Honeywell Gas Valve VK8115F - Thema Condens F24E - Ref. 0020018436
Gas valve manufactured by Honeywell, model VK8115F, made in the Netherlands. It operates at 24 V AC with a consumption of 0.42 A and a maximum pressure of 60 mbar (category III, class B+C). It regulates the gas flow to the boiler burner. It is replaced when the boiler does not ignite, locks up on startup, or shows a flame failure due to lack of gas.
VAT included
Consult via WhatsAppSaunier Duval boilers compatible with reference 0020018436
Gas valve with reference 0020018436. Four confirmed compatibilities: Themafast Condens F30 and Themafast Condens F30E.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Saunier Duval Themafast Condens F30 | Themafast Condens | Contrasted |
| Saunier Duval Themafast Condens F30E | Themafast Condens | Contrasted |
| Saunier Duval Themafast Condens F24E | Themafast Condens | Contrasted |
| Saunier Duval Thema Condens F24E | Thema Condens | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. 0020018436 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 0020018436. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the gas valve 0020018436 resolves.
The gas valve regulates and modulates the gas flow to the burner. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler does not ignite or the flame does not start.
Cause: The gas valve does not allow gas to flow to the burner even though the control board commands the ignition.
Check that the main gas valve is open and that the pressure of the installation is correct before considering the gas valve.
- 02
Boiler lockout when attempting to ignite
Cause: The valve opens with a delay or incompletely, and the electrode does not detect the flame in time.
Check the fault code on the display: if it indicates a flame failure on the first attempt, first rule out the ionization electrode and its wiring.
- 03
Intermittent flame failure due to gas cut-off
Cause: The gas valve does not maintain a stable gas flow and the flame goes out by itself.
Check if the cut coincides with power changes when modulating; if it always happens at those times, check the gas pressure sensor first.
- 04
The boiler does not modulate the flame power properly.
Cause: The modulating solenoid of the gas valve does not regulate the gas flow correctly according to demand.
Check if the flame changes abruptly from minimum to maximum without intermediate steps; a jumpy modulation, rather than a progressive one, indicates a problem with the gas valve.
Fault codes from Saunier Duval that this spare part resolves.
| Code | Fault | Diagnosis and solution |
|---|---|---|
| F.26 | Fault: gas valve not functioning. | The stepper motor/coils of the valve do not operate or are disconnected, so it does not open/modulate. Check the continuity of the coils, connector, and harness up to the PCB and ensure it receives voltage in test P.0. |
| F.27 | Safety shutdown: incorrect flame detection. | The sealed gas solenoid valve may allow gas to pass when it should be closed, causing an implausible flame signal. Check the valve's tightness/closure and absence of flame with the gas cut off. |
| F.28 | Start-up fault: ignition failed. | Among the causes is an incorrect/faulty gas valve that does not open or supply flow. Check inlet pressure, that the valve is the correct reference, activation signal, and pressure/output during the ignition attempt. |
| F.56 | Fault in the regulation of the circulating flow sensor. | The manual associates this fault with a faulty gas valve or its wiring harness, so a defective valve may cause incorrect flow/mix reading/regulation. Check the valve and wiring; if it reappears after adjustment, replace the valve. |
| F.61 | Gas valve control fault. | The PCB detects that it cannot activate the valve (coils grounded/cut). Check insulation and resistance of coils, continuity of the harness, and control output from the electronics. |
| F.62 | Gas valve fault. Disconnection delay. | The valve sticks or leaks and takes time to close after the flame extinguishes. Check that the flame signal drops when the gas is cut and the valve's tightness/quick closure; replace if there is a delay/leak. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the gas valve Saunier Duval 0020018436
- Catalogue reference
- 0020018436
- Brand
- Saunier Duval
- Type of part
- Gas valves
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Component manufacturer
- Honeywell
- code
- VK8115F
- voltage
- 24 Vrac
- current
- 0.42 A
- Max pressure
- 60 mbar, CAT III, Class B+C
- Country of manufacture
- Netherlands (Made in the Netherlands)
- CE marking
- CE-00E8AP3S90/6 (characters with reflection, not very clear in the photo)
- Ambient temperature
- "+12°C to -20°C" as printed; the order is unusual and it could be a faulty reading of "-12°C to +20°C", it is not corrected.
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Saunier Duval Themafast Condens F24E Manual (PDF)Document © Saunier Duval, provided as a technical reference.