Fagor Safety Valve FEE 20 2 B Ref. N57G001M5
The safety valve releases water if the circuit pressure exceeds the usual limit of 3 bar. This part is from the brand Fagor and has the reference N57G001M5. When it fails, it may leak continuously or not discharge properly, which can cause an increase in pressure in the system. It is installed in boilers such as the FEE-20, FEE-20D-1, FEE-20F-1, among others from the CE, FE, FEE, FA, FEB, and CA ranges. It is recommended to replace it upon noticing these symptoms or if the valve shows visible damage.
VAT included
Consult via WhatsAppFagor boilers compatible with reference N57G001M5
Safety valve with reference N57G001M5. 32 verified compatibilities: CE-20E-1 N and CE-20E-1 GLP.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Fagor CE-20E-1 N | CE | Contrasted |
| Fagor CE-20E-1 LPG | CE | Contrasted |
| Fagor FE-20E-1 | FE | Contrasted |
| Fagor FE-20EF | FE | Contrasted |
| Fagor FE-20EGLP | FE | Contrasted |
| Fagor FE-28E-1 | FE | Contrasted |
| Fagor FE-28EF-1 | FE | Contrasted |
| Fagor FEE-20 | FEE | Contrasted |
| Fagor FEE-20D-1 | FEE | Contrasted |
| Fagor FEE-20F-1 | FEE | Contrasted |
| Fagor FEE-28 | FEE | Contrasted |
| Fagor FA-20EN | FA | Contrasted |
| Fagor FA-20EF-1 | FA | Contrasted |
| Fagor FA-20E2N | FA | Contrasted |
| Fagor FA-20E2F-1 | FA | Contrasted |
| Fagor FA-20EGLP | FA | Contrasted |
| Fagor FA-20ET | FA | Contrasted |
| Fagor FA-20N | FA | Contrasted |
| Fagor FA-20GLP | FA | Contrasted |
| Fagor FA-15-20 | FA | Contrasted |
| Fagor FEB-20E-1 | FEB | Contrasted |
| Fagor FEB-20EF-1 | FEB | Contrasted |
| Fagor FEB-20EH-1 | FEB | Contrasted |
| Fagor FEB-20EUK-1 | FEB | Contrasted |
| Fagor CA-20EN | CA | Contrasted |
| Fagor CA-20EGLP | CA | Contrasted |
| Fagor CA-20N | CA | Contrasted |
| Fagor CA-20GLP | CA | Contrasted |
| Fagor FC-15N | FC | Contrasted |
| Fagor FC-15GLP | FC | Contrasted |
| Fagor FC-15LN | FC | Contrasted |
| Fagor FC-15LGLP | FC | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. N57G001M5 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference N57G001M5. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the safety valve N57G001M5 resolves.
The safety valve releases pressure when the circuit exceeds its setting. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The valve is constantly dripping water from the discharge tube, even with the boiler cold.
Cause: The internal seat of the gas valve does not seal properly after having operated at some point, or it has worn out with use.
Check the pressure on the gauge with the boiler cold: if it is below approximately 1.5 bar and it still drips, it points to the valve.
- 02
The valve releases water just when the boiler heats up and the pressure rises.
Cause: It's its safety function, but if it activates earlier than usual, another component in the circuit might be failing and causing it to trip.
Check the cold pressure of the circuit and the expansion vessel before assuming the gas valve is faulty, as a discharged vessel can also cause this symptom.
- 03
The valve never releases water, not even when the pressure rises above normal.
Cause: The mechanism has seized up due to lime scale or lack of use and does not release even though it should.
If it has a manual bleed lever, carefully activate it to check if it releases water and then close it properly again.
- 04
There is a visible and permanent leak in the discharge pipe, with lime stains underneath.
Cause: The internal seat is worn and no longer closes after having released pressure on a previous occasion.
Dry the area around the discharge pipe and check if it starts leaking again after a few hours with the installation cold.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Fagor N57G001M5 safety valve.
- Catalogue reference
- N57G001M5
- Brand
- Fagor
- Type of part
- Safety valves
- Units in stock
- 3 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Body material
- Brass