Bertelli & Partners Ignition and Flame Detection Control Unit B 038 P 1 Ref. 011183
Ignition and flame detection control unit for Immergas boilers Avio, Eolo, Iono, Maior, Nike, and Zeus. Manufactured by Bertelli & Partners, with engraved code I.011183. Operates at 235 V 50 Hz and includes a fuse F3.15A 250V MAX. It is replaced when the boiler's ignition or flame detection fails.
VAT included
Consult via WhatsAppImmergas boilers compatible with reference 011183
PCB with reference 011183. Six confirmed compatibilities: AVIO and EOLO.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Immergas AVIO | AVIO | Contrasted |
| Immergas EOLO | EOLO | Contrasted |
| Immergas IONO | IONO | Contrasted |
| Immergas MAIOR | MAIOR | Contrasted |
| Immergas NIKE | NIKE | Contrasted |
| Immergas ZEUS | ZEUS | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. 011183 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 011183. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the PCB 011183 resolves.
The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler tries to ignite, you can hear the spark, but the flame doesn't catch.
Cause: The control board manages the ignition and may fail to generate or maintain the spark at the electrode.
Check the condition and distance of the ignition electrode and the spark plug wire before replacing the control unit.
- 02
The flame ignites but goes out after a few seconds and the boiler locks out.
Cause: The control unit does not properly detect the flame ionization signal and shuts off the gas for safety.
Clean and inspect the flame detection electrode and its cable; a dirty or improperly positioned one can cause the same symptom.
- 03
The boiler repeatedly locks out and needs to be manually reset frequently.
Cause: A fault in the control unit's management of the ignition cycle causes lockouts that can only be resolved with a manual reset.
Check the boiler's grounding; poor grounding causes blockages identical to those of a faulty control unit.
- 04
No ignition spark occurs when starting the boiler.
Cause: The control unit is not sending the high voltage signal to the ignition electrode.
Check that the fuse on the control unit is intact before replacing the entire part.
Fault codes from Immergas that this part resolves.
| Code | Fault | Diagnosis and solution |
|---|---|---|
| E14 | Fault in the flame control board. | This ignition/flame detection control board (1.011183) manages the spark and ionisation; if it fails, the boiler detects a flame control anomaly and displays E14. Check the ionisation signal and the power supplies/connections of the control board; if the signal is null or unstable, replace the control board. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Technical data sheet for the Immergas PCB 011183.
- Catalogue reference
- 011183
- Brand
- Immergas
- Type of part
- PCBs (control boards)
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Manufacturer
- Bertelli & Partners
- Recorded code
- I.011183
- Voltage / Frequency
- 235 V 50 Hz
- Fuse
- F3.15A 250V MAX
- Secondary code on label
- 01.101499.01
- Certification
- REG CE 51AQ877