Honeywell VC6012 3-Way Valve Actuator Motor SE Range Ref. 2000803043

Honeywell VC6012 3-Way Valve Actuator Motor SE Range Ref. 2000803043

Honeywell VC6012 actuator motor for the 3-way valve of boilers in the SE range (ACQUAPLUS, COMPACT, ECOLASER, EURA, EURA TOP, MASTER, SUPERMASTER). It moves the valve between heating and domestic hot water; if it fails, the boiler may be left without DHW, without heating, or may switch poorly between both. The replacement requires first confirming the fault of the part through technical diagnosis, even when the motor does not turn, makes noise, or the valve is stuck halfway.

Type of part
3-way valves
Catalogue reference
2000803043
Warranty
1 year
VAT included Stock · 3 units
Compatibility

Renova boilers compatible with reference 2000803043

Three-way valve with reference 2000803043. Eight confirmed compatibilities: 29 SE and 32 SE.

Proven compatibility

Boiler modelFamilyVerification
Renova 29 SEACQUAPLUSContrasted
Renova 32 SEACQUAPLUSContrasted
Renova 29 SECOMPACTContrasted
Renova 20 SEECOLASERContrasted
Renova 23 SEEURAContrasted
Renova TOP 24 SEEURAContrasted
Renova 24 SEMASTERContrasted
Renova 24 SESUPERMASTERContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 2000803043 is the part for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 2000803043. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms that require diagnosis in the 3-way valve 2000803043

The 3-way valve diverts water between heating and domestic hot water. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    There is no domestic hot water even though the heating is working, or vice versa.

    Cause: The actuator does not move the valve to the correct end of the circuit and the water is not distributed properly.

    Check if the problem occurs consistently in the same mode before considering that the motor is faulty.

  • 02

    The boiler takes too long to switch modes, or it gets stuck halfway.

    Cause: The motor does not complete its cycle on time due to wear or internal gear failure.

    Time a complete change cycle and compare it with another similar unit before replacing the part.

  • 03

    A clicking or popping sound is heard when trying to switch modes.

    Cause: The actuator gear skips without moving the valve shaft.

    Check that the actuator is properly positioned on the valve body, without any play, before replacing it.

  • 04

    The motor does not turn at all and the gas valve is stuck.

    Cause: The motor is not receiving power or the gear is completely jammed.

    Check if there is power to the actuator at the moment of the change order before replacing the part.

Renova fault codes that require diagnosis

CodeFaultTechnical checks
F.318The 3-way motorised valve is not moving.The actuator (motor) of the V3V is faulty, disconnected, or jammed, so the electronics do not detect movement. Check from the actuator test in the service menu and/or by measuring continuity/power supply to the motor and inspecting the connector.
F.326The hydraulic test of the sensor and the actuator has determined that at least two hydraulic components are not functioning.The V3V is blocked (actuator locked or stuck), so the self-test detects a lack of movement. Check in service test the movement/sound of the V3V and that the actuator receives voltage; if it does not operate, replace the actuator motor.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the 3-way valve Renova 2000803043

Catalogue reference
2000803043
Uniclima internal SKU
EVVCRS30SE
Brand
Renova
Type of part
3-way valves
Units in stock
3 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

Manufacturer code
VC6012
Voltage
200-240 VAC 50/60 Hz
Consumption
6 VA
Race time
6 SEC
IP Protection
IP40
Temperature class
T65 TS110
Insulation
Double insulation (Class II)
Manufactured in
Canada
Frequently Asked Questions

Frequently asked questions about the 3-way valve 2000803043

Is this Honeywell VC6012 motor suitable for the ACQUAPLUS 29 SE boiler?
Yes, ACQUAPLUS 29 SE is on the list of boilers compatible with this actuator.
Who manufactures the actuator motor for the 3-way valve of the EURA TOP 24 SE?
Honeywell, model VC6012, according to the part label.
What fault indicates that the VC6012 actuator needs to be replaced in a MASTER 24 SE?
The motor does not turn, makes noise, or the valve gets stuck halfway between heating and domestic hot water.
How long does the VC6012 actuator take to move the 3-way valve of the SUPERMASTER 24 SE?
6 seconds, with a consumption of 6 VA, according to the motor label.
Entrega calculada por destino Delivery time shown at checkout
1-year warranty reviewed and tested
14-day return uninstalled parts