Honeywell Gas Valve Ferroli DomiProject F24 Ref. I39819620
Honeywell VK4105G gas valve for Ferroli boilers from the DomiProject, DOMI insert, and FEReasy ranges. It regulates the gas flow to the burner and must be used together with the S456 ignition control (version M, 230V). It is replaced when the boiler does not ignite, gets locked during startup, or there is a gas leak in the valve.
VAT included
Consult via WhatsAppFerroli boilers compatible with reference I39819620
Gas valve with reference I39819620. Seven confirmed compatibilities: Domiproject F24 and Domiproject C24.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Ferroli Domiproject F24 | Ferroli | Contrasted |
| Ferroli Domiproject C24 | Ferroli | Contrasted |
| Ferroli Domiproject F32 | Ferroli | Contrasted |
| Ferroli Domiproject C32 | Ferroli | Contrasted |
| Ferroli Domiproject F18 | Ferroli | Contrasted |
| Ferroli Fereasy C24 | Ferroli | Contrasted |
| Ferroli Domi Insert F24 | Ferroli | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if the reference I39819620 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference I39819620. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the gas valve I39819620 resolves
The gas valve regulates and modulates the gas flow to the burner. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler does not ignite the burner even though the rest of the equipment seems to be functioning normally.
Cause: The Honeywell gas valve does not open the gas flow when the ignition control S456 gives the command.
Check that the gas valve receives power at the exact moment of ignition, not before or after, before replacing it.
- 02
The equipment locks up just as it starts, almost without giving time to see the flame.
Cause: If the valve does not respond in time, the S456 control does not detect flame and immediately locks the unit for safety.
Reset the lock and observe if it takes the same amount of time to lock each time; an irregular pattern points more to the electrode or wiring than to the valve.
- 03
A gas smell is detected in the area of the gas valve, even with the boiler turned off.
Cause: The valve has lost internal sealing and allows gas to pass through even when it is closed.
Ventilate the area and apply soapy water to the joints before confirming that the leak is coming from the valve and not from a nearby connection.
- 04
A click is heard when trying to turn on, but the boiler does not ignite.
Cause: The coil of the gas valve activates the mechanism, but it does not fully open the gas flow.
Note if the click repeats in each attempt before changing the gas valve, as it helps to differentiate a mechanical fault from an electrical one.
Fault codes for Ferroli that this part resolves.
| Code | Fault | Diagnosis and solution |
|---|---|---|
| A01 | The burner does not ignite | The gas valve does not open or delivers insufficient flow during ignition; check the voltage at the valve terminals during the start-up attempt and compare pressures at the upstream/downstream ports of the valve. |
| A09 | Gas valve anomaly | Internal fault or interrupted wiring of the gas valve; check coil continuity/ohmage, power supply to the connector, and ensure there is gas flow when voltage is applied. |
| A16 | Gas valve anomaly | The boiler detects a fault in the valve (fault or wiring); check coil continuity, power supply, and replace if it does not switch/open under voltage. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the gas valve Ferroli I39819620
- Catalogue reference
- I39819620
- Brand
- Ferroli
- Type of part
- Gas valves
- Units in stock
- 4 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Type (TYPE)
- VK4105G
- CE code
- CE-0063AP3090/6
- Ambient temperature
- -15 to 60 °C
- Maximum Pressure (Pmax)
- 60 mbar
- Category/Class
- CAT III, Class B+J
- Terms of use
- Use with control S456, version M 230V
- Country of manufacture
- Made in the Netherlands
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Ferroli Domiproject F24 Manual (PDF)Document © Ferroli, provided as a technical reference.