3-Way Valve Actuator Motor Saunier Duval Isomax F 28 E Ref. 16511/10.00
Actuator motor for the three-way valve Saunier Duval, reference 16511/10.00. This part is responsible for switching the water between the heating circuit and the domestic hot water circuit. If it fails, you will notice that there is hot water but no heating, or vice versa, or that both circuits are mixing. It is compatible with boilers such as the C 28 E, F 28 E, among others from the ThemaClassic, Themafast, Isofast, Isomax, Isotwin, and Combitek ranges. It should be replaced when you experience these operational issues.
VAT included
Consult via WhatsAppSaunier Duval boilers compatible with reference S5720600
3-way valve with reference S5720600. 25 confirmed compatibilities: C 24 E and F 24 E.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Saunier Duval C 24 E | ThemaClassic | Contrasted |
| Saunier Duval F 24 E | ThemaClassic | Contrasted |
| Saunier Duval F 25 E | ThemaClassic | Contrasted |
| Saunier Duval C 25 E | ThemaClassic | Contrasted |
| Saunier Duval F 30 E | ThemaClassic | Contrasted |
| Saunier Duval F AS 25 E | ThemaClassic | Contrasted |
| Saunier Duval F AS 30 E | ThemaClassic | Contrasted |
| Saunier Duval C 24 E | Themafast | Contrasted |
| Saunier Duval F 24 E | Themafast | Contrasted |
| Saunier Duval F 30 E | Themafast | Contrasted |
| Saunier Duval C 28 E | Themafast | Contrasted |
| Saunier Duval C 28 E | Isofast | Contrasted |
| Saunier Duval F 28 E | Isofast | Contrasted |
| Saunier Duval C 35 E | Isofast | Contrasted |
| Saunier Duval F 35 E | Isofast | Contrasted |
| Saunier Duval C 28 E | Isomax | Contrasted |
| Saunier Duval F 28 E | Isomax | Contrasted |
| Saunier Duval C 28 E2 | Isomax | Contrasted |
| Saunier Duval F 28 E2 | Isomax | Contrasted |
| Saunier Duval C 24 EA | Isotwin | Contrasted |
| Saunier Duval C 28 EA | Isotwin | Contrasted |
| Saunier Duval F 24 EA | Isotwin | Contrasted |
| Saunier Duval F 28 EA | Isotwin | Contrasted |
| Saunier Duval C 24 E | Combitek | Contrasted |
| Saunier Duval F 24 E | Combitek | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. S5720600 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference S5720600. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the S5720600 three-way valve resolves.
The 3-way valve diverts water between heating and domestic hot water. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler heats the radiators but no hot water comes out when the tap is opened, or vice versa.
Cause: The motor does not move the valve stem to the DHW position and the water remains in the heating circuit.
Check manually, with the boiler unplugged, that the valve stem moves freely and is not stuck before considering the fault resolved.
- 02
The wrong circuit heats up: you request domestic hot water and it heats the heating, or vice versa.
Cause: The actuator has become stuck in one position and does not switch between the two circuits.
Listen to see if you hear the click or hum of the motor starting when requesting domestic hot water; if you don't hear anything, check the actuator's power supply first.
- 03
A buzzing or rattling noise is heard in the valve when the boiler tries to switch modes.
Cause: The motor turns but does not complete the cycle, usually due to a damaged internal gear or a seized stem.
Check for lime scale or dirt blocking the valve body before replacing just the motor.
- 04
The boiler takes a long time to provide hot water or seems to distribute between heating and domestic hot water simultaneously.
Cause: The switching is not clean, and the system mixes the two circuits instead of isolating them.
Verify that the actuator actually reaches the end of its travel, not just that it starts moving.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Saunier Duval S5720600 three-way valve.
- Catalogue reference
- S5720600
- Brand
- Saunier Duval
- Type of part
- 3-way valves
- Units in stock
- 5 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Secondary code
- 105901
- Voltage
- 220V - 240V
- Frequency
- 50 Hz
- Thermal class
- T70
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Saunier Duval F 28 E Manual (PDF)Document © Saunier Duval, provided as a technical reference.