Ferroli Bluehelix Pressure Gauge Ref. I39818210

Ferroli Bluehelix Pressure Gauge Ref. I39818210

Stock · 5 units

In Ferroli Bluehelix boilers, the pressure gauge Ref. I39818210 measures and controls the pressure of the circuit. If this part fails, you will notice incorrect readings, which can cause the boiler to lock out due to a false lack of pressure or not regulate the temperature properly. This pressure gauge is compatible with models from the DOMICOMPACT, DOMIPROJECT, and OPTIMAX ranges, among others. It is advisable to replace it when you notice that the pressure is not accurately reflected on the indicator.

VAT included

Compatibility

Ferroli boilers compatible with reference I39818210

Pressure gauge with reference I39818210. Ten confirmed compatibilities: DOMICOMPACT F24 and DOMICOMPACT F30.

Proven compatibility

Boiler modelFamilyVerification
Ferroli DOMICOMPACT F24DOMICOMPACTContrasted
Ferroli DOMICOMPACT F30DOMICOMPACTContrasted
Ferroli DOMIPROJECT F24DOMIPROJECTContrasted
Ferroli DOMIPROJECT F32DOMIPROJECTContrasted
Ferroli DOMIPROJECT D F24DOMIPROJECTContrasted
Ferroli DOMIPROJECT D F32DOMIPROJECTContrasted
Ferroli OPTIMAX HE 31 COPTIMAXContrasted
Ferroli OPTIMAX HE Plus 18SOPTIMAXContrasted
Ferroli OPTIMAX HE Plus 25SOPTIMAXContrasted
Ferroli OPTIMAX HE Plus 35SOPTIMAXContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. I39818210 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference I39818210. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the pressure gauge I39818210 resolves.

The manometer shows the pressure of the boiler circuit. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The pressure gauge stays at zero even though the boiler is full of water.

    Cause: The internal clock does not register the actual pressure because it is stuck or broken.

    Confirm that the boiler accepts water normally using the filling valve before discarding only the pressure gauge.

  • 02

    You bleed or fill the circuit and the needle doesn't react, it stays the same.

    Cause: The shaft that moves the needle is stuck and does not follow the pressure changes in the circuit.

    Repeat the filling procedure a couple of times while observing the needle; if it doesn't move, the fault is with the pressure gauge.

  • 03

    The sight glass is damaged and does not allow the pressure scale to be seen.

    Cause: A blow or the passage of time has deteriorated the display, although the measuring mechanism may still be functioning.

    Check if the damage is only to the glass (visible scratch or break) and without moisture inside, which would indicate an aesthetic issue.

  • 04

    There is a water leak at the connector where the pressure gauge is screwed in.

    Cause: The gasket or the connection thread has lost tightness due to years of pressure and heat cycles.

    Tighten the connector carefully and dry the area; if the dripping reappears, the leak is coming from the part.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Datasheet for the Ferroli I39818210 pressure gauge

Catalogue reference
I39818210
Brand
Ferroli
Type of part
Pressure gauges & aquastats
Units in stock
5 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Pressure range
0-4 bar
Frequently Asked Questions

Frequently asked questions about the pressure gauge I39818210

Is this pressure gauge suitable for a Ferroli Bluehelix?
Yes, Bluehelix is on the list of compatible boilers in this datasheet.
When should this pressure gauge be replaced in a Ferroli Domiproject F24?
If the needle doesn't respond, stays fixed at a value, or the glass is damaged.
Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Ferroli Bluehelix Pressure Gauge Ref. I39818210