C.E.M.E. Water Pressure Switch Renova Hermann Micra 23 SE - Ref. HE049003163
RefurbishedRenovaPressure switchesC.E.M.E.

C.E.M.E. Water Pressure Switch Renova Hermann Micra 23 SE - Ref. HE049003163

Stock · 4 units

Water pressure switch manufactured by C.E.M.E. (label information), which shuts off the burner if the circuit pressure does not reach the correct range. Set between 0.7 and 1.8 bar, it consumes 12VA and supports contacts of 13A and 9A at 250V~, up to 120°C. It is replaced when the boiler locks due to pressure failure or does not ignite.

VAT included

Compatibility

Renova boilers compatible with reference HE049003163

Pressure switch with reference HE049003163. 15 verified compatibilities: Micra Condens 26 and Micra 2 24 E.

Proven compatibility

Boiler modelFamilyVerification
Renova Micra Condens 26HermannContrasted
Renova Micra 2 24 EHermannContrasted
Renova Micra 2 24 SEHermannContrasted
Renova Micra 2 24-30 SEHermannContrasted
Renova Micra 23 SEHermannContrasted
Renova Micra 24 EHermannContrasted
Renova Micra 24 SEHermannContrasted
Renova Habitat 23 SEHermannContrasted
Renova Habitat Plus 23 EHermannContrasted
Renova Habitat2 23 EHermannContrasted
Renova Master Inox 30 SEHermannContrasted
Renova Supermaster 28-30 SEHermannContrasted
Renova Supermicra 28 EHermannContrasted
Renova Supermicra 30 SEHermannContrasted
Renova Supermicra Ecoplus 24 SEHermannContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. HE049003163 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference HE049003163. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the pressure switch HE049003163 resolves.

The pressure switch controls the air or water pressure to authorize operation. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The burner does not ignite even though the pressure on the manometer seems correct.

    Cause: The pressure switch does not close the contact because it is worn out and does not detect the correct pressure, even though it may look normal visually.

    Measure the pressure with the manometer; it should be between 0.7 and 1.8 bar. If it is within that range and the burner still does not ignite, the problem may be with the pressure switch.

  • 02

    The boiler repeatedly locks out due to water pressure, even after refilling it.

    Cause: The internal contact of the pressure switch can degrade over time and fail to close properly, causing lockouts.

    Fill the boiler to a normal pressure, wait a few minutes, and check if the lockout occurs again; if it does, it is not a real pressure problem.

  • 03

    The ignition is intermittent: sometimes it starts and other times it locks out at the same pressure.

    Cause: The pressure switch may lose accuracy if it operates continuously near its temperature limit of 120°C.

    Check if the fault occurs more often when the boiler is hot than when it is cold; if so, the pressure switch could be fatigued by the temperature.

  • 04

    The boiler shows a pressure lock without visible leaks in the installation.

    Cause: The pressure switch may be permanently open due to a mechanical fault, even if the pressure is correct.

    Check for leaks in radiators, bleed valves, and safety group; if there is no pressure loss, the pressure switch is the main suspect.

Fault codes for Renova that this spare part resolves.

CodeFaultDiagnosis and solution
10Insufficient water pressure (intervention of the water shortage pressure switch).The water pressure switch opens due to low pressure or is faulty, causing the PCB to interpret a lack of water. Check the actual pressure with a manometer and the continuity/closure of the pressure switch at its threshold (≈0.5–1.2 bar) and inspect the wiring.
F.22Installation pressure too low (shutdown due to lack of water).A faulty or disconnected water pressure sensor/pressure switch can report low pressure and cause a lockout. Check the actual pressure and the sensor's signal/voltage and its wiring harness, comparing with a manometer.
F.73Error: water pressure sensor not connected or short-circuited (signal too low).The water sensor/pressure switch does not deliver a valid signal or is shorted, so the electronics do not "see" pressure. Check power supply (≈5 V), wiring continuity, and the sensor's output signal to the PCB.
F.74Error: electrical problem with the water pressure sensor (signal out of range/high).Shorts at 5/24 V or internal fault of the sensor/pressure switch cause invalid reading. Check with a multimeter for possible short circuits/voltage in sensor lines and replace if necessary.
F.75Fault: pressure sensor (defective pressure capsule).The manometric capsule of the sensor/pressure switch is damaged and delivers an incorrect signal. Compare the sensor reading with the actual pressure, and if it does not vary with pressure changes, replace the component.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Datasheet for the Renova pressure switch HE049003163

Catalogue reference
HE049003163
Brand
Renova
Type of part
Pressure switches
Units in stock
4 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Manufacturer (label)
C.E.M.E.
Model
PC84 (possible 'PC 84')
Power
12VA
Setting range
0.7 ÷ 1.8 bar
Maximum temperature
120°C
Contacts
NC 13/250V~, NO 9/250V~ (digits uncertain due to text rotation on the label)
Certifications
CE, UL
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the pressure switch HE049003163

What pressure does the pressure switch of the Hermann Micra 23 SE support before cutting off the burner?
Pressure between 0.7 and 1.8 bar, according to the part label.
Does the pressure switch of the Micra 23 SE also fit the Hermann Habitat Plus 23 E?
Yes, the Habitat Plus 23 E is among the listed compatible models.
What contacts does the pressure switch of the Hermann Supermicra 30 SE have?
NC 13A and NO 9A at 250V~, although the digits are difficult to read due to the rotation of the text on the label.
Who manufactures the pressure switch for the Hermann Master Inox 30 SE?
C.E.M.E., as stated directly on the part's label.
What is the maximum temperature that the pressure switch of the Hermann Micra Condens 26 can withstand?
Up to 120°C, according to the marking on the body.

Spare parts related to Renova Hermann

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
C.E.M.E. Water Pressure Switch Renova Hermann Micra 23 SE - Ref. HE049003163