Fagor Super Compact FE 24 EMA PCB Ref. N03A000A2

Fagor Super Compact FE 24 EMA PCB Ref. N03A000A2

Stock · 4 units

Fagor control board for Super Compact FE-24/27/35 EMA and FEE-24/26/27/35/40 MA boilers. Reference N03A000A2, with main integrated circuit 7709324.000 MACU1024. The manufacturer Fagor is confirmed by the label and external sources. It is replaced when the ignition control fails or there is an electronic fault in the boiler.

VAT included

Compatibility

Fagor boilers compatible with reference N03A000A2

PCB with reference N03A000A2. Nine confirmed compatibilities: FE-24EMA and FE-27EMA.

Proven compatibility

Boiler modelFamilyVerification
Fagor FE-24EMAFagor Supercompact (EMA range)Contrasted
Fagor FE-27EMAFagor Supercompact (EMA range)Contrasted
Fagor FE-35EMAFagor Supercompact (EMA range)Contrasted
Fagor FEE-24MAFagor Isocomfort / MA seriesContrasted
Fagor FEE-26MAFagor Isocomfort / MA seriesContrasted
Fagor FEE-27MAFagor Isocomfort / MA seriesContrasted
Fagor FEE-35MAFagor Isocomfort / MA seriesContrasted
Fagor FEE-40MAFagor Isocomfort / MA seriesContrasted
Fagor FEE-35PLFagor Isocomfort / MA seriesContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. N03A000A2 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference N03A000A2. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the PCB N03A000A2 resolves.

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not ignite: it tries to start but the flame does not catch.

    Cause: The PCB manages the ignition and, if it fails, it does not send the command to ignite the flame.

    Check for spark attempts; if there are none, inspect the power supply to the boiler.

  • 02

    The display shows a fault code related to the PCB or electronic control.

    Cause: The electronics detect an internal problem and display it as a warning on the screen.

    Note the exact code: many control board warnings may indicate a sensor or external component, not the PCB.

  • 03

    It lights up well sometimes and other times it doesn't, without a fixed pattern.

    Cause: An intermittent fault in the control electronics causes inconsistent responses when starting.

    Turn off the boiler from the main switch for a couple of minutes and then turn it back on; if the fault changes, it is more likely to be the PCB.

  • 04

    The boiler does not respond to any button on the panel.

    Cause: The PCB is not processing the commands from the remote control or the remote control has lost power.

    Check that the cable or connector between the control panel and the PCB is properly connected before replacing any components.

Fault codes for Fagor that this part resolves.

CodeFaultDiagnosis and solution
F-5Control board fault.Internal fault in the control PCB (N03A000A2) preventing equipment management. Check 230 V and secondary voltages on the board, connectors, and relays; confirm with cross-testing using an operational N03A000A2 board.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Fagor N03A000A2 PCB.

Catalogue reference
N03A000A2
Brand
Fagor
Type of part
PCBs (control boards)
Units in stock
4 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Reference printed on the PCB
N03A000A2
Brand printed on the PCB
FAGOR
Main integrated circuit code
7709324.000 MACU1024
Frequently Asked Questions

Frequently asked questions about the PCB N03A000A2

Does this Fagor N03A000A2 PCB work for the FE-27EMA or only for the FE-24EMA?
It is valid for both, as well as for FE-35EMA and the entire FEE-24/26/27/35/40 MA range.
Is it an original Fagor PCB?
Yes, the manufacturer Fagor is confirmed by the label and by external sources.
When should this PCB be replaced in the Fagor Super Compact?
When the ignition control fails or an electronic fault appears in the boiler.
What integrated circuit does the PCB N03A000A2 have?
The code 7709324.000 MACU1024, printed on the main chip.
How do I know that the reference N03A000A2 is the correct one for my boiler?
It is confirmed on the label of the PCB itself and by external sources.

Spare parts related to Fagor Fagor Isocomfort / MA series

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Fagor Super Compact FE 24 EMA PCB Ref. N03A000A2