Bertelli & Partners SGV100 Gas Valve - Ferroli Domiproject F24 D - Ref. C1100009
Gas valve for Ferroli Divatech, Domiproject, and Domitech boilers, series C/F 24 and 32 D, manufactured by Bertelli & Partners (B&P), model SGV100. It regulates the gas flow to the burner. Operates at 24 VDC, maximum pressure 65 mbar, class B+A, with CE-0085BT0040 and DVGW certification. It is replaced when the boiler does not ignite or the gas does not reach the burner.
VAT included
Consult via WhatsAppFerroli boilers compatible with reference 39841320
Gas valve with reference 39841320. 12 verified compatibilities: F24 D and C24 D.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Ferroli F24 D | Ferroli Domiproject | Contrasted |
| Ferroli C24 D | Ferroli Domiproject | Contrasted |
| Ferroli F32 D | Ferroli Domiproject | Contrasted |
| Ferroli C32 D | Ferroli Domiproject | Contrasted |
| Ferroli F24 D | Ferroli Divatech | Contrasted |
| Ferroli C24 D | Ferroli Divatech | Contrasted |
| Ferroli F32 D | Ferroli Divatech | Contrasted |
| Ferroli C32 D | Ferroli Divatech | Contrasted |
| Ferroli F24 D | Ferroli Domitech | Contrasted |
| Ferroli C24 D | Ferroli Domitech | Contrasted |
| Ferroli F32 D | Ferroli Domitech | Contrasted |
| Ferroli C32 D | Ferroli Domitech | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. 39841320 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 39841320. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the gas valve 39841320 resolves.
The gas valve regulates and modulates the gas flow to the burner. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler does not ignite and the burner is not receiving gas.
Cause: The gas valve does not open correctly even though the control board sends the ignition signal.
Check that the valve receives 24VDC power at the moment of ignition before replacing it.
- 02
The ignition is intermittent: sometimes it lights up and other times the flame goes out a few seconds after starting.
Cause: One of the internal seals of the gas valve does not open or close consistently, and the system shuts down for safety.
Repeat several consecutive ignition attempts and note whether the fault is always the same or varies; this helps to distinguish between the flame electrode valve.
- 03
There is a smell of gas near the gas valve, especially when the boiler is off.
Cause: The internal sealing of the gas valve has failed and allows gas to pass through even when it is closed.
Apply soapy water to the threaded connections before confirming the leak, as sometimes it's a joint and not the valve.
- 04
The flame is weak or sooty even though the boiler is working.
Cause: The outlet pressure regulator of the gas valve does not maintain the working pressure within the correct range.
If you have a pressure take-off, measure the outlet pressure before replacing the complete gas valve.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the gas valve Ferroli 39841320
- Catalogue reference
- 39841320
- Brand
- Ferroli
- Type of part
- Gas valves
- Units in stock
- 4 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Maximum pressure
- Pi max 65 mbar
- Voltage
- 24 VDC
- Class
- class B+A
- Certification
- Reg. CE-0085BT0040, DVGW approved
- Country of manufacture
- Made in Italy (Verona)
- The actual manufacturer of the valve is Bertelli & Partners (B&P); Ferroli is the manufacturer of the boiler, not the valve.
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Ferroli F24 D manual (PDF)Document © Ferroli, provided as a technical reference.