Viessmann Vitopend 100 WH0A Regulation Module Ref. 7183781

Viessmann Vitopend 100 WH0A Regulation Module Ref. 7183781

Stock · 1 unit

Electronic control module for Viessmann Vitopend 100 boilers. It is a circuit board with the Viessmann logo printed on it, identified on the component itself with the code 7183781. It is responsible for the electronic control of the boiler. It is replaced when this module fails and the unit stops responding or functioning normally.

VAT included

Compatibility

Viessmann boilers compatible with reference 7827494

PCB with reference 7827494. Two confirmed compatibilities: Vitopend 100 WH0 and Vitopend 100 WH0A.

Proven compatibility

Boiler modelFamilyVerification
Viessmann Vitopend 100 WH0Viessmann Vitopend 100Contrasted
Viessmann Vitopend 100 WH0AViessmann Vitopend 100Contrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 7827494 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 7827494. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the PCB 7827494 resolves.

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not ignite or respond to any commands, as if it were dead.

    Cause: The control module manages the ignition and safety features; if it fails, the boiler does not execute any sequence even if there is power and gas.

    Check that power is reaching the boiler and that the differential switch in the house has not tripped before considering the module.

  • 02

    The boiler fails without any visible mechanical cause: no leaks, no noises, with normal pressure.

    Cause: It is a typical symptom of a damaged control board, for example after a voltage spike or a nearby storm.

    Check if there was a power outage or recent storm and if other appliances in the house were similarly affected.

  • 03

    The room thermostat or the remote control stops communicating with the boiler.

    Cause: The control module is the one that receives and processes that communication; a fault in it breaks the link even if the control is functioning properly.

    Change the batteries in the thermostat and repeat the pairing before declaring the boiler module faulty.

  • 04

    The boiler ignites but turns off by itself erratically, without a clear pattern.

    Cause: A control module with intermittent faults may lose signals from the sensors and trigger safety shutdowns without a real reason.

    Note when it turns off (during startup, while running, when requesting domestic hot water) to rule out that another component is triggering the safety.

Fault codes Viessmann that this part solves

CodeFaultDiagnosis and solution
UFEFault in the Brennersteuergerät (burner control unit/PCB).Internal fault or defective parameterization of the control board (LGM27, ref. 7827494); check power supply, connectors/wiring, and board coding; if the fault persists, replace the board.
UF9Fault in the Brennersteuergerät (burner control unit/PCB).The control board (LGM27, ref. 7827494) detects an internal fault condition; after checking electrodes/ionisation and gas, if it reappears, check connections and replace the PCB.
UFdFault in the Brennersteuergerät (burner control unit/PCB).Recurrent internal error of the control module (LGM27, ref. 7827494); check wiring/coding and, if not restored, replace the PCB.
U02Fault in the Brennersteuergerät (burner control unit/PCB).Anomalous defect/parameterization in the control board (LGM27, ref. 7827494); check power supply and connectors, and if it reappears, replace the board.
U11Fault in the Brennersteuergerät (burner control unit/PCB).Internal fault of the electronic module (LGM27, ref. 7827494); check connections/coding and replace the PCB if the equipment does not reset.
U0CFault in the Brennersteuergerät (burner control unit/PCB).Internal error/ADC or incorrect configuration on the PCB (LGM27, ref. 7827494); check power supply, connectors X13/VR20 and, if it persists, replace the PCB.
U0dFault in the Brennersteuergerät (burner control unit/PCB).The control board (LGM27, ref. 7827494) remains in fault/locked state; after checking external causes and performing a reset, replace the board if the fault reappears.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Viessmann 7827494 PCB.

Catalogue reference
7827494
Brand
Viessmann
Type of part
PCBs (control boards)
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Code printed on the PCB
7183781
Frequently Asked Questions

Frequently asked questions about the PCB 7827494

Is this control module an original Viessmann part?
Yes; the Viessmann logo and the code 7183781 are printed on the PCB.
When should this control module of the Vitopend 100 be replaced?
When the module fails and the boiler stops responding or functioning normally.

Spare parts related to Viessmann Vitopend 100

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model