Honeywell Pressure Switch C6065FH1052:2 Saunier Duval Twin F 24 E Ref. 05600800

Honeywell Pressure Switch C6065FH1052:2 Saunier Duval Twin F 24 E Ref. 05600800

Stock · 5 units

Honeywell C6065FH1052:2 pressure switch with micro switch, also manufactured under the Yamatake brand and made in China. It is a pressure switch: it closes or opens an electrical contact (NC/NO/C scheme) according to the detected pressure difference, with a set point of 0.60 mbar and a maximum switching at 6 mbar. It is replaced when it fails and causes the boiler to lock.

VAT included

Compatibility

Saunier Duval boilers compatible with reference 05600800

Pressure switch with reference 05600800. Eight confirmed compatibilities: Thelia Twin 28 E and Thelia 30 E.

Proven compatibility

Boiler modelFamilyVerification
Saunier Duval Thelia Twin 28 EThelia TwinContrasted
Saunier Duval Thelia 30 ETheliaContrasted
Saunier Duval Opalia F 13 EOpaliaContrasted
Saunier Duval Opalia X 13OpaliaContrasted
Saunier Duval Sylva FF 24 ESylvaContrasted
Saunier Duval Twin F 24 ETwinContrasted
Saunier Duval Twin F 28 ETwinContrasted
Saunier Duval Master Twin L 85 EMaster TwinContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 05600800 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 05600800. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the pressure switch 05600800 resolves.

The pressure switch controls the air or water pressure to authorize operation. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler tries to ignite, the fan spins, but it cuts off immediately and gets locked.

    Cause: The pressure switch does not close the contact that confirms the air depression, and the PCB cuts off the gas as a safety measure.

    Check that the fan reaches its normal speed, without slow starts or noise, before replacing the pressure switch.

  • 02

    The fault indicator is flashing with a ventilation or flue extraction fault code.

    Cause: It is the typical signal that the pressure switch has not made the contact that the control board expects to authorize the ignition.

    Check the silicone tubes that go from the pressure switch to the flue: ensure they are not bent, cracked, or disconnected.

  • 03

    After cleaning or touching the flue outlet, the boiler started to lock out more frequently.

    Cause: Any partial obstruction in the flue duct reduces the pressure, and the pressure switch correctly does not close the contact.

    Check the flue gas outlet to the outside for any obstructions (nest, ice, dirt) before considering the part.

  • 04

    The fault mainly occurs with strong winds or gusts of air near the flue outlet.

    Cause: External air currents can alter the pressure in the duct just enough for the pressure switch to stop closing the contact.

    Note if the blockage coincides with windy days; it helps to determine if the problem is the part or the flue installation.

Fault codes from Saunier Duval that this spare part resolves.

CodeFaultDiagnosis and solution
02Air fault (SRC or pressure switch).The air pressure switch does not switch with the fan due to lack of depression or obstructed pipes/tappings; check the continuity of the pressure switch during start-up and measure depression with a manometer at the pressure switch tappings.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Saunier Duval Pressure Switch Datasheet 05600800

MPN verified on the label
C6065FH1052:2
Catalogue reference
05600800
Brand
Saunier Duval
Type of part
Pressure switches
Units in stock
5 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Manufacturer
Honeywell (also labeled Yamatake)
Component code
C6065FH1052:2
Contact voltage
250V~
Associated capacitor
1.5(0.5) µF
Contact diagram
NC/NO/C
Set point
ΔP=0.60 mbar
Maximum switching pressure
max. 6 mbar
Partial fault code CE
CE-0063A...
Place of manufacture
Made in China
Internal microswitch (code)
V-561QR-041
Internal microswitch (load)
1.5A-250VAC
Frequently Asked Questions

Frequently asked questions about the pressure switch 05600800

Is this Honeywell C6065FH1052:2 pressure switch suitable for the Saunier Duval Twin F 24 E?
Yes, the Twin F 24 E is on the list of compatible boilers for this part, reference 05600800.
Who manufactures the pressure switch Ref. 05600800 for the Twin F 24 E?
Honeywell, with double Yamatake marking on the label.
What pressure is the pressure switch C6065FH1052:2 set to?
0.60 mbar, with a maximum allowable switching of 6 mbar, according to the label.
What fault does the pressure switch of the Master Twin L 85 E resolve?
Correct the boiler lockout that occurs when the pressure switch fails and does not open or close its contact properly.

Spare parts related to Saunier Duval Opalia

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Honeywell Pressure Switch C6065FH1052:2 Saunier Duval Twin F 24 E Ref. 05600800