Honeywell VK8525M Gas Valve for Saunier Duval Themafast F 24 E - Ref. S1071400

Honeywell VK8525M Gas Valve for Saunier Duval Themafast F 24 E - Ref. S1071400

Stock · 5 units

Honeywell VK8525M gas valve. It is the component that regulates the flow of gas to the burner, controlled by the selector coils according to the demand of the boiler. It is replaced when the boiler does not ignite, shows a gas valve fault, or a leak is suspected in the body of the valve. Actual manufacturer is Honeywell, different from the boiler brand Saunier Duval.

VAT included

Compatibility

Saunier Duval boilers compatible with reference S1071400

Gas valve with reference S1071400. 24 verified compatibilities: Themafast C 24 E and Themafast C 25 E.

Proven compatibility

Boiler modelFamilyVerification
Saunier Duval Themafast C 24 EThemafastContrasted
Saunier Duval Themafast C 25 EThemafastContrasted
Saunier Duval Themafast F 24 EThemafastContrasted
Saunier Duval Themafast F 25 EThemafastContrasted
Saunier Duval Themaclassic C 24 EThemaclassicContrasted
Saunier Duval Themaclassic C 25 EThemaclassicContrasted
Saunier Duval Themaclassic F 24 EThemaclassicContrasted
Saunier Duval Themaclassic F 25 EThemaclassicContrasted
Saunier Duval Themaplus C 24 EThemaplusContrasted
Saunier Duval Themaplus F 24 EThemaplusContrasted
Saunier Duval Themaplus F 25 EThemaplusContrasted
Saunier Duval Thema C 24 EThemaContrasted
Saunier Duval Thema F 24 EThemaContrasted
Saunier Duval Thema F 25 EThemaContrasted
Saunier Duval Thematek C 24 EThematekContrasted
Saunier Duval Thematek F 24 EThematekContrasted
Saunier Duval Isofast F 30 E H-MODIsofastContrasted
Saunier Duval Isofast F 35 E H-MODIsofastContrasted
Saunier Duval Isosplit C 28 EIsosplitContrasted
Saunier Duval Isosplit F 30 EIsosplitContrasted
Saunier Duval Isosplit F 35 EIsosplitContrasted
Saunier Duval Opalia C 16 EOpaliaContrasted
Saunier Duval Opalia F 14 EOpaliaContrasted
Saunier Duval Opaliaplus F 17 EOpaliaContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. S1071400 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference S1071400. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the gas valve S1071400 resolves.

The gas valve regulates and modulates the gas flow to the burner. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not ignite because there is no gas, although you can hear it trying to start.

    Cause: The gas valve selector does not open and the burner does not receive fuel when ignited.

    Check that the gas supply valve to the boiler is open and that other gas appliances in the house are working properly.

  • 02

    The display shows a fault or blockage of the gas valve repeatedly.

    Cause: The control unit does not detect that the selector opens in time and locks the equipment for safety.

    Note the exact code and consult the manual: some gas valve codes may first indicate the pressure switch or the electrode, not the valve.

  • 03

    There is a smell of gas or a suspected leak in the body of the gas valve.

    Cause: The body of the VK8525M gas valve may lose tightness over time and allow gas to escape.

    Do not turn on or off switches nearby, ventilate, and turn off the gas valve before a technician confirms the source of the smell.

  • 04

    The ignition is intermittent: sometimes it lights on the first try and other times it takes several attempts.

    Cause: One of the valve selectors does not consistently close the contact, and gas reaches the burner irregularly.

    Check if the fault worsens with the boiler cold and just started up, as this helps to differentiate a gas valve problem from an ignition electrode issue.

Fault codes from Saunier Duval that this spare part resolves.

CodeFaultDiagnosis and solution
F.26Fault: gas valve not functioning.The Honeywell gas valve S1071400 does not open because the stepper motor/solenoids do not receive or do not respond to the command. Check the connector/harness, coil continuity, and ensure that the valve is powered during the ignition attempt; also check that there is no pressure at the outlet during the attempt.
F.27Safety shutdown: flame simulation.Defective/leaky gas valve S1071400 allows gas to pass when it should be closed, simulating a flame. Check tightness and closure: perform a pressure drop test at the burner inlet and confirm that ionisation ceases when the gas is cut off.
F.28Start-up fault: ignition failed.The gas valve S1071400 does not open or is poorly calibrated, preventing the gas supply during ignition. Check that the electronics command opening (voltage to coils) and that pressure appears at the outlet during the attempt; if it does not open or is erratic, replace/adjust.
F.61Fault: gas valve control.Electrical defect in valve S1071400 (coil short-circuited/grounded) or in its wiring causes activation fault. Check coil resistance/insulation and continuity of the harness to the PCB; if there is a ground leak or values are out of range, replace the valve.
F.62Gas valve fault. Disconnection delay.The S1071400 valve takes time to close or remains unsealed, maintaining gas after the stop command. Check closing time and tightness (pressure/ionisation test after cut-off); if gas or residual flame persists, replace the valve.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Saunier Duval gas valve S1071400.

Catalogue reference
S1071400
Brand
Saunier Duval
Type of part
Gas valves
Units in stock
5 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Manufacturer
Honeywell
Valve model
Honeywell VK8525M
Visible regulatory marking
EAC (Eurasian marking, not CE)
Maximum pressure
60 mbar
Voltage V1
22 Vdc (4VA)
Voltage V2
24 Vdc (6VA)
Class
Group 1 / Class B+B
Natural gas selector coil voltage
24 VDC / 6 VA
Coil reference
4000 124 246 1
Date/batch of the coil
060/18
Before purchasing
  • The actual manufacturer of the valve is Honeywell, not Saunier Duval.
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the gas valve S1071400

Is the VK8525M gas valve Ref. S1071400 an original part from Saunier Duval?
No; the actual manufacturer is Honeywell, model VK8525M, although Saunier Duval installs it as original equipment in these boilers.
Does this valve VK8525M fit a Saunier Duval Thema F 25 E?
Yes, the Thema F 25 E is on the list of compatible boilers.
What fault indicates that this valve needs to be changed in an Isofast F 30 E?
It is replaced when the boiler does not ignite, shows a gas valve fault, or a leak is suspected in the valve body.
What is the consumption of the gas selector coil of the VK8525M valve?
6 VA, operating at 24 VDC.

Spare parts related to Saunier Duval Themafast

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Honeywell VK8525M Gas Valve for Saunier Duval Themafast F 24 E - Ref. S1071400