Saunier Duval Micraplus NOx 24 Circulating Pump Ref. 0010032795
The Saunier Duval Micraplus NOX 24 circulator pump is responsible for moving water through the heating circuit of your boiler. If it fails, you will notice cold radiators, strange noises, overheating, or blockages due to lack of circulation. This pump is compatible with several models, including the Micraplus 24, Micraplus NOX 25, and Micraplus 24 SE A/1, among others. It is advisable to replace it when you experience the mentioned symptoms or if the fault codes F.22, F.23, or F.24 appear.
VAT included
Consult via WhatsAppHermann boilers compatible with reference 0010032795
Circulating pump with reference 0010032795. Three confirmed compatibilities: Micraplus 24 and Micraplus NOX 25.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Hermann Micraplus 24 | Hermann Micraplus (= Saunier Duval Micraplus, Hermann generation) | Contrasted |
| Hermann Micraplus NOx 25 | Hermann Micraplus (= Saunier Duval Micraplus, Hermann generation) | Contrasted |
| Hermann Micraplus 24 SE A/1 | Hermann Micraplus (= Saunier Duval Micraplus, Hermann generation) | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. 0010032795 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 0010032795. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the circulator pump 0010032795 resolves.
The circulation pump circulates the water in the heating circuit. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The pump does not start, it doesn't even make a buzzing sound when trying to.
Cause: The rotor has seized due to limescale or because it has been idle for a long time, which is typical in these two-speed pumps after the summer.
Before replacing it, try to unlock the shaft with a flat screwdriver on the front screw, with the boiler unplugged.
- 02
The pump makes noise, a constant buzzing or rattling.
Cause: It is usually air trapped in the circuit or the internal bearings that are already worn out.
Bleed the radiators and the automatic bleeder of the boiler before declaring the pump faulty.
- 03
The water is not circulating and the radiators are not heating even though the burner is ignited.
Cause: The impeller may be blocked by scale or sludge, or the pump has lost power in both speeds.
Check that the shut-off valves of the installation are open and that the selector is set to high speed.
- 04
The pump starts but stops on its own after a short while.
Cause: In two-speed pumps, this is often due to an internal thermal cut-off caused by overexertion, frequently triggered by air or dirt in the circuit.
Leave the installation bled for a couple of days and check if the cut repeats before replacing the pump.
Fault codes Hermann that this part solves
| Code | Fault | Diagnosis and solution |
|---|---|---|
| F.22 | Safety shutdown: lack of water in the boiler | The pump is not operating or is disconnected (cable to the pump is loose/defective), so there is no circulation and the equipment interprets a lack of water. Check voltage/continuity at the pump terminals and force it in test mode to check start-up and pressure/noise variation. |
| F.23 | Safety shutdown: temperature variation too large (NTC1/NTC2) | Blocked or low-power pump causes a large difference between flow and return. Check that the pump is rotating (consumption/noise/rotor), bleed the system, and check pump adjustment/speed. |
| F.24 | Safety shutdown: temperature rise too fast | Blocked/insufficient pump or presence of air prevents heat dissipation and the flow rises very quickly. Verify actual pump start-up, bleed the circuit, and check speed/obstructions. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the circulation pump Hermann 0010032795
- Catalogue reference
- 0010032795
- Brand
- Hermann
- Type of part
- Pumps
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Voltage and frequency
- ~230V-50Hz
- Thermal class
- Class F / TF95
- Protection rating
- IP44
- Nominal pressure
- PN3
- Condenser
- 2.6 µF
- Current and power speed I
- 0.29A / 64W
- Current and Power Speed II
- 0.38A / 85W
- Type
- HB15/6.7-2
- Reference on label
- 4000126459
- Unit number
- 4514422
- Week/year code
- 13W07