Honeywell PCB for NECKAR NW24 Boiler and Compatible Models
When you open the hot water tap or turn on the heating, the Honeywell PCB for the NECKAR NW24 boiler is responsible for controlling the ignition, the modulation of the burner, and the safety features of the boiler. If this part fails, you will notice that the boiler does not start, gets locked, or exhibits erratic behavior. You may observe symptoms such as the reset button flashing at 0.5 Hz or 4 Hz, indicating problems with ionization or safety control. This PCB is compatible with several models from the Junkers Euroline range, among others. A technician must confirm through diagnosis whether it is necessary to replace it when these faults in operation are detected.
- Type of part
- PCBs (control boards)
- Status
- Refurbished
- Catalogue reference
- 87083002120
- Warranty
- 1 year
Neckar boilers compatible with reference 87083002120
PCB with reference 87083002120. 22 verified compatibilities: ZW23-1AE23 and ZW23-1AE31.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Neckar ZW23-1AE23 | Junkers Euroline ZW (combi) | Contrasted |
| Neckar ZW23-1AE31 | Junkers Euroline ZW (combi) | Contrasted |
| Neckar ZW23-1KE23 | Junkers Euroline ZW (combi) | Contrasted |
| Neckar ZW23-1KE31 | Junkers Euroline ZW (combi) | Contrasted |
| Neckar ZW24-1ELH AE23 | Junkers Euroline ZW (combi) | Contrasted |
| Neckar ZW24-1ELH AE31 | Junkers Euroline ZW (combi) | Contrasted |
| Neckar ZW28-1LHKE23 | Junkers Euroline ZW (combi) | Contrasted |
| Neckar ZW28-1LHKE31 | Junkers Euroline ZW (combi) | Contrasted |
| Neckar ZW30-1LHAE23 | Junkers Euroline ZW (combi) | Contrasted |
| Neckar ZW30-1LHAE31 | Junkers Euroline ZW (combi) | Contrasted |
| Neckar ZS23-1AE23 | Junkers Euroline ZS (heating only) | Contrasted |
| Neckar ZS23-1AE31 | Junkers Euroline ZS (heating only) | Contrasted |
| Neckar ZS23-1KE23 | Junkers Euroline ZS (heating only) | Contrasted |
| Neckar ZS23-1KE31 | Junkers Euroline ZS (heating only) | Contrasted |
| Neckar NW24-1LHAE23 | Junkers Euroline NW24 | Contrasted |
| Neckar NW24-1LHAE31 | Junkers Euroline NW24 | Contrasted |
| Neckar NW24-1LHKE23 | Junkers Euroline NW24 | Contrasted |
| Neckar NW24-1LHKE31 | Junkers Euroline NW24 | Contrasted |
| Neckar NW24/28-1LHKE23 | Junkers Euroline NW24 | Contrasted |
| Neckar NW24/28-1LHKE31 | Junkers Euroline NW24 | Contrasted |
| Neckar NW24/30-1LHAE23 | Junkers Euroline NW24 | Contrasted |
| Neckar NW24/30-1LHAE31 | Junkers Euroline NW24 | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. 87083002120 is the part for your boiler
The part reference, model, and equipment revision must be verified against the manufacturer's documentation.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 87083002120. If it is not visible, do not identify the part by its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms that require diagnosis on the PCB 87083002120
The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler does not turn on: there are no lights or display, as if it is not receiving power.
Cause: The PCB distributes power to the other components; if it fails, nothing starts.
Measure with a multimeter that 230V is reaching the input of the PCB before discarding it.
- 02
The burner stops abruptly in the middle of a cycle and does not attempt to restart.
Cause: A fault in the control electronics can interrupt the ignition command even if the other components are functioning properly.
Note the fault code displayed just before the shutdown, and indicate whether it is the PCB or another component.
- 03
The remote control or the panel does not respond to any button, even though the boiler is powered.
Cause: The PCB manages communication with the control; if the circuit fails, that dialogue is lost.
Check that the bus cable between the control and the PCB is properly connected and without breaks before replacing the PCB.
- 04
The boiler restarts by itself intermittently, as if it turns off and on without reason.
Cause: A fault in the control board causes erratic restarts by losing the reference of its own parameters.
First, rule out a voltage drop in the home's electrical installation.
Neckar fault codes that require diagnosis
| Code | Fault | Technical checks |
|---|---|---|
| Reset button flashing 0.5 Hz + LED 75 °C | During ignition: ionisation signal is detected but the burner does not ignite. | The printed circuit board (PCB 87083002120) may fail in the detection/ionisation path or be damp, causing false flame or lack of spark; check ionisation microamperage, wiring, and moisture/oxidation on the PCB before replacing it. |
| Reset button flashes at 4 Hz (four times per second) | Control/safety fault (encoder/sensors) including possible PCB defect. | Fault in the PCB (Eurotronic/PCB) in managing inputs/power supplies; check voltages at ST2 (L–N/LR–N), fuses F1/F2, and 5 V to sensors. If everything is correct and the symptom persists, replace the 87083002120. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the PCB Neckar 87083002120
- Catalogue reference
- 87083002120
- Uniclima internal SKU
- PENW24
- Brand
- Neckar
- Type of part
- PCBs (control boards)
- Units in stock
- 0 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Part data and available documentation
Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.
- voltage
- 230V~
- current
- 1 A