SIT 845 Sigma Gas Valve Biasi Minox Ref. BI1093104
RefurbishedBiasiGas valvesSIT

SIT 845 Sigma Gas Valve Biasi Minox Ref. BI1093104

Stock · 5 units

SIT gas valve model 845 Sigma, with two solenoids (EV1 and EV2), integrated modulator and outlet pressure regulator. The SIT logo and model are printed on the piece itself. It regulates the gas entry to the boiler burner; it is replaced if the boiler does not ignite, poorly modulates the flame, or loses tightness.

VAT included

Compatibility

Biasi boilers compatible with reference BI1093104

Gas valve with reference BI1093104. A proven compatibility: Micon 24 E.

Proven compatibility

Boiler modelFamilyVerification
Biasi Micon 24 EBiasi MiconContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. BI1093104 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference BI1093104. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the gas valve BI1093104 resolves.

The gas valve regulates and modulates the gas flow to the burner. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not ignite, and there is not even an attempt at a flame.

    Cause: The EV1 and EV2 solenoid valves of the SIT gas valve do not open the gas flow to the burner.

    Check that power is reaching the gas valve at the moment of ignition before replacing it.

  • 02

    The equipment locks up right when trying to ignite, as if gas isn't reaching it.

    Cause: If the solenoid valves do not respond in time, the control unit does not detect a flame and locks the equipment for safety.

    Record the fault code from the display before disassembling the valve to confirm it indicates a flame failure.

  • 03

    The flame rises and falls irregularly without the user touching the thermostat.

    Cause: The modulator integrated into the gas valve is not properly regulating the gas flow to the burner.

    Check that the sensor or thermostat are not requesting constant power changes before blaming the gas valve.

  • 04

    There is a smell of gas in the area of the gas valve, even with the boiler turned off.

    Cause: The pressure regulator and the internal seals of the valve have lost their tightness.

    Apply soapy water to the connections before confirming that the leak is from the valve and not from a nearby joint.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the gas valve Biasi BI1093104

Catalogue reference
BI1093104
Brand
Biasi
Type of part
Gas valves
Units in stock
5 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Manufacturer
SIT
Model
845 Sigma (Code 0845070)
Maximum inlet pressure
PI max 60 mbar
Output regulation range
Po 1-37 mbar
Modulator power supply
MD max 17V DC / max. 165 mA
Solenoid valve EV1
230V-50Hz, 9.2 VA, class B
Solenoid valve EV2
230V-50Hz, 2.8 VA, class 3
Working ambient temperature
15/60 °C
Factory code / batch
Code 0845070, Lot 2537915
Frequently Asked Questions

Frequently asked questions about the gas valve BI1093104

Who manufactures the 845 Sigma gas valve for the Biasi Minox?
SIT, model 845 Sigma, according to the logo and the printing on the actual part.
Is the SIT 845 Sigma valve suitable for the Minox 32E?
Yes, it is among the compatible models along with Minox 24A/24E, 28A/28E, 3 24E, Eco 24E/28E, and Micon 24E.
What is the maximum inlet pressure that the Minox valve can handle?
60 mbar (PI max), according to the part's label.
Does the SIT 845 Sigma gas valve come with an integrated modulator?
Yes, with a maximum of 17V DC and up to 165 mA, according to the label.
How do I check if Ref. BI1093104 is the correct gas valve for my Biasi Minox?
Comparing the factory code SIT 0845070 printed on your part.
When should the gas valve of the Minox 24E be replaced?
When the boiler does not ignite, modulates the flame poorly, or loses tightness.