel acceptable.
The safety valve drips or releases water from time to time, especially when the heating has been on for a while.
- Cause
- If the expansion vessel does not absorb the expansion, the excess pressure escapes wherever it can: the safety valve.
- What to do
- Check if the dripping coincides with the start of the heating or if it is also constant with the boiler cold; that already gives a good indication.
The tank sounds solid, as if filled with water, when struck sharply with the hand on the casing.
- Cause
- When the internal membrane breaks, air is lost and the vessel fills with water to its full capacity.
- What to do
- Tap the top of the tank: if it sounds hollow, there is air; if it sounds full across the entire surface, the diaphragm is ruptured.
The pressure gauge rises quickly as soon as the burner starts, almost suddenly.
- Cause
- Without an air cushion to absorb the increase in volume, the pressure in the circuit rises directly when heated.
- What to do
- Note the cold pressure before turning on and compare it with the reading a few minutes after starting the heating.
Electrical work and opening the boiler are jobs for a technician. Repair and diagnosis
Technical sheet: expansion vessel Sime 5183726
When you open the tap or start the heating, the expansion vessel for the Metropolis DGT 25 BF boiler - Ref. 5183726 from Sime is responsible for absorbing the increase in water volume as it heats up. If this part fails, you will notice that the boiler pressure fluctuates sharply and the safety valve may start to leak. This expansion vessel is compatible with several Sime models, such as the Metropolis DGT 25 OF and the Ecomfort Plus 25 HE-EV, among others. A technician should confirm through diagnosis whether it needs to be replaced if you observe these symptoms to avoid further issues.
Frequently asked questions about the spare part expansion vessel Sime 5183726
What fault indicates that the expansion vessel of the Metropolis DGT 25 BF boiler needs to be replaced?
The technical diagnosis must confirm whether it is necessary to replace it when it loses air pressure and the boiler loses pressure or bleeds water through the safety valve.
Which models are compatible with the expansion vessel VSSIH25BF?
It is compatible with the following models: Metropolis DGT 25 BF, Metropolis DGT 25 OF, Metropolis DGT 30 BF, Metropolis Digito 25C, Metropolis Digito 25V, Metropolis Digito 30V, Ecomfort Plus 25 HE-EV, Ecomfort Plus 30 HE-EV, Brava DGT-HE 12T, Brava DGT-HE 25, Brava DGT-HE 30, Brava DGT-HE 35, Format DGT 25 BF, Format GPL DGT 25 BF, Format GPL DGT 30 BF, Format MET DGT 25 BF, Format MET DGT 30 BF, Format Low Nox 25 BF.
What symptoms indicate that the expansion vessel of my boiler needs to be replaced?
The symptoms include loss of pressure in the boiler and water discharge from the safety valve.
What is the reference for the expansion vessel for the Metropolis DGT 25 BF boiler?
To confirm compatibility, check the manufacturer's reference and the exact model of the equipment.
How many models are compatible with the expansion vessel VSSIH25BF?
A total of 18 models are compatible with this expansion vessel.
Are there documented fault codes for the expansion vessel VSSIH25BF?
No, there are no documented fault codes for this product.
How do I know if this spare part (vessel) 5183726 is the right one for my Sime boiler?
Look at the reference printed on the installed spare part (vessel): it should read 5 183 726. Then check the model on your boiler’s rating plate. This spare part (vessel) has 18 verified compatibilities, in the Sime family. If you cannot find the reference or your model is not on the list, send us a photo via WhatsApp and we will confirm it before you buy.
What does it mean that this spare part (vessel) is reconditioned?
That it is not a new spare part: it is sold inspected and tested, with a 1-year warranty. If in the end you do not install it, you have 14 days to return it.
How much does shipping cost and how long does it take to arrive?
TIPSA shipping: 24/48 working hours to mainland Spain and 2–6 working days to the EU, depending on the country. No shipping to the Balearic or Canary Islands, Ceuta or Melilla.
The exact cost appears in your cart before you pay. Check delivery times and shipping rates by country.
Can I return it if it turns out not to be the right spare part for me?
Yes. You have 14 calendar days from when you receive it to return this spare part vessel, provided it is uninstalled, unused and in its original packaging. The return shipping is at your expense, unless the error was ours or the spare part arrives faulty.
The exception is electronic boards and electronic components, for which returns are not accepted: they are inspected and prepared for a specific appliance and, once connected, their condition cannot be checked. Read the returns policy.