Honeywell PCB for Boiler ZW24/30-1AE23 — Ref. 45.807.351-000 REV.C

Honeywell PCB for Boiler ZW24/30-1AE23 — Ref. 45.807.351-000 REV.C

The Honeywell control PCB for the boiler ZW24/30-1AE23 — REV.C manages the ignition, burner modulation, pump, and system safety features. When it fails, the boiler may not start, become locked, or exhibit erratic operation. The user may notice symptoms such as the reset button flashing at 0.5 Hz along with the LED at 75 °C, indicating that an ionization signal is detected but the burner does not ignite. This PCB is compatible with several models from the Junkers Euroline ZW, ZS, and NW24 ranges, among others. A technician must confirm through diagnosis whether it is necessary to replace it upon detecting faults in the ignition or the boiler's behavior.

Catalogue reference
87083002120
Warranty
1 year
VAT included OUT OF STOCK
Compatibility

Junkers boilers compatible with reference 87083002120

PCB with reference 87083002120. 22 verified compatibilities: ZW23-1AE23 and ZW23-1AE31.

Proven compatibility

Boiler modelFamilyVerification
Junkers ZW23-1AE23Junkers Euroline ZW (combi)Contrasted
Junkers ZW23-1AE31Junkers Euroline ZW (combi)Contrasted
Junkers ZW23-1KE23Junkers Euroline ZW (combi)Contrasted
Junkers ZW23-1KE31Junkers Euroline ZW (combi)Contrasted
Junkers ZW24-1ELH AE23Junkers Euroline ZW (combi)Contrasted
Junkers ZW24-1ELH AE31Junkers Euroline ZW (combi)Contrasted
Junkers ZW28-1LHKE23Junkers Euroline ZW (combi)Contrasted
Junkers ZW28-1LHKE31Junkers Euroline ZW (combi)Contrasted
Junkers ZW30-1LHAE23Junkers Euroline ZW (combi)Contrasted
Junkers ZW30-1LHAE31Junkers Euroline ZW (combi)Contrasted
Junkers ZS23-1AE23Junkers Euroline ZS (heating only)Contrasted
Junkers ZS23-1AE31Junkers Euroline ZS (heating only)Contrasted
Junkers ZS23-1KE23Junkers Euroline ZS (heating only)Contrasted
Junkers ZS23-1KE31Junkers Euroline ZS (heating only)Contrasted
Junkers NW24-1LHAE23Junkers Euroline NW24Contrasted
Junkers NW24-1LHAE31Junkers Euroline NW24Contrasted
Junkers NW24-1LHKE23Junkers Euroline NW24Contrasted
Junkers NW24-1LHKE31Junkers Euroline NW24Contrasted
Junkers NW24/28-1LHKE23Junkers Euroline NW24Contrasted
Junkers NW24/28-1LHKE31Junkers Euroline NW24Contrasted
Junkers NW24/30-1LHAE23Junkers Euroline NW24Contrasted
Junkers NW24/30-1LHAE31Junkers Euroline NW24Contrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 87083002120 is the part for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 87083002120. If it is not visible, do not identify the part by its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms that require diagnosis on the PCB 87083002120

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler shows no signs of life when the switch is turned on: no display or fan.

    Cause: The PCB is not sending power to the rest of the ignition system.

    Check the main fuse of the boiler and the differential switch of the house before blaming the PCB.

  • 02

    It triggers a fault code right at the start of the cycle, and that code does not match any actual fault detected.

    Cause: The control electronics misinterpret a signal or have a damaged output, generating errors that do not correspond to reality.

    Note the code and repeat the start three or four times; if it changes each time, the PCB is the main suspect.

  • 03

    The room thermostat is unable to turn on the boiler, but the manual button on the boiler itself does work.

    Cause: The circuit of the PCB that receives the external heat call is damaged, although the rest of the control remains operational.

    Do not force, hit, or bridge the component. Request a technical check according to the equipment manual before deciding on its replacement.

  • 04

    The boiler starts up well when cold but begins to malfunction or shut down by itself after running for a while.

    Cause: It is a typical pattern of solder joints or components on the PCB that are heat fatigued, which fail when reaching operating temperature.

    Time how long it takes to fail from startup; if it always hovers around the same time, it points more to the PCB than to a specific sensor.

  • 05

    The pump or some valve do not activate even though the rest of the ignition sequence proceeds normally.

    Cause: The output relay on the PCB that controls that component may have burned out or become stuck.

    Measure with the multimeter if voltage is reaching the connector of the affected component just when the boiler should activate it.

Junkers fault codes that require diagnosis

CodeFaultTechnical checks
Reset button flashing 0.5 Hz + LED 75 °CDuring ignition: ionisation signal is detected but the burner does not ignite.The printed circuit board (PCB 87083002120) may fail in the detection/ionisation path or be damp, causing false flame or lack of spark; check ionisation microamperage, wiring, and moisture/oxidation on the PCB before replacing it.
Reset button flashes at 4 Hz (four times per second)Control/safety fault (encoder/sensors) including possible PCB defect.Fault in the PCB (Eurotronic/PCB) in managing inputs/power supplies; check voltages at ST2 (L–N/LR–N), fuses F1/F2, and 5 V to sensors. If everything is correct and the symptom persists, replace the 87083002120.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Junkers 87083002120 PCB.

Catalogue reference
87083002120
Uniclima internal SKU
PLCZW24-30-1
Brand
Junkers
Type of part
PCBs (control boards)
Units in stock
0 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

Manufacturer (brand printed on the label)
Honeywell
PCB code (printed on PCB)
45.807.351-000 REV.C
Voltage / frequency / power
230VAC 50Hz 18VA
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the PCB 87083002120

Does this Honeywell PCB work for a EUROLINE boiler?
Yes, the EUROLINE is on the list of models compatible with this Honeywell PCB 45.807.351-000 REV.C.
Who manufactures the PCB of the boiler ZW24/30-1AE23?
Honeywell, according to the logo printed on the circuit.
What voltage and current does the PCB of the NW24-1LHAE23S28 require?
230VAC at 50Hz, with a consumption of 18VA, according to the data printed on the circuit.
Does this PCB fit the ZW28-1LHKE23?
Yes, it is included in the list of boilers from the ZW/ZS/NW range that are compatible with this PCB.