Fagor PCB FE-24E/1 N - Ref. N03G009M8
The control PCB of the Fagor FE-24E/1 N boiler manages the ignition, burner modulation, pump, and system safety features. When it fails, the boiler may not start, become locked, or exhibit erratic behavior. Users may notice fault codes such as F5, which indicates a fault in the control board, or F10, which points to a problem with the gas valve control or closure. This part is compatible with models such as FE-24E/1 B, FE-24E H/1 N, and others. It should be replaced when these symptoms or fault codes appear.
VAT included
Consult via WhatsAppFagor boilers compatible with reference N03G009M8
PCB with reference N03G009M8. 12 verified compatibilities: FE-24E/1 N and FE-24E/1 B.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Fagor FE-24E/1 N | FE24E | Contrasted |
| Fagor FE-24E/1 B | FE24E | Contrasted |
| Fagor FE-24E H/1 N | FE24E | Contrasted |
| Fagor FE24EC/1 B | FE24E | Contrasted |
| Fagor FE24EC/1 N | FE24E | Contrasted |
| Fagor CA24E B | CA24E | Contrasted |
| Fagor CA24E N | CA24E | Contrasted |
| Fagor FA23E B | FA23E | Contrasted |
| Fagor FA23E N | FA23E | Contrasted |
| Fagor FE27E/1 B | FE27E | Contrasted |
| Fagor FE27E/1 N | FE27E | Contrasted |
| Fagor FE27ECN/1 N | FE27E | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. N03G009M8 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference N03G009M8. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the PCB N03G009M8 resolves.
The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The display shows a different fault code every little while, without you finding a pattern.
Cause: The PCB processes the readings from the boiler sensors, and if its electronics fail, it can generate errors that do not correspond to a real fault in those components.
Note the exact codes and when they appear before changing the PCB: it may point to a specific sensor.
- 02
There are clicking sounds on the PCB and the boiler turns on and off by itself intermittently.
Cause: The relays on the PCB switch the power supply to the gas valve and ignition, and if they start to fail, they cut off the supply without warning.
Listen if the clicking coincides with the equipment shutdown: if so, check the relays on the PCB before replacing the entire board.
- 03
You change the setting on the control and the boiler does not respond, it keeps doing what it wants.
Cause: The communication between the control unit and the boiler goes through the PCB, and a fault in the bus port interrupts that control.
Try to operate the boiler using its own buttons: if it responds there, the fault may be in the remote control, not in the PCB.
- 04
The water does not maintain a stable temperature, it fluctuates even if you don't touch anything.
Cause: The PCB regulates the modulation of the flame, and if that function degrades, the boiler loses precision in control.
First, rule out scale in the heat exchanger or a dirty sensor, as they produce the same effect without being the PCB.
Fault codes for Fagor that this part resolves.
| Code | Fault | Diagnosis and solution |
|---|---|---|
| F5 | Control board fault: internal fault in the electronic circuit causing the boiler to lockout. | It is the code that the FE-24E range displays when the PCB fails internally. Check after ruling out correct power supply and connections: if the F5 persists with correct wiring and sensors, the PCB (N03G009M8) is the cause and should be replaced. |
| F10 | Fault in the control or closure of the gas valve; cannot be unlocked. | Sources document that the origin may be the control circuit (the PCB) OR the gas valve itself. Verify by measuring the signal/power supply that the PCB sends to the valve: if the PCB does not correctly control the valve (signal absent or incorrect with a healthy valve), the PCB N03G009M8 is the cause. Shared cause, not exclusive to the PCB. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Fagor N03G009M8 PCB.
- Catalogue reference
- N03G009M8
- Brand
- Fagor
- Type of part
- PCBs (control boards)
- Units in stock
- 4 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Relay voltage
- 230V 50/60Hz
- Relay power/consumption
- 14V 12VA, fuse 80mA/T
- Relay code
- E5419266
- PCB reference (Fagor)
- N03G009M8, applies to Fagor CE-24E N / FE-24E N