Honeywell PCB DBM01A Ferroli Domiproject C 24
The Honeywell DBM01A PCB for the Ferroli Domiproject C 24 boiler is a device that controls the ignition, burner modulation, pump, and system safety features. When this part fails, the boiler may not start, become locked, or exhibit erratic behavior. It is installed in models such as the Domiproject C24, Domiproject F24, C32M, and F2, among other boilers in the Domiproject and Tempra ranges. It should be replaced when these fault symptoms occur.
Ferroli boilers compatible with reference I39819530
PCB with reference I39819530. Five confirmed compatibilities: Domiproject C24 and Domiproject F24.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Ferroli Domiproject C24 | Domiproject | Contrasted |
| Ferroli Domiproject F24 | Domiproject | Contrasted |
| Ferroli C32M | Domiproject | Contrasted |
| Ferroli F2 | Domiproject | Contrasted |
| Ferroli Tempra 1120 | Tempra | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. I39819530 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference I39819530. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the PCB I39819530 resolves.
The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler displays a fault code that does not clear when reset.
Cause: The PCB is responsible for the diagnosis; if there is a fault in its circuit, the error persists even if the indicated component is in good condition.
Note the exact code and first rule out the component that indicates that fault before replacing the entire PCB.
- 02
The boiler ignites, tries to operate, and stops without the control being able to do anything.
Cause: This PCB controls the ignition, modulation, and safety cut-off; an internal fault can interrupt the sequence.
Perform a complete cycle and observe at which step it stops; this helps to determine if the fault is in the PCB or in the component to which it sends the command.
- 03
The room thermostat is not communicating with the boiler.
Cause: The communication between the control and the PCB is carried out through the port of this board; if it fails, the demand is not received.
Check the connection of the control bus and, if the boiler allows it, test the direct manual mode to identify where the fault is.
- 04
A burnt smell or dark marks are detected when opening the boiler.
Cause: A damaged component on the PCB can burn out and affect the entire control unit.
Visually inspect the PCB before installing the new one; if the smell comes from another location (wiring, motor), the problem is not here.
Fault codes for Ferroli that this part resolves.
| Code | Fault | Diagnosis and solution |
|---|---|---|
| F50 | Anomaly in the control board. | A problem has been detected in the boiler's control board, which may cause faults in its operation. If the boiler does not respond correctly to commands or exhibits erratic behavior, it is possible that the PCB is faulty. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Ferroli PCB I39819530
- Catalogue reference
- I39819530
- Brand
- Ferroli
- Type of part
- PCBs (control boards)
- Units in stock
- 0 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- manufacturer
- Honeywell
- code
- DBM01A
- Serial number
- 5101851814
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Ferroli Domiproject F24 Manual (PDF)Document © Ferroli, provided as a technical reference.