When the heating starts, the Honeywell gas valve for Saunier Duval Thema F and Glow-Worm GW 24CI is responsible for regulating and allowing the flow of gas to the burner. If this part fails, you will notice that the boiler does not ignite, there may be flame lockouts, or a malfunction in gas modulation. This valve is compatible with several models, such as Themafast C 24 E, Themaclassic F 24 E, and Themaplus F 25 E, among others. It is recommended to replace it if you experience faults such as F.26, F.27, or F.62.

Compatibility

Saunier Duval boilers compatible with reference S1071400

Gas valve with reference S1071400. 24 verified compatibilities: Themafast C 24 E and Themafast C 25 E.

Proven compatibility

Boiler modelFamilyVerification
Saunier Duval Themafast C 24 EThemafastContrasted
Saunier Duval Themafast C 25 EThemafastContrasted
Saunier Duval Themafast F 24 EThemafastContrasted
Saunier Duval Themafast F 25 EThemafastContrasted
Saunier Duval Themaclassic C 24 EThemaclassicContrasted
Saunier Duval Themaclassic C 25 EThemaclassicContrasted
Saunier Duval Themaclassic F 24 EThemaclassicContrasted
Saunier Duval Themaclassic F 25 EThemaclassicContrasted
Saunier Duval Themaplus C 24 EThemaplusContrasted
Saunier Duval Themaplus F 24 EThemaplusContrasted
Saunier Duval Themaplus F 25 EThemaplusContrasted
Saunier Duval Thema C 24 EThemaContrasted
Saunier Duval Thema F 24 EThemaContrasted
Saunier Duval Thema F 25 EThemaContrasted
Saunier Duval Thematek C 24 EThematekContrasted
Saunier Duval Thematek F 24 EThematekContrasted
Saunier Duval Isofast F 30 E H-MODIsofastContrasted
Saunier Duval Isofast F 35 E H-MODIsofastContrasted
Saunier Duval Isosplit C 28 EIsosplitContrasted
Saunier Duval Isosplit F 30 EIsosplitContrasted
Saunier Duval Isosplit F 35 EIsosplitContrasted
Saunier Duval Opalia C 16 EOpaliaContrasted
Saunier Duval Opalia F 14 EOpaliaContrasted
Saunier Duval Opaliaplus F 17 EOpaliaContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. S1071400 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference S1071400. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the gas valve S1071400 resolves.

The gas valve regulates and modulates the gas flow to the burner. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not ignite, or it makes several attempts before lighting.

    Cause: The valve does not open the gas flow to the main solenoid, or the electromagnet does not receive the opening command properly.

    Measure with a multimeter that there is power reaching the connectors of the gas valve before declaring it faulty.

  • 02

    The flame modulates with fluctuations: it rises and falls in power for no apparent reason.

    Cause: The modulation actuator of the gas valve does not properly regulate the gas flow to the burner.

    Clean the flame sensor and check the heat exchanger before attributing the fault to the gas valve: poor combustion produces the same symptoms.

  • 03

    There is a smell of gas near the boiler, or a loss of tightness is noticeable.

    Cause: An internal gasket of the gas valve has lost tightness and allows gas to pass even when it is in the closed position.

    Locate the exact point with soapy water in the connections before assuming that the leak is coming from the gas valve.

  • 04

    An error code related to the flame or gas supply appears on the display.

    Cause: The control unit detects that the gas valve does not respond to the opening or closing command and locks for safety.

    Note the exact code and check it in the boiler manual to confirm that it points to the gas valve and not to the electrode or the ionization sensor.

Fault codes from Saunier Duval that this spare part resolves.

CodeFaultDiagnosis and solution
F.26Fault: gas valve not functioning.The Honeywell gas valve S1071400 does not open because the stepper motor/solenoids do not receive or do not respond to the command. Check the connector/harness, coil continuity, and ensure that the valve is powered during the ignition attempt; also check that there is no pressure at the outlet during the attempt.
F.27Safety shutdown: flame simulation.Defective/leaky gas valve S1071400 allows gas to pass when it should be closed, simulating a flame. Check tightness and closure: perform a pressure drop test at the burner inlet and confirm that ionisation ceases when the gas is cut off.
F.28Start-up fault: ignition failed.The gas valve S1071400 does not open or is poorly calibrated, preventing the gas supply during ignition. Check that the electronics command opening (voltage to coils) and that pressure appears at the outlet during the attempt; if it does not open or is erratic, replace/adjust.
F.61Fault: gas valve control.Electrical defect in valve S1071400 (coil short-circuited/grounded) or in its wiring causes activation fault. Check coil resistance/insulation and continuity of the harness to the PCB; if there is a ground leak or values are out of range, replace the valve.
F.62Gas valve fault. Disconnection delay.The S1071400 valve takes time to close or remains unsealed, maintaining gas after the stop command. Check closing time and tightness (pressure/ionisation test after cut-off); if gas or residual flame persists, replace the valve.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Saunier Duval gas valve S1071400.

Catalogue reference
S1071400
Brand
Saunier Duval
Type of part
Gas valves
Units in stock
0 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Modulating coil voltage
24 VDC
Modulating coil power
6 VA
Type of gas
NATURAL GAS
Protection
IP 20
Solenoid voltage V1
22 Vdc (4VA)
Solenoid voltage V2
24 Vdc (6VA)
Maximum pressure
P.max 60 mbar
Equivalent model (Honeywell)
VK8525M1003
Frequently Asked Questions

Frequently asked questions about the gas valve S1071400

Does this gas valve work for my Glow-Worm GW 24CI boiler?
Yes, the GW 24CI is on the list of compatible boilers, along with other models from the Themafast, Themaclassic, Themaplus, Thema, Thematek, Isofast, Isosplit, and Opalia ranges.
How many solenoids does the gas valve of the Isofast F 30 EH have?
It has two: a solenoid V1 of 22 VDC (4VA) and another V2 of 24 VDC (6VA), plus a modulating coil of 24 VDC / 6VA.
What fault does replacing this gas valve in a Thema F 24 E resolve?
It is replaced when the boiler does not ignite or loses tightness.
What gas does the valve of the Opalia C 16 E use?
According to the label of the part, natural gas (GAZ NATUREL).
How many models are compatible with the Honeywell VGTSF24E gas valve?
A total of 24 models are compatible.
What fault codes are documented for this gas valve?
The documented fault codes are F.26, F.27, F.28, F.61, and F.62.