Fabricgas Gas Valve Baxi Roca Victoria 20/20F - Ref. 06.273
Gas valve manufactured by Fabricgas, S.L., installed in Roca/Baxi Victoria 20/20F boilers and in the Neobit 20/20F of the same range. It regulates the flow of gas G20 at 20 mbar to the burner. The internal reference 06.273 is indicated on the label. Replacement requires confirming the fault through a technical diagnosis.
- Type of part
- Gas valves
- Status
- Refurbished
- Catalogue reference
- 122062850
- Warranty
- 1 year
Baxi Roca boilers compatible with reference 122062850
Gas valve with reference 122062850. Five confirmed compatibilities: 20/20F and 20.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Baxi Roca 20/20F | NEOBIT | Contrasted |
| Baxi Roca 20 | VICTORIA | Contrasted |
| Baxi Roca 20/20 | VICTORIA | Contrasted |
| Baxi Roca 20/20 T | VICTORIA | Contrasted |
| Baxi Roca 20/20F | VICTORIA | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if the ref. 122062850 is the part for your boiler
The part reference, model, and equipment revision must be verified against the manufacturer's documentation.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 122062850. If it is not visible, do not identify the part by its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms that require diagnosis in the gas valve 122062850
The gas valve regulates and modulates the gas flow to the burner. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler does not ignite and there is no gas reaching the burner, although the spark attempt can be heard.
Cause: The gas valve does not open the flow of gas G20 to the burner when the control board requests it.
Check that the main gas valve is open and that there is pressure before replacing the gas valve.
- 02
The flame goes out by itself a few seconds after being ignited.
Cause: A partial or intermittent closure of the gas valve leaves the burner without enough gas to maintain the flame.
Check if the cut coincides with the use of another gas point in the house before intervening in the gas valve.
- 03
The gas supply seems irregular: sometimes it ignites strongly and other times it barely lights.
Cause: Wear in the internal mechanism of the gas valve causes it not to always open the same amount of gas.
Check the inlet pressure with a manometer if you have access before declaring the valve faulty.
Fault codes Baxi Roca that require diagnosis
| Code | Fault | Technical checks |
|---|---|---|
| 40-70-90 | Power failure in gas solenoid valve. | The gas valve (block 122062850) does not open or its coil is open/stuck, so no gas reaches the burner and the PCB locks due to the absence of a flame. Check by measuring if a signal reaches the solenoid valve during ignition and the resistance of its coils; if there is a signal and the coil is out of range or does not open, replace the valve. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Baxi Roca gas valve 122062850
- Catalogue reference
- 122062850
- Uniclima internal SKU
- VGRV20/20F
- Brand
- Baxi Roca
- Type of part
- Gas valves
- Units in stock
- 3 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Part data and available documentation
Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.
- Gas and working pressure
- G20 20 mbar
- Internal reference on label
- 06.273