Fime GR00715P Smoke Extractor for Ariston Microgenus 23 MFFI - Ref. 999397
RefurbishedAristonExtractorsFIME

Fime GR00715P Smoke Extractor for Ariston Microgenus 23 MFFI - Ref. 999397

Stock · 5 units

Flue gas extractor for Ariston boilers from the 23 MFFI/MCSI range (Microgenus, Microtec, Mini, Modula, T2, and TX). Manufactured by Fime, model GR00715P according to the marking on the part itself, confirmed by external sources along with its power of 35 W. Reference 999397 also corresponds to a Chaffoteaux spare part. It is replaced when the extractor does not start, makes excessive noise, or the boiler locks due to a flue gas extraction fault.

VAT included

Compatibility

Ariston boilers compatible with reference 999397

Extractor with reference 999397. Six confirmed compatibilities: Microtec 23 MFFI and Microtec 23 MFFI GPL.

Proven compatibility

Boiler modelFamilyVerification
Ariston Microtec 23 MFFIMicrotecContrasted
Ariston Microtec 23 MFFI LPGMicrotecContrasted
Ariston Modula 23 MFFIModulaContrasted
Ariston Microgenus 23 MFFIMicrogenusContrasted
Ariston T2 23 MFFIT2Contrasted
Ariston TX 23 MFFITXContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 999397 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 999397. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the extractor 999397 resolves.

The extractor evacuates the combustion gases with forced draft. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The fan struggles to start or takes a few seconds to reach speed.

    Cause: The motor loses starting power due to internal wear or a bearing that offers more resistance than normal.

    With the boiler turned off, manually turn the shaft; if you notice a hard spot when you start to move it, it's a clear indication.

  • 02

    There is a vibration or excessive noise coming from the fan when it operates.

    Cause: The impeller unbalanced by dirt or a worn bearing causes the assembly to vibrate.

    Carefully clean the impeller if you see dust or grease buildup; sometimes that's all it takes.

  • 03

    The boiler locks out or does not ignite, indicating a combustion gas extraction fault.

    Cause: The air pressure switch does not detect the minimum depression because the fan does not reach the necessary speed.

    Check that the connection tube between the fan and the pressure switch is properly fitted, without cracks or disconnections.

  • 04

    The fan has been inactive for a long time, for example after the summer without using the heating, and now it won't start.

    Cause: The motor gets stuck due to moisture or dust accumulated on the shaft during inactivity.

    Try to manually turn the impeller with the boiler unplugged; if it's stiff or doesn't turn, confirm the seizing before replacing the part.

Fault codes for Ariston that this part resolves.

CodeFaultDiagnosis and solution
A 41Fan faultThe flue gas extractor does not start or is not detected by the electronics (no rotation or no signal), causing the boiler to lock out. Check for 230 V supply at the connector, continuity and free rotation of the fan, and that the air pressure switch closes upon start-up.
E 23Low fan speedThe extractor is rotating below the expected threshold and is not generating sufficient flow/velocity, causing a safety shutdown. Check the fan's rpm/signal, consumption, and mechanical friction, and confirm that it reaches the nominal speed and activates the pressure switch.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Ariston 999397 extractor datasheet

Catalogue reference
999397
Brand
Ariston
Type of part
Extractors
Units in stock
5 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Component manufacturer
FIME
Model code (housing)
GR00715P
Power
35 W
Frequently Asked Questions

Frequently asked questions about the extractor 999397

Is the Fime GR00715P extractor compatible with the Ariston T2 23 MFFI?
Yes, T2 23 MFFI is on the list of compatible boilers in this document.
Who manufactures the extractor with reference 999397?
Fime, according to the marking "MOD. GR00715P" engraved on the part itself, confirmed by external sources.
Does reference 999397 also serve as a spare part for a Chaffoteaux boiler?
Yes, according to external sources, that same reference also corresponds to a Chaffoteaux spare part.
What fault indicates that the extractor of the Ariston Mini 23 MCSI needs to be replaced?
That the extractor does not start, makes excessive noise, or the boiler locks out due to a flue gas extraction fault.
Can the serial number of the extractor GR00715P be read?
No; in the photographed label, the line where it would go is cut off by the edge.

Spare parts related to Ariston Microtec

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Fime GR00715P Smoke Extractor for Ariston Microgenus 23 MFFI - Ref. 999397