Three-Way Valve Actuator Motor Saunier Duval ThemaClassic C24E - Ref. 31650002.00
Three-way valve actuator motor that diverts the circuit between heating and domestic hot water in Saunier Duval ThemaClassic boilers. Operates at 220V-240V, 50Hz, thermal class T70. It is replaced when the boiler does not switch between services, gets stuck in one position, or the motor does not respond.
VAT included
Consult via WhatsAppSaunier Duval boilers compatible with reference S5720600
3-way valve with reference S5720600. 25 confirmed compatibilities: C 24 E and F 24 E.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Saunier Duval C 24 E | ThemaClassic | Contrasted |
| Saunier Duval F 24 E | ThemaClassic | Contrasted |
| Saunier Duval F 25 E | ThemaClassic | Contrasted |
| Saunier Duval C 25 E | ThemaClassic | Contrasted |
| Saunier Duval F 30 E | ThemaClassic | Contrasted |
| Saunier Duval F AS 25 E | ThemaClassic | Contrasted |
| Saunier Duval F AS 30 E | ThemaClassic | Contrasted |
| Saunier Duval C 24 E | Themafast | Contrasted |
| Saunier Duval F 24 E | Themafast | Contrasted |
| Saunier Duval F 30 E | Themafast | Contrasted |
| Saunier Duval C 28 E | Themafast | Contrasted |
| Saunier Duval C 28 E | Isofast | Contrasted |
| Saunier Duval F 28 E | Isofast | Contrasted |
| Saunier Duval C 35 E | Isofast | Contrasted |
| Saunier Duval F 35 E | Isofast | Contrasted |
| Saunier Duval C 28 E | Isomax | Contrasted |
| Saunier Duval F 28 E | Isomax | Contrasted |
| Saunier Duval C 28 E2 | Isomax | Contrasted |
| Saunier Duval F 28 E2 | Isomax | Contrasted |
| Saunier Duval C 24 EA | Isotwin | Contrasted |
| Saunier Duval C 28 EA | Isotwin | Contrasted |
| Saunier Duval F 24 EA | Isotwin | Contrasted |
| Saunier Duval F 28 EA | Isotwin | Contrasted |
| Saunier Duval C 24 E | Combitek | Contrasted |
| Saunier Duval F 24 E | Combitek | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. S5720600 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference S5720600. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the S5720600 three-way valve resolves.
The 3-way valve diverts water between heating and domestic hot water. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
You request heating and the boiler turns on, but the radiators take a long time to heat up or do not heat at all.
Cause: The valve motor has not completed the turn towards the heating circuit.
Check that the radiators are not airlocked (bleed) before ruling out the gas valve: the symptom is similar.
- 02
The domestic hot water from the tap comes out cold or lukewarm even though the boiler is on and without other faults.
Cause: The valve is stuck in the heating position and does not switch to domestic hot water when the tap is opened.
Turn off the heating completely and test only the tap: if it still doesn't heat, the problem is in the circuit switch.
- 03
You hear a motor straining or a metallic clicking sound every time it switches service.
Cause: It is typical of worn internal gearing to slip before engaging in the correct position.
Check if the noise always coincides with the circuit change and not with the activation of the extractor or the pump.
- 04
The valve gets stuck halfway, and the boiler can't decide whether to provide heating or domestic hot water.
Cause: The shaft may be seized due to lime deposits, preventing the motor from completing its cycle.
With the installation cold, try to manually move the motor shaft (disconnected from power) and see if there is a point of blockage.
- 05
A drip or moisture stain appears in the lower area of the valve, unrelated to other leaks from the boiler.
Cause: The seals of the valve body give way with use and temperature, even if the motor works well.
Mark the dry area, run the boiler for a while, and check if the moisture reappears right there.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Saunier Duval S5720600 three-way valve.
- Catalogue reference
- S5720600
- Brand
- Saunier Duval
- Type of part
- 3-way valves
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Voltage
- 220V-240V
- Frequency
- 50Hz
- Thermal class
- T70
- Actuator code
- 31650002.00
- Secondary code
- 96458148 286
- Code date
- 08/07/02