IMEBUR Gas Pressure Regulator for Victoria 20/20 F Boiler
Gas pressure regulating valve that supplies the boiler burner. The part has the 'R-20' mark cast into the housing and is manufactured by IMEBUR, as identified on the label. Compatible with Laura, Nora, Sara, and Victoria boilers from the specified range. It is replaced when there is a failure in the supply or regulation of gas to the burner.
VAT included
Consult via WhatsAppBaxi Roca boilers compatible with reference 122152870
Gas valve with reference 122152870. Nine confirmed compatibilities: Victoria 20 GN and Victoria 20/20 GN.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Baxi Roca Victoria 20 GN | Baxi Roca Victoria | Contrasted |
| Baxi Roca Victoria 20/20 GN | Baxi Roca Victoria | Contrasted |
| Baxi Roca Victoria 20/20 F GN | Baxi Roca Victoria | Contrasted |
| Baxi Roca Victoria 20/20 T GN | Baxi Roca Victoria | Contrasted |
| Baxi Roca Laura 20 GN | Baxi Roca Laura | Contrasted |
| Baxi Roca Laura 20 F GN | Baxi Roca Laura | Contrasted |
| Baxi Roca Laura 20/20 F GN | Baxi Roca Laura | Contrasted |
| Baxi Roca Laura 20/20 GN | Baxi Roca Laura | Contrasted |
| Baxi Roca Laura Plus 28/28 GN | Baxi Roca Laura | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. 122152870 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 122152870. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the gas valve 122152870 resolves
The gas valve regulates and modulates the gas flow to the burner. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler does not ignite or gets locked when trying to start it, without reaching a flame.
Cause: If the regulator does not allow the correct gas pressure to pass, the flame does not ignite and the boiler locks out for safety.
Check that the main gas valve is fully open and that there are no faults in other gas appliances in the house before inspecting the regulator.
- 02
The flame is unstable, moving a lot or changing color, appearing more yellow than usual.
Cause: An irregular gas pressure causes either excess or insufficient gas to reach the burner.
Observe the flame through the sight glass; if it fluctuates without reason with the boiler at a single power level, the problem may be with the regulator.
- 03
The boiler does not modulate: it always delivers the same power, regardless of what the thermostat or the tap requests.
Cause: The regulator adjusts the gas pressure according to the signal from the PCB; if it gets stuck, the flame remains fixed.
Request different demands, for example, open a tap fully and then almost close it, and check if the flame size changes.
- 04
A slight smell of gas is detected near the boiler.
Cause: A damaged internal gasket or membrane of the regulator can allow gas leakage, even if it's in small amounts.
If you smell gas, turn off the shut-off valve and ventilate before continuing to check: it is not safe to check with the boiler on.
Fault codes for Baxi Roca that this part resolves.
| Code | Fault | Diagnosis and solution |
|---|---|---|
| 40-70-90 | Power failure in gas solenoid valve. | The gas block/valve assembly (regulator 122152870) does not open because the coil is open, without power, or with a loose connector; the boiler locks out. Check coil continuity and voltage at the connector according to the manual, and ensure there is gas in the manifold with a manometer. |
| 60-70-90 | Ignition lockout. | If the regulator/gas valve 122152870 does not supply gas (low pressure or solenoids not opening), no flame is formed and the PCB locks out. Check the inlet pressure NG ≈20 mbar during the start-up attempt and verify the operation/power supply of the solenoids. |
| 40-80-90 | Lack of gas during operation or a total or partial electrical fault. | Loss of flame detection during operation due to gas supply cut/intermittence: unstable regulator, coil dropping when hot, or electrical fault in the gas block. Check voltage stability at the valve, load pressure, and regulator modulation. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Baxi Roca gas valve 122152870
- Catalogue reference
- 122152870
- Brand
- Baxi Roca
- Type of part
- Gas valves
- Units in stock
- 3 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Manufacturer
- IMEBUR
- Brand embossed on casing
- R-20
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Baxi Roca Victoria 20/20 GN Manual (PDF)Document © Baxi Roca, provided as a technical reference.