Ignition Transformer Imeco Fagor MF 16 CE Type 697250-64
Ignition transformer for Fagor boiler MF 16 CE. Manufactured by Imeco S.r.l. (Italy), according to the piece's labeling: Type 697250-64, 220-240 V, 50/60 Hz, 0.7 VA, thermal class T60. It is part of the ignition circuit; it is replaced when the start-up fails and the electrode or the control unit is ruled out.
VAT included
Consult via WhatsAppCompatible Fagor boilers
Ignition transformer. A proven compatibility: MF 16 CE.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Fagor MF 16 CE | Fagor | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if it is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference —. If it is not visible, do not identify the part by its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the ignition transformer resolves
The ignition transformer generates the high voltage for the spark of the electrodes. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The burner does not ignite on any attempt.
Cause: The transformer does not deliver the necessary current for the electrode to generate the arc.
Check that the high voltage cable is properly connected at both ends before replacing the part.
- 02
The ignition attempt can be heard, but the burner does not ignite.
Cause: The transformer may be producing a spark, but it is too weak to ignite the gas and air mixture.
Visually check for a spark at the electrode during the attempt and observe whether it is continuous or intermittent.
- 03
After a failed attempt, the boiler locks out and does not start until you reset it.
Cause: It is the safety response of the control board when it does not detect a flame during the ignition time.
Test the reset and observe if the fault always occurs at the same point in the ignition cycle.
- 04
The boiler starts up well when cold but fails after running for a while.
Cause: The transformer insulation deteriorates with heat and loses output current when hot.
Repeat the ignition test with the boiler cold and again after prolonged use to see if the fault depends on the temperature.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Fagor ignition transformer datasheet
- Brand
- Fagor
- Type of part
- Transformers
- Units in stock
- 4 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- manufacturer
- IMECO S.r.l. (Italy)
- type (code)
- 697250-64
- voltage
- 220-240 V
- frequency
- 50/60 Hz
- power
- 0.7 VA
- Thermal class
- T60
- The current catalog does not provide a commercial reference for this part; identify it by the printed code Type 697250-64.
- The manufacturer printed on this unit is Imeco, different from Ineco, which appears on other similar pieces from this same batch; they are not the same manufacturer.