Bertelli & Partners Immergas Eolo Maior PCB Ref. MLC09

The Bertelli & Partners Immergas Eolo Maior PCB is the component that controls the ignition, burner modulation, pump, and safety features of the boiler. When it malfunctions, the boiler may fail to start, lock out, or operate erratically, and the fault code E04 may appear. This board is compatible with the models Eolo 21 Maior, Eolo 21 Maior S, Eolo 24 Maior, Eolo 24 Maior S, Eolo 27 Maior, as well as some models from the Zeus Maior and Extra ranges. A technician must confirm through diagnosis whether the board needs to be replaced when these malfunction symptoms occur.

Catalogue reference
024985
Warranty
1 year
VAT included Stock · 1 unit
Compatibility

Immergas boilers compatible with reference 024985

PCB with reference 024985. 12 verified compatibilities: Eolo 21 Maior @ and Eolo 21 Maior S @.

Proven compatibility

Boiler modelFamilyVerification
Immergas Eolo 21 Maior @Eolo MaiorContrasted
Immergas Eolo 21 Maior S @Eolo MaiorContrasted
Immergas Eolo 24 Maior @Eolo MaiorContrasted
Immergas Eolo 24 Maior S @Eolo MaiorContrasted
Immergas Eolo 27 Maior @Eolo MaiorContrasted
Immergas Zeus 21 MaiorZeus MaiorContrasted
Immergas Zeus 24 MaiorZeus MaiorContrasted
Immergas Extra @ CSExtraContrasted
Immergas Extra @ TFExtraContrasted
Immergas Extra Intra 20ExtraContrasted
Immergas Extra Intra 24ExtraContrasted
Immergas Extra MiniExtraContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 024985 is the part for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 024985. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms that require diagnosis on the PCB 024985

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler shows no signs of life, neither indicators nor display.

    Cause: The fuse on the PCB has blown and cuts off power to the entire control circuit.

    Check the fuse F 315A/250V with the multimeter for continuity, or look at it in the light to see if the wire is broken, before replacing the entire PCB.

  • 02

    The fuse blows again immediately after replacing it.

    Cause: There is a short circuit in some component of the PCB that continues to cause excessive consumption.

    If the new fuse blows immediately, do not insist on changing it multiple times: it is a sign that the fault is in the PCB.

  • 03

    The boiler ignites, makes some strange noise in the area of the PCB, and shuts down after a few seconds.

    Cause: The control board detects an internal anomaly and cuts off the ignition for safety.

    Note if the cut always coincides with the same point in the ignition cycle; it helps to distinguish a fault in the PCB from one in the burner or the gas valve.

  • 04

    The indicators are flashing in a sequence that does not appear in the user manual.

    Cause: The PCB is displaying a fault code specific to its control electronics, not always documented for the end user.

    Take a photo of the blinking sequence and consult it with a technician or the service manual before deciding to change the PCB.

  • 05

    The boiler responds slowly to commands or takes a long time to start the burner.

    Cause: A fault in the control circuit of the PCB slows down the processing of the ignition signals.

    Check that the gas and the pressure of the installation are correct before attributing the delay to the PCB, as a supply issue can also cause it.

Immergas fault codes that require diagnosis

CodeFaultTechnical checks
E04Generic anomaly of the boiler PCB.Internal fault of the ignition/modulation board or detection by the PCB of an anomaly in the power supply to the gas valve; check voltages/continuity from the board to the valve and, if peripherals are correct, replace the board.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Immergas PCB 024985

Catalogue reference
024985
Uniclima internal SKU
PECIEM0501
Brand
Immergas
Type of part
PCBs (control boards)
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

Fuse
F 315A 250V
Silkscreen code on the PCB
MLC09
Manufacturer (main chip)
Bertelli & Partners
Frequently Asked Questions

Frequently asked questions about the PCB 024985

Is the MLC09 PCB compatible with an Immergas Zeus 24 Maior?
Yes, the Zeus 24 Maior is on the list of boilers compatible with this PCB.
What fuse does the Bertelli & Partners PCB of the Eolo Maior use?
Install a F 315A 250V fuse.

Spare parts related to Immergas Eolo Maior

Entrega calculada por destino Delivery time shown at checkout
1-year warranty reviewed and tested
14-day return uninstalled parts
Technical support we verify your model