Saunier Duval Thelia Twin 28 E Water Pressure Switch CEME Ref. 05600700
CEME water pressure switch (series 5611/VAP-DR) for Saunier Duval boilers from the Thelia, Themis, Twin, Sylva, and Master Twin range. It controls the pressure of the hydraulic circuit and shuts off the boiler if it goes out of the working range, preventing it from operating without sufficient water pressure. Range 0.2-6 bar, differential 0.1-0.8 bar.
VAT included
Consult via WhatsAppSaunier Duval boilers compatible with reference 05600700
Pressure switch with reference 05600700. Ten verified compatibilities: Thelia Twin 28 and Thelia Twin 28 E.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Saunier Duval Thelia Twin 28 | Thelia Twin | Contrasted |
| Saunier Duval Thelia Twin 28 E | Thelia Twin | Contrasted |
| Saunier Duval Thelia 30 E | Thelia | Contrasted |
| Saunier Duval Themis Twin 28 | Themis Twin | Contrasted |
| Saunier Duval Themis Twin 28 E | Themis Twin | Contrasted |
| Saunier Duval Sylva 24 E | Sylva | Contrasted |
| Saunier Duval Sylva FF 24 E | Sylva | Contrasted |
| Saunier Duval MasterTwin L85 E | Master Twin | Contrasted |
| Saunier Duval Twin C 28 E | Twin C / Twin F | Contrasted |
| Saunier Duval Twin F 28 E | Twin C / Twin F | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. 05600700 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 05600700. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the pressure switch 05600700 resolves.
The pressure switch controls the air or water pressure to authorize operation. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler locks up when starting or does not start, and a warning of low water pressure appears on the display.
Cause: The pressure switch does not detect the correct pressure in the circuit or gives an incorrect reading, and the control board prevents ignition to protect the boiler.
Check the manometer: if it reads below 1 bar, fill the circuit with the filling key and test again before replacing the pressure switch.
- 02
The boiler gradually loses pressure, or the pressure warning fluctuates on its own, even though the circuit is bled.
Cause: A pressure switch that does not close the contact properly can give erratic readings that the control board interprets as a real pressure drop.
First, rule out a leak in the expansion vessel or the safety valve; if the pressure gauge remains stable and the warning persists, suspect the pressure switch.
- 03
The reset works sometimes and sometimes it doesn't, without a clear pattern.
Cause: The internal contact may get stuck or make a poor connection due to wear, causing intermittent faults that do not correspond to the actual pressure of the circuit.
Note if the fault always coincides with the same pressure level on the manometer; if it triggers at a correct pressure, point to the pressure switch.
- 04
The boiler works well when cold but locks up when heating.
Cause: When heating, the water pressure increases due to expansion; if the pressure switch differential is misadjusted, it may trigger outside its normal operating range.
Check with the manometer how much the pressure rises when heating: if it frequently exceeds 3 bar, first check the expansion vessel, not the pressure switch.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Datasheet for Saunier Duval pressure switch 05600700
- Catalogue reference
- 05600700
- Brand
- Saunier Duval
- Type of part
- Pressure switches
- Units in stock
- 5 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Type
- PN
- Pressure range
- 0.2 - 6 bar
- Differential
- 0.1 - 0.8 bar
- Maximum ambient temperature
- 125°C
- Series (manufacturer code)
- 5611/VAP-DR
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Saunier Duval TWIN C 28 E Manual (PDF)Document © Saunier Duval, provided as a technical reference.