Honeywell Gas Valve Saunier Duval ThemaClassic C 25 E Ref. S1071500

Honeywell Gas Valve Saunier Duval ThemaClassic C 25 E Ref. S1071500

Stock · 4 units

Honeywell gas valve (own code 4000 124 246 1) for Saunier Duval boilers in the Thema, ThemaClassic, ThemaFast, and Isofast range. It controls the flow of natural gas to the burner through two coils (22 Vdc/4VA and 24 Vdc/6VA), class B+B. It is replaced when the boiler does not receive gas, does not ignite, or shows a gas valve fault.

VAT included

Compatibility

Saunier Duval boilers compatible with reference S1071500

Gas valve with reference S1071500. 28 verified compatibilities: C24E and C25E.

Proven compatibility

Boiler modelFamilyVerification
Saunier Duval C24EThemafastContrasted
Saunier Duval C25EThemafastContrasted
Saunier Duval C28EThemafastContrasted
Saunier Duval C30EThemafastContrasted
Saunier Duval F24EThemafastContrasted
Saunier Duval F25EThemafastContrasted
Saunier Duval F25E H-MODThemafastContrasted
Saunier Duval F30EThemafastContrasted
Saunier Duval F30E H-MODThemafastContrasted
Saunier Duval C24EThemaclassicContrasted
Saunier Duval C25EThemaclassicContrasted
Saunier Duval F24EThemaclassicContrasted
Saunier Duval F25EThemaclassicContrasted
Saunier Duval F AS 24EThemaclassicContrasted
Saunier Duval F AS 25EThemaclassicContrasted
Saunier Duval F AS 30EThemaclassicContrasted
Saunier Duval C24EThematekContrasted
Saunier Duval F24EThematekContrasted
Saunier Duval F30E H-MODIsofastContrasted
Saunier Duval F35E H-MODIsofastContrasted
Saunier Duval C16EOpaliaContrasted
Saunier Duval F11EOpaliaContrasted
Saunier Duval F14EOpaliaContrasted
Saunier Duval F17EOpaliaContrasted
Saunier Duval C24EThemaContrasted
Saunier Duval C25EThemaContrasted
Saunier Duval F24EThemaContrasted
Saunier Duval F25EThemaContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. S1071500 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference S1071500. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the gas valve S1071500 resolves.

The gas valve regulates and modulates the gas flow to the burner. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not ignite or locks out due to flame failure right after starting.

    Cause: If either of the two coils of the gas valve does not receive or maintain the necessary current, the gas flow does not open in time.

    Check that power is reaching both connectors of the gas valve at the moment of ignition before replacing it.

  • 02

    Gas is not reaching the burner even though the boiler is trying.

    Cause: A mechanical failure in the valve shutter prevents the gas from passing even though the coils are receiving current.

    Check that the main gas valve is fully open and that there is no air left in the line after a recent intervention.

  • 03

    The display shows a gas valve fault code or warning.

    Cause: The control unit compares the signal from the coils with the expected value and indicates a fault when it detects a difference.

    Note the exact code: if it appears consistently at the same point in the ignition cycle, it is a more reliable indication than if it appears randomly.

  • 04

    The boiler ignites but stops shortly after, as if it loses the flame.

    Cause: One of the two coils may fail intermittently when it heats up, shutting off the gas flow after a few seconds of operation.

    Check if the cut always takes the same time to appear: this points more to a component that heats up and fails, like this gas valve.

Fault codes from Saunier Duval that this spare part resolves.

CodeFaultDiagnosis and solution
F1Ignition fault.The gas block S1071500 does not open or is misaligned and does not provide flow during the spark attempt; check with a manometer at the valve ports (inlet/outlet) and measure voltage/continuity in coils during startup.
F.28Start-up fault: ignition failed.Fault in the gas valve assembly (block S1071500) or in its stepper motor prevents opening/modulating the gas during startup; check flow pressure and valve operation (measurement at ports and coil supply) during the ignition attempt.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Saunier Duval gas valve S1071500.

Catalogue reference
S1071500
Brand
Saunier Duval
Type of part
Gas valves
Units in stock
4 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

manufacturer
Honeywell
manufacturer code (Honeywell)
4000 124 246 1
coil V1 (voltage/power)
22 Vdc / 4 VA
coil V2 (voltage/power)
24 Vdc / 6 VA
gas
Natural gas (GAZ NATUREL)
IP protection
IP 20
class
B+B, Group 1
manufacturing date (label)
07/8/09
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the gas valve S1071500

Is this gas valve Ref. S1071500 suitable for a Saunier Duval ThemaClassic C 25 E?
Yes, the ThemaClassic C 25 E is on the list of boilers compatible with this gas valve.
Who manufactures the gas valve S1071500 used in the Saunier Duval Thema C 24 E?
The Honeywell factory; it is sold as a spare part for Saunier Duval boilers.
What fault indicates that this valve needs to be changed in an Isofast F 30 E?
It is replaced when the boiler does not receive gas, does not ignite, or shows a gas valve fault.
What voltage do the coils of this valve operate at in the THEMACLASSIC F 24 E?
24 Vdc, with two coils: 22 Vdc/4VA and 24 Vdc/6VA, class B+B.

Spare parts related to Saunier Duval Themafast

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Honeywell Gas Valve Saunier Duval ThemaClassic C 25 E Ref. S1071500