Honeywell UC6012 3-Way Valve Actuator - Saunier Duval Master Twin L85E
Actuator (motor) for the 3-way solenoid valve, manufactured by Honeywell, model UC6012, with double insulation. It operates at 200-240 VAC 50/60 Hz, with a stroke time of 6 seconds and a consumption of 6 VA. It is installed in Saunier Duval boilers from the Master Twin, Sylva, Thelia, Thema, and Themis ranges. It is replaced when the actuator does not move the valve and the boiler does not switch between domestic hot water and heating.
VAT included
Consult via WhatsAppSaunier Duval boilers compatible with reference 05133500
3-way valve with reference 05133500. Four confirmed compatibilities: Thelia Twin 28 and Thelia Twin 28 E.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Saunier Duval Thelia Twin 28 | Thelia Twin | Contrasted |
| Saunier Duval Thelia Twin 28 E | Thelia Twin | Contrasted |
| Saunier Duval Themis Twin 28 | Themis Twin | Contrasted |
| Saunier Duval Themis Twin 28 E | Themis Twin | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. 05133500 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 05133500. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the 3-way valve 05133500 resolves.
The 3-way valve diverts water between heating and domestic hot water. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler does not switch between domestic hot water and heating.
Cause: The actuator does not turn the valve when it receives the command, so the water continues to circulate through the same circuit.
Check if the actuator physically moves when opening a hot water tap; if nothing turns, the fault points to the motor or its power supply.
- 02
It remains fixed on a single service (domestic hot water or heating) even when the other is requested.
Cause: The internal gear of the actuator has worn out or become disengaged and no longer drives the valve stem.
With the actuator removed, check if the valve turns smoothly by hand; if it does, the problem is only with the actuator.
- 03
Motor noise without the valve moving
Cause: The gear motor turns but the pinion has lost engagement with the valve shaft.
Listen to see if the buzzing stops after a few seconds (motor reaching full speed) or continues indefinitely (loose gear).
- 04
Boiler warning or error related to the 3-way valve or its actuator
Cause: The control unit does not detect that the actuator has completed its cycle and locks the boiler for safety reasons.
Write down the exact code displayed on the screen before replacing the part, to confirm that it points to the actuator and not another component.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Saunier Duval 05133500 three-way valve.
- Catalogue reference
- 05133500
- Brand
- Saunier Duval
- Type of part
- 3-way valves
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Manufacturer
- Honeywell
- Product code
- UC6012
- Voltage and frequency
- 200-240 VAC 50/60 Hz
- Power
- 6 VA
- Race time
- 6 seconds
- Degree of protection
- IP40
- Thermal class
- T6S TS110
- Country of manufacture
- Canada
- Batch code
- 9901
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Saunier Duval THELIA TWIN 28 E Manual (PDF)Document © Saunier Duval, provided as a technical reference.