Fagor FE 24 AE 1N PCB · FA020155
- For 2 Fagor boilers Fagor Super Compact FE 24 E
- 230V~ · 12VA
- Check for: The boiler shows no signs, neither display nor attempt to ignite, as if it is not receiving power, The water comes out at a very irregular temperature, sometimes boiling and other times almost cold
- Out of stock for now: we will notify you when it is back
- Returns not accepted (electronic board)
- Inspected and tested, warranty 1 year
Is it compatible with your boiler?
Fagor boilers compatible with reference FA020155
- FE 24 EFagor Super Compact FE 24 E
- FE 24 AE-1NFagor Super Compact FE 24 E
Can’t see your model? The printed reference takes priority. How to check it or send us a photo on WhatsApp.
How to check if Ref. FA020155 is the spare part for your boiler
-
Read the reference on your PCB
It must show FA020155 on the label or the screen print. If it is not legible, do not work it out from its shape.
-
Find the model of your boiler
It is on the rating plate. Look it up in the compatible list.
-
Compare label, PCB and board version
With the installed board, before fitting.
-
If you are unsure, send us a photo
For the screen print: we will confirm it with you before you buy.
Send photo via WhatsApp
Symptoms that require diagnosis on this spare part (electronic board FA020155)
The boiler shows no signs, neither display nor attempt to ignite, as if it is not receiving power
- Cause
- The PCB distributes power to the rest of the equipment, and a fault in its input stage leaves everything else without power
- What to do
- Check the fuse on the PCB and use a multimeter to verify that there is voltage at the input connector before replacing it
The water comes out at a very irregular temperature, sometimes boiling and other times almost cold
- Cause
- The PCB modulates the flame according to demand, and if that function degrades, the boiler loses fine regulation
- What to do
- Check that the heat exchanger is free of scale and that the temperature sensor is clean and properly connected
The boiler attempts to ignite, the fan can be heard, but the flame does not light
- Cause
- The PCB manages the ignition sequence, and if its triggering electronics fail, it does not send a signal to the gas valve at the correct moment
- What to do
- Check the ignition electrode and its high voltage cable, as they exhibit identical symptoms
You request heat, but neither the pump nor the fan starts
- Cause
- The start command for these components is generated by the PCB, and a damaged output renders it ineffective even if the rest are functioning
- What to do
- Manually check that the pump spins freely before replacing the PCB, especially if it has been idle for months
Any work must be carried out by qualified professionals in gas and electricity. Repair and diagnosis
Error codes for Fagor that require diagnosis
Error F5: Control board fault
- Technical checks
- This symptom may be related to the part, but it does not confirm that it is faulty. A technician must check the equipment and its inspection according to the manual before deciding on a repair or replacement.
Technical sheet: electronic board Fagor FA020155
The PCB FE-24 AE 1N / FE-24 EMA / FE-24E / Super Compact FE 24 E is the control element that manages the ignition, burner modulation, pump, and safety features of the boiler. If it malfunctions, the boiler may fail to start, lock out, or operate erratically, displaying the fault code F5: Control board fault. This board is compatible with models from the Fagor Super Compact FE 24 E range, such as the FE 24 E and the FE 24 AE-1N, among others. A technician must confirm through diagnosis whether replacement is necessary when these operational issues are detected.
Spare part details
- Fagor reference
- FA020155
- Primary voltage of the transformer
- 230V~
- Transformer power
- 12VA
- Secondary of the transformer
- 14V/0.85A
- Frequency
- 50/60Hz
- Primary current of the transformer
- 80mA/T
Check the label, PCB and revision codes against the installed spare part: they are not necessarily equivalent references. Technical sheet reviewed on .
Frequently asked questions about the spare part electronic board Fagor FA020155
Is the PLCFE24AE PCB compatible with the FE-24 EMA boiler?
No, the PLCFE24AE control board is only compatible with the FE 24 E and FE 24 AE-1N models from the Fagor Super Compact FE 24 E range.
Which models are compatible with the PCB PLCFE24AE?
The compatible models are FE 24 E and FE 24 AE-1N.
What fault code is documented for the PLCFE24AE PCB?
The documented fault code for this PCB is F5.
What technical data is known about the transformer of the PLCFE24AE PCB?
The transformer data is: 230V~, 12VA, 80mA/T, secondary 14V/0.85A and 50/60Hz.
How many models in total are compatible with the PLCFE24AE PCB?
In total, there are 2 compatible models.
How do I know if this spare part (PCB) FA020155 is the right one for my Fagor boiler?
Look at the reference printed on the installed spare part (PCB): it should read FA020155. Then check the model on your boiler’s rating plate. This spare part (PCB) has two verified compatibilities, in the Fagor Super Compact FE 24 E family. If you cannot find the reference or your model is not on the list, send us a photo via WhatsApp and we will confirm it before you buy.
What does it mean that this spare part (PCB) is reconditioned?
That it is not a new spare part: it is sold inspected and tested, with a 1-year warranty. As it is an electronic component prepared for a specific boiler model, returns are not accepted.
How much does shipping cost and how long does it take to arrive?
TIPSA shipping: 24/48 working hours to mainland Spain and 2–6 working days to the EU, depending on the country. No shipping to the Balearic or Canary Islands, Ceuta or Melilla.
The exact cost appears in your cart before you pay. Check delivery times and shipping rates by country.
Can I return it if it turns out not to be the right spare part for me?
No. Returns are not accepted for electronic boards: each one is inspected, tested and prepared for a specific boiler model, and the law treats these products as personalised, with no right of withdrawal (article 103 c of the Real Decreto Legislativo 1/2007). Furthermore, once connected it is not possible to check whether it has suffered damage, so it cannot be bought to test whether the fault lies in the board.
If it arrives faulty or we send you a different reference from the one you ordered, we will take responsibility, and this spare part PCB has a 1-year warranty. Before you buy, send us a photo of the label on your spare part PCB via WhatsApp and we will confirm that it is the right one for you. Read the returns policy.
Out of stock. How will I know when it is back in stock?
Click “Book” and leave your email: we will contact you as soon as a unit is available. Signing up is free of charge.